Fimco 5301305 Скачать руководство пользователя страница 5

Page 5 

 

Using the Boom Nozzles 

Four things must be considered before spraying with the boom. 

 

How much chemical must be mixed in the tank. 

 

Rate of spray (gallons per acre to be sprayed). 

 

What pressure (p.s.i.) will be used. 

 

Speed traveled (mph) while spraying. 

 

Refer to the chemical label to determine your chemical mixture. 

 

See the tip chart to determine the pressure to be used. The chart will 
also show the speed used when spraying. 

 

Start the pump and open the valve to the boom nozzles. 

 

Check the spray pattern. Usually you can see the coverage better on 
a solid concrete surface, such as a driveway. 

 

Approximate height: 33” 

 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

 

 

 

 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as instructed 

after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s instructions on dispos-

al of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system, including the bypass. Make sure 

to operate the boom and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the tank. Before your next 

usage, rinse the antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

Speed Chart 

  

Time Required in seconds 

Speed in M.P.H. 
(Miles Per Hour) 

100 Ft. 

200 Ft. 

300 Ft. 

1.0 

68 sec. 

136 sec.  

205 sec. 

2.0 

34 

68 

102 

3.0 

23 

45 

68 

4.0 

17 

34 

51 

5.0 

14 

27 

41 

6.0 

11 

23 

34 

7.0 

9.7 

19 

29 

8.0 

8.5 

17 

26 

9.0 

7.6 

15 

23 

10.0 

6.8 

14 

20 

 

The (3) nozzles are fixed at 17-1/2” spacing

 

 

All (3) nozzles spraying at the same time will allow a maximum 
coverage of 30 feet

 

 

The center nozzle will spray an 80” swath

 

 

Each of the (3) nozzles has a shutoff valve, so you can shut off 
each nozzle individually. This may help in achieving the actual 

coverage needed for your application.

 

Rate Chart for Boomless Nozzle (Set of 3) 

Gallons per Acre Based on Water - 17-1/2" Spacing 

Pressure 

P.S.I. 

Capacity 

G.P.M. 

(3 Nozzles)

 

1 MPH  2 MPH  3 MPH  4 MPH  5 MPH  6 MPH  8 MPH 

20 

1.68 

28.0  14.0 

9.4 

7.0 

5.6 

4.7 

3.5 

30 

2.05 

34.4  17.2  11.4 

8.6 

6.9 

5.7 

4.3 

40 

2.40 

'39.6  19.8  13.2 

9.9 

7.9 

6.6 

5.0 

Gallons per 1000 Sq. Ft. Based on Water - 17-1/2" Spacing 

Pressure 

P.S.I. 

Capacity 

G.P.M. 

(3 Nozzles)

 

1 MPH  2 MPH  3 MPH  4 MPH  5 MPH  6 MPH  8 MPH 

20 

1.68 

0.64  0.32  0.21  0.16 

0.13 

0.11  0.08 

30 

2.05 

0.78  0.39  0.26  0.20 

0.16 

0.13  0.10 

40 

2.40 

0.90  0.45  0.30  0.23 

0.18 

0.15  0.12 

Gallons per 100 Sq. Ft. Based on Water - 17-1/2" Spacing 

Pressure 

P.S.I. 

Capacity 

G.P.M. 

(3 Nozzles)

 

1 MPH  2 MPH  3 MPH  4 MPH  5 MPH  6 MPH  8 MPH 

20 

1.68 

0.064  0.032  0.021  0.016  0.013  0.011  0.008 

30 

2.05 

0.078  0.039  0.026  0.020  0.016  0.013  0.010 

40 

2.40 

0.090  0.045  0.030  0.023  0.018  0.015  0.012 

** The rate of spray as shown in the chart will remain the same with 1, 2 or 3 Nozzles ** 

The only difference will be with the width of the spray swath 

Содержание 5301305

Страница 1: ...45 lbs Consult the owner s manual for your vehicle to verify that you are within it s load carrying capacity OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above O...

Страница 2: ...TIGHTEN the whiz lock nuts as this may cause the boom tube to flatten slightly End Nozzle Assembly Procedure For Boomless Wet Boom Your boom will come with the 2 end nozzle assemblies NOT affixed to your boom tube Follow the instructions below to attach these properly to the boom tube as shown Assembled End Nozzle 1 Start by sliding Item 4 3 2 onto the boom tube Item 1 as shown leaving about 1 2 t...

Страница 3: ...e mounting stem Has a ratcheting motion Each click of the ratcheting motion is approx 15 For proper optimal spray coverage The nozzle must be at a 15 angle The 15 angle shown will prevent the outer Nozzles from overlapping with the center nozzle On Off Valve Positions Valve Open Valve Closed Service Position On Off Valve Knob Eliminate line pressure then pull out to check diaphragm condition Note ...

Страница 4: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Страница 5: ...ic and biodegradable and generally safer for the environment than automotive antifreeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system including the bypass Make sure to operate the boom ...

Страница 6: ...r defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge...

Страница 7: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Страница 8: ...Page 8 Exploded View Parts List ATVTS 60 12V BL 5301305 Axle Attachment See Next Page Hub Detail See Next Page Boom Assembly See Next Page Pump Manifold Assemblies See Next Page ...

Страница 9: ...mbly Boom Attachment Axle Attachment Hub Detail 5302350 Manifold Assembly Boomless Wet Boom Assembly Exploded View Parts List 5275260 5116417 Strainer Assembly Center Nozzle Assembly 5275123 End Nozzle Assembly 5275122 Refer to Parts List Previous Page for Part Numbers ...

Страница 10: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Отзывы: