background image

Page 3

 

 

Testing the Sprayer

 

NOTE:

 

It is VERY important for you to test your sprayer with plain 

water before actual spraying is attempted. This will enable 

you to check the sprayer for leaks without the possibility of 

losing any expensive chemicals.

 

Conditions of weather and terrain must be considered when setting the 
sprayer. Do not spray on windy days. Protective clothing must be worn 
in some cases

 

Be sure to read the chemical label(s) before application!

 

Operation

 

Your sprayer is equipped with (1) ON/OFF switch in the wire assembly 

that you hook up to your battery. The “

-

” is the “ON” position and the “o” 

is the “OFF” position for the switch. Make sure the switch is depressed 

in the “

-

” position for operation.

 

The pump is equipped with a pressure switch that is factory pre

-

set for 

it to shut off at 45 p.s.i. This switch assembly is the ‘square box’ on the 

head portion of the pump.

 

Always fill the tank 1/2 full with water first and then add the chemical 

slowly, mixing as you pour the chemical into the tank and then fill the 

rest of the way.

 

The pumping system draws solution from the tank, through the strainer/

filter and to the pump. The pump forces the solution under pressure to 

the handgun.

 

 

Activate the handgun by squeezing the handle lever

 

 

Rotating the adjustable nozzle tip on the handgun will change the 

tip pattern from a straight stream to a cone pattern (fine mist)

 

After Spraying

 

After use, fill the sprayer tank part way with water. Start the sprayer and 
allow the clear water to be pumped through the plumbing system and out 
through the spray nozzle. Refill the tank about half full with plain water 
and use FIMCO Tank Neutralizer and Cleaner and repeat cleaning 
instructions above. Flush the entire sprayer with the neutralizing/cleaning 
agent, then flush out one more time with plain water. Follow the chemical 
manufacturer’s disposal instructions of all wash or rinsing water. 

 

 

WARNING: 

Some chemicals will damage the pump valves if 

allowed to soak untreated for a length of time! ALWAYS

 

flush the 

pump as instructed after each  use. DO NOT allow chemicals to sit in 
the pump for extended times of idleness. Follow the chemical 
manufacturer’s instructions on disposal of all waste water from the 
sprayer.

 

Winter Storage

 

Drain all water out of your sprayer, paying special attention to 

the pump, handgun and valve(s). These items are especially 

prone to damage from chemicals and freezing weather.

 

The sprayer should be winterized before storage by pumping a 

solution of RV antifreeze through the entire plumbing system. 

This antifreeze solution should remain in the plumbing system 

during the winter months. When spring time comes and you are 

preparing your sprayer for the spray season, rinse the entire 

plumbing system out, clearing the lines of the antifreeze 

solution. Proper care and maintenance will prolong the life of 

your sprayer.

 

There is a nylon shut

-

off valve on the intake line, next to the pump. It is at this 

location so you can shut off the flow of solution to access your system’s screen 
for cleaning.

 

 

Checking/Cleaning the sprayer’s filter/screen:

 

 

Start your pump and before it shuts off, reach down and Shut the nylon 
valve to the ‘Closed’ position (lever is perpendicular to the flow of fluid), 
then shut off your pump.

 

 

Unscrew the knurled nut from the shut

-

off valve, leaving the valve connect-

ed to the intake line.

 

 

Look in the nut you JUST unscrewed. There is a screen/washer there.

 

 

Remove the screen and clean as necessary. Replace when done and reas-
semble the entire assembly.

 

 

Make sure the valve is turned to the ‘Open’ position before restarting your 
pump.

 

Complete

 

1/2” Bulkhead Fitting

 

5275014

 

Отзывы: