SERVICE MENU
28
9
(always working) or “AUTO” mode (On when the welding process is On). You will see “PMP” “AUTO”
or “ON” on display. Default mode is “AUTO”.
•
Restore default values:
“rES” (reset) script is visualized. By turning the wire speed setting knob it
will appear ON” or “OFF” scripts. To restore MIG/MAG parameters default values set ON and con-
firm by pushing “2S/4S/MMA” button (PU1).
.
9.5 MENU SERVICE EXIT
•
Menu service exit:
if You see “ESC” script please push “2S/4S/MMA” (PU1)
button to confirm
the exit from service menu and entering the normal functioning of the machine. In case of MMA confi-
guration, the service menu parameters are:
•
Hot start time :
“Hot” script is visualized. It indicates hot start duration. It is expressed in seconds.
Default value is 0,5s.
Changeable interval (0,5-2) seconds.
•
Default value restore:
“rES” (reset)script is visualized. By turning the wire speed setting knob You
will see “ON” ore “OFF” scripts. To restore MMA parameters default values set ON and confirm by
pushing “2S/4S/MMA” button (PU1).
.
9.6 WATER COOLING UNIT SERVICE MENU
The water cooling unit is enabled in Simplex 420 and Simplex 320 as default.
To enter the service menu it is necessary to push at the same time the “wire feeder” button
(PU3)
and “on/off water cooling unit” button (PU2)
, at the start of the machine until the
display turns off. By releasing the buttons it will appear “AAAA” script on the right, then You will
have to enter the password “F1M3”.
Turning the current regulation handle (EN1)
) the font will change on the display and the
choice will be confirmed by pushing “2S/4S/MMA” button (PU1)
. The confirmed font will be
replaced by “-“ font and You will be able to go on to the next font.
If the right password has been entered, at the end of this operation the unit will be enabled if it
was disabled (PMP ENA), otherwise it will be disabled (PMP dlS) if it was enabled.
In case the entered password is wrong, the script “AAAA” will appear again on display.
After this it will be necessary to stop the machine and so exit from service menu.