Filtech DP 200 Скачать руководство пользователя страница 35

Date/Signature

Date/Signature

Intervento successivo/

 Next

intervention
Intervento programmato/

Scheduled intervention

Содержание DP 200

Страница 1: ...Reverse osmosis device Use and maintenance manual EN DP 200 DP 200 T DP 200 SLIM DP 200 SLIM LT DP 400 DP 400 T DP 500 DP 500 T...

Страница 2: ......

Страница 3: ...OF USE AND PERIOD OF USE 9 6 INSTALLATION 11 7 SPARE PARTS AND PRE FILTRATION 13 8 USE 13 9 MAINTENANCE 15 10 ELECTRONIC MANAGEMENT 18 11 FAULT MANAGEMENT 23 12 GENERAL DESIGN 25 13 WARRANTY RULES 30...

Страница 4: ...y with these instructions will void the warranty The manufacturer cannot be held in any way liable for any damage to people or property caused by a failure to comply with this attached manual which is...

Страница 5: ...the water pass in all its genuine purity REVERSE OSMOSIS is therefore the safest and most widespread purification system around the world the advantages other than the basic reliability of the system...

Страница 6: ...ON PPM 0 1 MAX PERMITTED MANGANESE PPM 0 1 MAX SALINITY S Cm 1500 MIN MAX AMBIENT TEMPERATURE C 5 40 MAX RELATIVE HUMIDITY 95 NOMINAL PERFORMANCE MODEL PRODUCTION 15 C PRODUCTION 25 C RECOVERY RATE RE...

Страница 7: ...system from the electricity mains by taking out the plug from the power outlet in the event of a fault or poor operation switch off the reverse osmosis purifying system and do not tamper with it Conta...

Страница 8: ...urement between the control unit and the back side NO LOAD WEIGHT Kg DP 200 22 44 45 22 4 DP 200 T 43 5 44 45 32 9 DO 400 22 44 55 30 1 DP 400 T 43 5 44 55 42 4 DP 500 22 44 66 34 6 DP 500 T 43 5 44 6...

Страница 9: ...nalling Replacement and sanitisation Membrane life Most critical condition 2 years or exhaustion Installation booklet present Replacement and sanitisation Machine off without electrical supply Over 10...

Страница 10: ...36 C CFU mil 1 1 Vital microorganisms at 22 C CFU 1mil 1 21 Escherichia coli CFU 100mil 0 0 Coliform bacteria CFU 100mil 0 0 Intestinal enterococci CFU 100mil 0 0 pH Unit of pH 7 44 7 25 Conductivity...

Страница 11: ...e quality of the input water Installations repairs interventions or changes must be carried out by authorised staff The SLIM models require non optional FC500 filtration Before proceeding with the ins...

Страница 12: ...tem In the pressure testing pha se it is adjusted to 8 bar The pressure can vary based on the actual conditions at the installation site or based on system wear After installation and during the maint...

Страница 13: ...ling pre filtration or use of unapproved components will cancel the warranty Approved pre filtration FC500 FC500 Puro For maintenance use only spare parts supplied or approved by the manufacturer 8 US...

Страница 14: ...which if the system is locked re routes the entire input water directly to the output by opening the solenoid valve Doing so even if not treated water can be delivered while waiting for technical supp...

Страница 15: ...ding it horizontally 3 Prepare the new filter removing the seal 4 Position the new filter inserting it in the head guides 5 Position the lock box pushing it up to end of stroke ensure the buttons have...

Страница 16: ...g slider 3 Osmotic membrane 3012 4 Sealing plug 5 Vessel key 6 Closing plug For filter replacement proceed as follows Turn off the electrical power supply to the system for the SLIM versions close the...

Страница 17: ...e vessel unit position its dovetails in the casing slits move delicately downwards ensuring the L shaped connectors and permeate connectors are correctly inserted Having done this position the locking...

Страница 18: ...tion via dip switch LEGEND Num Position connection Description 1 Minimum pressure switch Brown cables with faston 6 3 2 Solenoid valve Brown blue cables with faston 6 3m 3 Pump motor connection Brown...

Страница 19: ...f the equipment In particular if pressed during the machine on status the following will be displayed in sequence filter flow rate LCD board firmware version power board firmware version CONFIGURATION...

Страница 20: ...w reader with alarms Flushing after each delivery Anti residue every 6 hours Filter management based on time and litres delivered Detection of leaks and water flow obstructions on the machine Configur...

Страница 21: ...s the filter The capacity can be set based on the quantity of water processed and the time past When the filter runs out the icon 9 will be flashing the board can lock or not based on the configuratio...

Страница 22: ...Icons 13 14 21 flashing Low pump pressure Icons 13 14 21 flashing High pump pressure Icons 13 14 21 flashing Permeate quality alarm Lock Threshold Icons 13 14 15 flashing Permeate flow rate alarm Loc...

Страница 23: ...if the membranes are exhausted low permeate flow rate Check if the pump bypass is correctly adjusted if an intervention is necessary follow the instructions in the manual carefully Permeate quality a...

Страница 24: ...ine can work with pressure in the upper permeate duct the entire system should be appropriately shaped The machine resets to the non delivery mode Check the following points in the given order 1 The p...

Страница 25: ...25 English 12 GENERAL DESIGN DP 200 DP 400 DP 500...

Страница 26: ...26 DP 200 T DP 400 T DP 500 T...

Страница 27: ...27 English DP 200 SLIM DP 200 SLIM LT...

Страница 28: ...8 Control unit with wiring 9 Display varies based on model 10 Casing display 11 Display protection 12 Filtering cartridge 13 Conductivity sensor 14 Filter box 15 Pump pressure transducer 16 Permeate p...

Страница 29: ...32 Osmotic membrane 3012 40 RACCO030 tank fitting 41 JG fitting G3 8 tube 12 42 Tank version tubes kit varies based on model 43 JG T 12 44 DP tank 101 JG reduced elbow 10 8 102 JG reduced elbow 3 8 5...

Страница 30: ...be carried out by qualified staff If the machine has to be repaired in a qualified laboratory expenses and risks of transport to and from such laboratories shall be borne by the purchaser 6 Lack of ma...

Страница 31: ...in the EU Directives in force DIRECTIVE 2014 35 EU LVD DIRECTIVE 2014 30 EU EMC DIRECTIVE 2011 65 EU ROHS IEC EN62233 DIRECTIVE 2014 68 EU PED MINISTERIAL DECREE 174 OF 6 APRIL 2004 MINISTERIAL DECRE...

Страница 32: ...china Machine data modello model matricola n serial no data di installazione installation date Owner Resident in IMPIANTO AD OSMOSI INVERSA REVERSE OSMOSIS SYSTEM Timbro e firma rivenditore Dealer s s...

Страница 33: ...Date Signature Date Signature Intervento successivo Next intervention Intervento programmato Scheduled intervention PRIMA SANIFICAZIONE FIRST SANITISATION TABELLA MANUTENZIONI MAINTENANCE TABLE...

Страница 34: ...Date Signature Date Signature Intervento successivo Next intervention Intervento programmato Scheduled intervention...

Страница 35: ...Date Signature Date Signature Intervento successivo Next intervention Intervento programmato Scheduled intervention...

Страница 36: ...Code DP FT 2020 02 03 EN...