Step 3 

 
After positioning the tank on the assembled frame, bolt it 

down to the side members, as shown, with the supplied 

(4) 3/8”-16 x 2-1/2” Flanged Hex Bolts, (4) Tank Mount 

Clamps and (4) 3/8”-16 Flanged Hex Nuts. 

 

Assembly Instructions: 

Step 1 

 

Install the lower hitch pins into the bracket lift arm. 

Place these pins through the holes in the pin plates, 

slip the lock washers on and thread the nuts onto the 

pin. Tighten securely. 

T

hi

si

de

 t

ow

ards 

tan

k

 

Step 2 

 
Bolt the frame together as shown. 

Attach one side plate (side plates are the same) to the 

front frame weldment using (3)  3/8"-16 x 1" Flange 

Whiz Lock Screws and (3)  3/8"-16 Hex Whiz Nuts. 

 

Attach back tie plate to side plate using  

(3)  3/8"-16 x 3/4" Flange Whiz  

Lock Screws and (3)  3/8"-16  

Hex Whiz Nuts. 

 

Repeat procedure for the  

other side plate. 

 

 
 
Attach Boom Mounts using (2) 5/16"-18 x 5/8" Flange 

Whiz Lock Screws and (2) 5/16"-18 Hex Whiz Nuts. 

Содержание 3PT-45-12V-4

Страница 1: ...ervice always remember to give the following information Correct Part Description and or part number Model number and Serial Number Part descriptions and numbers can be obtained from the illustrated parts list section s of this manual General Information Thank you for purchasing this product The purpose of this manual is to assist you in operating and maintaining your 3 Point sprayer Retain a copy...

Страница 2: ...ortant for you to test your sprayer with plain water before actual spraying is attempted This will enable you to check the sprayer for leaks without the possibility of losing any expensive chemicals WARNING Read and Understand the Owner s Manual completely before using this sprayer Assemble test and use in accord ance to manual instructions Read and Follow chemical label instructions and wear prot...

Страница 3: ...Owner s Manual Tank Plumbing Pre Assembly Bolt Together 3 PT Sides 3 PT Back Plate 3 PT Welded Front Frame Boom Mounts 4 Nozzle Boom Assembly Contents of Parts Bag 5282432 Contents of Square Boom Parts Bag 5282433 Contents of Bolt Bag 5282434 ...

Страница 4: ...lates slip the lock washers on and thread the nuts onto the pin Tighten securely T h is s id e to w a rd s ta n k Step 2 Bolt the frame together as shown Attach one side plate side plates are the same to the front frame weldment using 3 3 8 16 x 1 Flange Whiz Lock Screws and 3 3 8 16 Hex Whiz Nuts Attach back tie plate to side plate using 3 3 8 16 x 3 4 Flange Whiz Lock Screws and 3 3 8 16 Hex Whi...

Страница 5: ...e boom and using the nozzle clamps attach the nozzle harness to the boom Step 6 After your nozzle harness is attached to the boom attach the boom feeder hose Place 2 hose clamps loosely onto each end of the hose loosely Slip the ends of the hose over the hose barbs on both the manifold and the poly tee fitting on the nozzle har ness Use a twisting motion if necessary to get the hose fully onto eac...

Страница 6: ...h the strainer and to the pump The pump forces the solution under pressure to the handgun or boom nozzles Connect the lead wire to a fully charged 12 volt battery You may use either a stand alone battery or the battery on your towing vehicle Connect to the positive red terminal first then connect to the negative black terminal Then connect the end of the lead wire to the end of the pump When disco...

Страница 7: ...ill sprayer half way with clean water and repeat Follow the chemical manu facturer s disposal instructions of all wash or rinsing water If boom or handgun nozzles need cleaning remove them from the sprayer and soak in warm soapy water Clean with a soft bristled brush or toothpick if necessary Never use a metal object Even the slightest damage can change the flow rate and spray distribution Water r...

Страница 8: ...iring Make sure the ON OFF switch is on Check to see if connected to good Check for Low Voltage Troubleshooting Check for a clogged strainer Check for proper voltage Check for leaks in the discharge line Check for restrictions in the discharge line Check for debris in intake Check for debris in nozzle orifice Check for worn or dirty check valve Low Pressure Low Flow Pump Does Not Prime No Discharg...

Страница 9: ...mmended to replace this part Sprayer and Pump FAQs Why does the pump not run all the time This is an on demand pump and only runs when a discharge is open spray gun bypass boom if applicable or a leak is in the system Why does the pump surge while using the spray gun Low flow high pressure may cause the pump to surge or cycle Typically the spray wand is adjusted at too fine of a mist to overcome a...

Страница 10: ...10 Exploded View Parts List 3PT 45 12V 4 5303244 NOTE Bolt frame together as shown with the proper hardware See Assembly Instructions earlier in this manual Manifold Detail Intake Hose Boom Hose Bypass Hose ...

Страница 11: ...t is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction technology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance includ ing acids as well as exceptional wear life Compact size to prevent tip damage Excellent for systemic products and drift management Opposite side has ...

Страница 12: ...mited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable period of time For more information ...

Отзывы: