background image

Page 4 

 

Cleaning the Check Valve

If you’re experiencing little to no pressure or the pump is not priming and you’ve checked your 

filter screen and it’s clean, and you’ve gone through the other trouble shooting tips, you may 

need to clean the check valve. 

 

Remove the head of the pump, which is held on by 7 screws. 

 

The first piece inside the head of the pump is called a check valve, it’s the part responsible for building up pressure 
and pumping water/solution through the lines.  

 

Clean the check valve under hot, soapy water (such as a good grade dish soap).  

 

Give it a very light scrubbing with something like an old toothbrush, something with soft bristles. 

 

Then let it soak for about an hour or so in the hot soapy solution and replace in the pump and reassemble the pump. 

 

Most times this will restore most, if not all of the prime of a pump. 

If you’re still having issues with pressure after this step, it would be recommended to replace this part. 

Checking the Pressure Switch

If your motor is not running and you’ve checked the following: for loose wiring connections, fuse, the switch on the 

lead wire was “ON” and made sure you were connected to a fully charged battery and everything is fine, but the  

motor won’t run, then it’s time to check to see if the pressure switch is bad. 

 

Remove the cover off the 1” square box (pressure switch) on the head of the pump, the cover is held on by   
one phillips-head screw. This will  expose the two red wires. 

 

With the pump connected to a good 12 volt power source and everything on. 

 

Slip the two red wires off the terminals and touch them together.  

 

If the motor runs, it means the pressure switch is bad and needs to be replaced.  

If it still doesn’t run, try bypassing the switch in the lead wire or using another lead wire. Even if a tester shows power 

to the pressure switch, it still could be the switch in the wire that is causing the problem. If still not responsive, use a 

voltmeter or electrical tester to make sure you are getting power to the head of the pump, as it could possibly be 

something in one of the wires or even the lead wire assembly may need to be replaced. 

 

Warning:

 It is NOT recommended to run the pump this way, as the pump will continue  

to run and not shut off.  

 

This could result in blown hoses when all discharges are closed. 

Also, this could result in premature failure of the pump completely. 

The suction line of your sprayer should contain a ‘siphon tube’ or intake tube which should be rotated so that it just touches the  

bottom of the tank surface. (see Detail Views). Reach in and rotate it, as needed, if not already in this position. 

 

A shut-off valve is threaded onto the pipe nipple at the intake location on the tank. It is at this location so you can shut off the flow  

of solution to access your system’s screen for cleaning. 

 

Checking/Cleaning the sprayer’s filter/screen: 

 

Start your pump and before it shuts off, reach down and shut the valve to the ‘Closed’ position (lever is perpendicular  

 

 

to the flow of fluid), then shut off your pump. 

 

Unscrew the knurled nut from the shut-off valve, leaving the valve connected to the tank. 

 

Swing (swivel) the intake assembly towards you. Look in the nut you JUST unscrewed. There is a screen/washer there. 

 

Remove the screen and clean as necessary. Replace when done and reassemble the entire assembly. 

 

Make sure the valve is turned to the ‘Open’ position before restarting your pump. 

‘Cut’ View of a ‘Typical’ Tank 

(looking inside) 

Intake/Siphon Tube/Screen Detail of a Typical L&G/ATV Sprayer (not including the ‘EC’Units) 

Содержание 5301063

Страница 1: ...e sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representati...

Страница 2: ... pump on and circulate through system for 15 minutes and then spray out through handgun nozzle Refill sprayer half way with clean water and repeat Follow the chemical manufacturer s disposal instructions of all wash or rinsing water If handgun nozzle needs cleaning remove from the sprayer and soak in warm soapy water Clean with a soft bristled brush or toothpick if necessary Never use a metal obje...

Страница 3: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Страница 4: ...e replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires o...

Страница 5: ...Page 5 Exploded View Parts List LG 28 S 5301063 Intake Assembly 5281145 ...

Страница 6: ...btain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable ...