• “Fan out” wires as illustrated with 3M-50 below the wall
opening. As in the example: fan out the wires so that the
C wire is above the C terminal, the W above the W. This
allows the 3M-50 to fit snugly to the wall.
Caution
Do not allow wires to touch each other or parts on thermostat.
• Wires will position behind the 3M-50 and up over the
terminal area.
• Do not bunch wires behind the 3M-50. Feed any slack
back into the wall opening.
Connect Your Wires
• Connect labeled wires only to a terminal with the same letter label.
• Insert the wire in the terminal well and tighten the screw securely.
NOTE: If you wish you can mount the 3M-50 to the wall first, and then connect the wires.
• The 3M-50 can be externally powered with a power source rated from 12V to 24V, AC or DC, at
300ma or greater. If used, connect to the C and RH terminals (no polarity).
C B O WW2 YY2RHRCG A
R
H
Y
G
C
W
from HEAT/COOL system