• One of the TIME SLOT icons MORN, DAY, EVEN, NITE 

comes on. This indicates the TIME SLOT active in the energy 

saving program. For program details refer to the energy saving  

program chart.

To Change the Program

 

NOTE: 60 Second Rule-

During programming if a button is not pushed within 60 seconds, the 

unit will go out of the set mode. Everything you have input in this 

programming will automatically be saved.

• Select either HEAT or COOL by setting the MODE switch.  
• Press and hold the

 

 

daily PROGRAM button for 5 seconds.

• Select the day you want to program by pressing 

 to cycle through the days of the week to the 

desired day. 

• Select the Time Slot (period) you want to program 

        (morning, day, evening, night).

• Select the desired start time of that Time Slot by pressing 

 or 

 to set the time.

This is the starting time of the Time Slot.

• Select the desired target temperature for that time slot by pressing the  +/- buttons to select the 

desired temperature for that Time Slot.

• Repeat this setting procedure for all four Time Slots  

        of the day.

• Repeat the setting procedure for all days you want to program.

TARGET

TEMP

HEAT

LINK

RADIO

F

mode

day

time

target temp

time slot

temp

Содержание 3M-22

Страница 1: ...100 Compatible with all popular residential HVAC systems 24VAC single two and stage conventional heating systems gas oil electric heat pumps single or with auxiliary heat electric or fossil zoned forc...

Страница 2: ...rgy Saving Program This thermostat comes preprogrammed with an energy saving program This program is recommended for energy efficiency We strongly recommend that you use this program for one week and...

Страница 3: ...the daily PROGRAM button for 5 seconds Select the day you want to program by pressing to cycle through the days of the week to the desired day Select the Time Slot period you want to program morning d...

Страница 4: ...e week The day of the week display advances initially SU for Sunday Press again to step throught the days of the week until the correct day is displayed SWING HVAC cycling rate This feature allows you...

Страница 5: ...TER ALERT The 3M 22 is programmed to remind you when the HVAC air filter needs changing It is set to remind you every 90 days The Check Filter indicator blinks when your filter limit is reached To cha...

Страница 6: ...F of actual ambient temperature You do have the option however to change the display temperature to match that of a previous thermostat or to match another thermostat already in your home The range of...

Страница 7: ...s also canceled when you set the mode to OFF TEMPORARY override Touch the buttons to select your desired temporary Target Temperature The TEMPORARY icon will display indicating you have modified the p...

Страница 8: ...ts of the HOLIDAY program Press to store your settings NOTE The default HOLIDAY program is set as 2 periods all day same target MORN DAY and EVEN and a different target for NITE Other Functions SAVE E...

Страница 9: ...switch EMER off Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is defective RESET button The RESET button re boots the 3M 22 processor It does...