background image

Page 2 

 

End Nozzle Assembly Procedure 

For Boomless “Wet” Boom 

Your boom will come with the (2) end nozzle assemblies 

NOT affixed to your boom tube. Follow the instructions 

below to attach these properly to the boom tube, as 

shown. 

Assembled 
End Nozzle 

1.  Start by sliding Item 4, 3, 2 onto the boom tube 

(Item 1) as shown, leaving about 1/2” to 3/4”     

between the end of the boom tube and Item 2,   

and make sure the “Long” portion of Item 3 is fac-

ing the nozzle end. 

2.  Slide the (complete) end nozzle assembly onto the 

stainless steel boom tube, with a somewhat 

“twisting” motion, so that the end face of the boom 

tube “butts” up against the surface face inside the 

nozzle body. 

3.  Now push the “compression olive” (Item 3) against 

O-ring (Item 2) and slide (both) into the nozzle 

body opening firmly. 

4.  Firmly tighten flynut (Item 4) onto threads of      

nozzle body. 

5.  Repeat for other side. 

 

NOTE: If water is shooting back on the boom tube, 

item 2 is not in the correct placement. 

Item 2 is shipped inside of 

the end nozzle assembly. 

Remove & place on tube.

 

15° 

End Nozzle Information 

(5275122) 

This nozzle mounting stem 

Has a ratcheting motion. 

** Each “click” of the ratcheting motion is approx. 15° ** 

For proper/optimal spray coverage, 

The nozzle must be at a 15° angle 

 

The 15° angle shown will prevent the outer 

Nozzles from overlapping with the center nozzle. 

“On/Off” Valve Positions 

Valve “Open” 

Valve “Closed” 

Service Position 

On/Off Valve Knob 

Eliminate line pressure, then pull out 

to check diaphragm condition. 

Note: The check valve & diaphragm can fall out during transport, if the 

knob is not turned to the “ON” or “OFF” position. 

Содержание 5301348

Страница 1: ... slightly Attach the boom feeder hose to the boom after routing it through the underside of the carrier frame as needed Secure in place with a hose clamp provided Caution When fully filled with water this sprayer will weigh approx 620 lbs Consult the owner s manual for your vehicle to verify that you are within it s load carrying capacity OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON...

Страница 2: ...ive Item 3 against O ring Item 2 and slide both into the nozzle body opening firmly 4 Firmly tighten flynut Item 4 onto threads of nozzle body 5 Repeat for other side NOTE If water is shooting back on the boom tube item 2 is not in the correct placement Item 2 is shipped inside of the end nozzle assembly Remove place on tube 15 End Nozzle Information 5275122 This nozzle mounting stem Has a ratchet...

Страница 3: ...om nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connect to the negative black terminal Then connect the end of the lead wire to the end of the pump When disconnecting disconnect the end of the pump wire from the lead wire then disconnect the negative bl...

Страница 4: ... valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions on dispos al of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze through the system This will keep i...

Страница 5: ...r defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge...

Страница 6: ...ed to a good 12 volt power source and everything on Slip the two red wires off the terminals and touch them together If the motor runs it means the pressure switch is bad and needs to be replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing th...

Страница 7: ...p and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving the valve connected to the tank Swing swivel the intake assembly towards you Look in the nut you JUST unscrewed There is a screen washer there Remove the screen and clean as necessary Replace when ...

Страница 8: ...loded View Parts List UTL 60 12V BL 5301348 See DETAIL A DETAIL A Ref 1 1 Right Hand RH and Left Hand LH sides of the sprayer are determined as if you are standing behind the sprayer looking at it facing forward ...

Страница 9: ...Page 9 Exploded View Parts List Boomless Wet Boom Assembly 5275260 Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122 ...

Страница 10: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: