background image

7

www.filtreco.nl

5. Safety instructions

This system may cause bodily harm or damage to property if 
you do not use it properly and in accordance with all safety 
guidelines,  or  if  you  attempt  to  use  it  for  any  purpose  other 
than that for which it was designed. This system must never be 
operated by children or anyone under the age of 16, or by anyone 
who  has  a  physical,  mental  or  sensory  impairment  or  lack  of 
experience and knowledge, unless they are under supervision 
and have been instructed on the safe usage of the system and 
informed of the dangers associated with it. Children must be 
made aware that this system is not a toy. Cleaning and maintenance 
must be performed by an adult user. This must never be performed 
by a child, even if they are under supervision.

5.1  danger of electrical shock in contact with water

If  your  system  has  not  been  connected  properly  and  in  ac-
cordance with the safety guidelines, and a live electrical current 
comes  into  contact  with  water,  this  can  result  in  electrical 
shock, causing serious injury and even death. Always switch off 
the current on any water-bearing equipment before you come 
into contact with the water.

5.2  Pacemakers

The  cover  has  a  magnetic  switch.  The  magnetic  field  may 
interfere with pacemakers.

5.3  Guidelines for electrical installations

The  electrical  installation  must  be  carried  out  in  accordance 
with  all  national  legislation  and  may  only  be  performed  by  a 
nationally  certified  electrician.  A  person  is  considered  an 
electrician  if  they  have  the  appropriate  training,  knowledge, 
experience and certification, and are capable of assessing and 
conducting the necessary work. The job of an electrical specialist 
also includes recognising any possible hazards and complying 
with all applicable regional and national standards, regulations 
and provisions of law.

• 

For your own safety, always consult a professional electrician 
in case of any problems.

• 

This system can only be connected to a power supply that 
matches its electrical specifications. All specifications for 
this system can be found in this user manual.

• 

The system must be protected by a residual current device 
with a fixed residual current of max. 30 mA.

• 

Use  only  extension  cables  and  power  dividers  that  are 
splash-proof and whose cable diameters are the same as 
the ones supplied with the system.

• 

Do  not  allow  the  plug  connections  to  come  into  contact 
with water or moisture.

• 

Connect the system only to a power outlet that has been 
installed  according  to  industry  standards  and  does  not 
contain a dimmer.

5.4  Safe use

• 

Never use this system in connection with faulty electrical 
cables or a defective housing.

• 

Never pull on the cables to adjust the placement of the 
system.  Ensure  that  the  electrical  cables  are  not  pulled 
tightly.

• 

Lay the cables through a secure duct to avoid damage and 
make sure no one can trip or fall over them.

• 

Only  open  the  housing  of  the  motor  or  other  electrical 
components if this is necessary as instructed by the user 
manual.

• 

Only perform maintenance and other tasks on the system 
as described in this user manual.

• 

In  case  of  any  problems  that  you  are  unable  to  resolve, 
please contact Filtreco.

• 

Only use original spare parts in combination with this system.

• 

Do  not  attempt  to  modify  the  technical  features  or 
specifications of this system in any way.

• 

The connector cables cannot be replaced. In case of a broken 
cable, the entire system or affected part must be replaced 
entirely.

• 

When using in the open air, a roof must be placed above 
the control box and a rain-proof cover must be placed above 
the motor.

• 

Over-voltage  in  the  mains  can  cause  the  system  to 
malfunction. 

• 

Do not inhale the spray mist from the sprayer system. The 
spray mist may contain harmful bacteria.

• 

If the cover is lifted, the flush system stops working. Once 
the  flush  cycle  has  completed,  allow  some  time  before 
opening the cover.

Содержание 100308

Страница 1: ...1 www filtreco nl It is clear www filtreco nl 100308 User manual Drum 100 gravity EN Order number ...

Страница 2: ......

Страница 3: ...en only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Drum 100 gravity By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any work...

Страница 4: ......

Страница 5: ...ations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical specifi...

Страница 6: ...pass the drum and flow past it without being filtered This enables you to still use the biological filtration segment The basin is fitted with a removable waste drain The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away any algae or other coarse particles that cling...

Страница 7: ... For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers that...

Страница 8: ...m diameter Make sure that the duct is positioned at an adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downw...

Страница 9: ...ug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total output of 2500 W from pond pump and spare combine...

Страница 10: ...and or stop the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic ...

Страница 11: ...and check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must increase the inflow capacity to the filter or reduce the pump capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible Che...

Страница 12: ...nge Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an addition...

Страница 13: ...eal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot withstand freezing tempera...

Страница 14: ...14 Drum 100 gravity 16 Technical diagram ...

Страница 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P ...

Страница 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...

Отзывы: