background image

2

1.  Labels and Symbols 

The labels on the inverter show the markings, main technical data and the 

identification of the equipment and of the manufacturer.

All material used and finished product, must meet the requirements of the current RoHS Directive

Title

Modified
Issued
Design approved
Elec. Eng. approved
Mfg. approved

Drawing No.

Sheet

Dim. in mm

Scale

Size

Revision

A4

© Copyright 2020 Power-One Italy Spa. All rights reserved. Reproduction, use or disclosure to third parties without express written authority is strictly forbidden.

Regulatory Label of REACT2-BATT

XLP.V3804.3AL

F.Falzarano

F.Del Francia

05/10/2020

G.Fiesoli

05/10/2020
05/10/2020
05/10/2020

C.Granci

AA

1/1

1:1

LABEL MATERIAL:

Refer to XLP.V3806.0 for details

LABEL CONTENT:

Fixed as shown in the picture

SIZE:

175 mm (height) x 75 mm (width)

Pantone

Process Yellow C

Process Cyan C

MODEL:

REACT BATT

2-

BATTERY UNIT

I

dc max (charge)

4.5 A

Contains Rechargeable Li-ion Battery

-  Refer to instruction manual for proper installation.
-  Do not remove the cover. No user serviceable parts inside.
-  Do not expose the unit to heating sources.
-  Do not expose the unit to direct solar irradiation.
-

s.

Do not install or operate the unit in potentially explosive

atmosphere

WARNING!

IP54

-20

55

(*)

to +

°C

-4

31

(*)

to +1

°F

V

dc max

575 V

W

hr

4.0 kWh

I

dc max (discharge)

5.6 A

V

dc operating range

170 - 575 V

(*): Out of 0 to +40 °C (+32 to +104 °F) temperature range, power derating occurs

PROTECTIVE CLASS: I

Made in Italy

A

B

A) 

Inverter/battery model

B) 

Main technical data

 ATTENTION – 

A

The labels attached to the equipment must NOT be 

removed, damaged, dirtied, hidden,etc...

In the manual, and/or in some cases on the equipment, the danger or 

attention zones are indicated by signs, labels, symbols or icons.

Symbols used in the guide and on the products

Always refer to instruction manual

General warning - Important safety 

information

Hazardous voltage

Hot surfaces

Temperature range

 

Positive and negative pole of the input voltage (DC)

Always use safety clothing and/or personal safety devices

Point of connection for grounding protection

2. Equipment Models and Components

The model of equipment to which this guide refers is REACT2-BATT.

The principal components of the REACT2-BATT are shown in the figure 

and described in the following table:

COMM.

[B]

POWER

[B]

COMM.

[A]

POWER

[A]

22

23

09

08

24

26

25

20

21

26

COMM.

[B]

POWER

[B]

COMM.

[A]

POWER

[A]

22

23

09

08

24

26

25

20

21

26

Main components

08

Battery communication connector COMM.[A]

09

Battery power connector POWER [A]

20

REACT2-BATT wall bracket

21

REACT2-BATT

22

Battery communication connector COMM.[B]

23

Battery power connector POWER [B]

24

REACT2-BATT external protective earth [B]

25

REACT2-BATT external protective earth [A]

26

REACT2-BATT wall attachment point

Содержание REACT2-BATT

Страница 1: ...he safety and installation information provided in the product manual must be read and followed The technical documentation for the product is available at the website The device must be used in the manner described in the manual If this is not the case the safety devices guaranteed by the inverter might be ineffective ...

Страница 2: ... 5 6 A Vdc operating range 170 575 V Out of 0 to 40 C 32 to 104 F temperature range power derating occurs PROTECTIVE CLASS I Made in Italy A B A Inverter battery model B Main technical data ATTENTION A The labels attached to the equipment must NOT be removed damaged dirtied hidden etc In the manual and or in some cases on the equipment the danger or attention zones are indicated by signs labels sy...

Страница 3: ...way from the Battery Do not incinerate puncture or impact the Battery System Do not solder or weld to the Battery System ATTENTION A HAZARD The hazard warnings set out below are used to indicate risks or unsafe practices that CAN cause serious injury or death DO NOT dismantle or disassemble any parts DO NOT set light to or heat DO NOT use or leave near a naked flame boiler or heated places beyond ...

Страница 4: ...country concerned In addition to the regulations in force in the Country of interest the following recommendations should be followed Store the Battery Unit in its original packing including the pallet in a dry cool well ventilated environment and away from water Do not open tamper with the original packing Do not crush deform the packing Equip the storage environment with appropriate PPE Never le...

Страница 5: ...d the battery unit that could prevent the inverter installation and restrict or block the air flow The installation must take account of any electrical devices e g lamps switches etc which must be at least 20cm from the equipment These distances must be maintained also to facilitate the circulation of the air needed to cool the unit and to facilitate the operations to install maintain hardware and...

Страница 6: ...l the required 2 holes B to mount the bracket Install the REACT2 BATT bracket 20 to the support 01 20 B B 2 xØ 9 mm STEP 1 STEP 2 Lift the REACT2 BATT up to the bracket and insert the heads of two anchor points present on the back of the battery unit into the slots on the bracket 20 LIFTING U Risk of injury due to the heavy weight of the equipment Hang up the lower part of the REACT2 BATT to the w...

Страница 7: ...o anchor points present on the back of the battery unit into the slots on the bracket 20 LIFTING U Risk of injury due to the heavy weight of the equipment Hang up the lower part of the REACT2 BATT to the wall using the two wall attachment point 26 holes diameter 11 mm 21 02 20 B B 2 xØ 9 mm STEP 1 STEP 2 Remove the caps from the battery units connectors if present To remove the battery signal conn...

Страница 8: ...nge battery will be disabled Suggested ambient temperature 5 30 C Storage temperature 20 25 C 6 months or 20 45 C 3 months Relative humidity 4 100 condensing Physical Cooling Natural Dimension H x W x D 740 mm x 490 mm x 229 mm Weight 50 kg Mounting system Wall bracket Safety Protective class I Marking CE Safety IEC 62619 UN38 3 UN3480 For more information please contact your local FIMER represent...

Отзывы: