![Fimco 5303636 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/fimco/5303636/5303636_manual_2289103006.webp)
Page 6
IMPORTANT:
Remove tank lid and be sure the tank is clean and free of any foreign material. Rinse tank out of any tank residue
before filling with water to test.
Testing the Sprayer
NOTE:
It is VERY important to test this sprayer with plain water before actual spraying is
attempted. This will enable you to check the sprayer for leaks without the possibility
of losing any expensive chemicals.
Fill the tank about 1/2 full with plain water and drive to the starting place for spray-
ing.
When you are ready to spray, turn the boom valve to the
“
on
”
position (Detail A).
This will start solution spraying from the tips of the boom. The pressure will decrease
slightly when the boom is spraying.
Adjust the pressure by turning the
“
ON/OFF
”
valve lever on the bypass valve
(Detail B). Make sure your pattern is sufficient. You may down
-
pressure the system
by
‘
bypassing
’
solution back into the tank. This is achieved by opening the bypass
valve. Regulating pressure is also done in this manner.
Read the operating instructions and initially begin spraying by closing the bypass
valve and opening the boom line valve (Detail A). This will enable the air in the line to
be eliminated (purged) through all the tips, while building pressure. When everything
tests all right (no leaks and good pressure), add the desired chemicals to the mixture
and water combination and start your spraying operation. Adjust the pressure and
spray as you did in the testing procedure.
Conditions of weather and terrain must be considered when setting the sprayer. Do
not spray on windy days. Protective clothing must be worn in some cases.
Be sure to read the chemical label(s) before application!
Operation
The pumping system draws solution from the tank, through the strainer and to the
pump. Pump forces the solution under pressure to the handgun or boom nozzles.
Fill the tank part way with water and then add the desired amount of chemical to be
sprayed. Finish filling tank to proper level.
Only fill the tank with what you
’
re going to spray in a day, never leave chemicals sit
in tank.
Connect the lead wire to a fully charged 12 volt battery. You may use either a stand
-
alone battery or the battery on your towing
vehicle.
Connect to the positive (red) terminal first, then connect to the negative (black) terminal. Then connect the end of the lead wire to
the end of the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then disconnect the negative
(black) connection and finally the positive (red) connection. The lead wire has an On/Off switch to activate the pump.
“
-
”
is on and
“
O
”
is off. Turn the pump on and by depressing the
“
-
”
side of the rocker switch. The pump is equipped with a pres-
sure switch that is pre
-
set at the factory to shut the pump off when all discharges are closed.
The pump will turn back on when one of the following actions occurs:
Handgun lever is squeezed to spray the handgun.
Boom valve is opened to broadcast spray with the boom.
Bypass valve is opened to re
-
circulate solution back into the tank.
When spraying with either the boom or the handgun, pressure may be reduced by slowly opening the bypass valve until desired
pressure is achieved. Opening the valve decreases pressure, closing the valve increases pressure. When spraying with the boom,
the proper method to set the pressure is to open the boom valve completely and if a lower pressure is desired, then slowly open
the bypass valve until that pressure is obtained.
For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once
you have determined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chem-
ical to be added to the tank. Read the entire label. Use only according to label directions.
Manifold Valves CLOSED
Detail A
Detail B