FILL-RITE FR100 Series Скачать руководство пользователя страница 1

FR100 Series Rotary Hand Pump

FR110, FR112, FR112C, FR113 

Installation and Operation Manual

Thank You!

On behalf of every employee at Tuthill, thank you for 

choosing Fill-Rite for your fluid transfer needs! Your Fill-

Rite pump comes with over 50 years of pump design 

and construction experience. If this is your first Fill-Rite 

pump, welcome to the family; if it isn’t, welcome back! 

Our commitment to excellence provides the quality, 

performance, and durability you expect and deserve.

We look forward to serving your fluid transfer needs! 

        

WARNING! 

The FR100 Series hand pump shall not 

be used to pump fuel into any type of aircraft!

Compatible Fluids 

(Okay to pump)

Gasoline, Diesel, Heptane, 

Kerosene, Stoddard Solvents, 

Light Oils, Mineral Spirits

Non-Compatible 

Fluids 

(

DO NOT

 

pump

)

Water, Sulfuric Acid, Naptha, 

Methanol, Methyl Ethyl Ketone 

(MEK), Acetone, Ammonia, 

Benzene, Bleach, Chlorine

Fluid Compatibility

        

WARNING! 

The FR100 Series hand pump is not 

suitable to pump fluids for human consumption, or fluids 

containing water.

Safety Instructions

To ensure safe and efficient operation, it is essential to 

read and follow each of these warnings and precautions:

1.  Improper use or installation of this product can cause 

serious bodily injury or death.

2. 

Do NOT smoke near pump or use pump near an open 

flame when pumping flammable fluids. Fire could 

result.

3.  A Fill-Rite filter should be used on pump outlet to 

ensure that no foreign material is transferred to fuel 

tank.

4.  Use gasoline and oil resistant thread sealant or 

sealant tape on all threaded joints to protect against 

leakage.

5.  Storage tank or barrel should be anchored to prevent 

tipping in both the full and empty conditions.

6.  To minimize static electricity build-up, keep nozzle in 

contact with container being filled.

Safety Certification

Pump Installation

        

IMPORTANT! 

All pipe threads must have a sealant 

to protect against leaks. Use sealant tape provided 

with the pump, or use a gasoline and oil resistant pipe 

sealant.

1.  Screw suction pipe into pump inlet flange and tighten.

2.  Extend suction pipe into tank or barrel opening to with

-

in 3” of bottom of tank or barrel. Do not rest suction 

pipe on bottom.

3.  Screw inlet flange of pump completely and securely 

into undamaged tank or barrel bung.

Pumps with Hoses and Nozzles

4.   Screw one end of hose into pump discharge opening 

       and the nozzle to other end of hose.

Pumps with Discharge Spouts

4.    Screw discharge spout assembly into top of pump.

Pumps with Meter, Hose, and Nozzle

4.    Screw street elbow into top of pump, nipple into street 

       elbow, meter onto nipple. Note: Position the meter to 

       the right of the handle facing operator for ease of 

       operator viewing. Screw one end of hose into meter 

       outlet and the nozzle to the other end of hose.

Installation of Counter

1.  Remove crank from shaft.

2.  Remove two screws directly above horizontal 

centerline of pump.

 

Push drive gear onto shaft with flat in gear hole 

located on longer flat of shaft.

3.  Position counter on pump and attach with two screws 

and two washers.

4.  Reattach crank.

T

roubleshooting

If Pump Fails to Prime: 

Check suction line for leaks or 

obstructions. Check vanes and slots for nicks, burrs or 

wear. Check rotor for excessive wear or damage.

 

Low Pumping Capacity: 

Remove and clean screen. 

Check for leaks in suction line. Check rotor and vanes for 

excessive wear and damage. Check for dirty filter on outlet 

side.

 

Pump Fluid Leakage:

 Clean O-ring seal and seat area. 

Replace seal. Replace vacuum breaker. Tighten covers 

and joints. Check for dirty filter on outlet side.

Содержание FR100 Series

Страница 1: ...pty conditions 6 To minimize static electricity build up keep nozzle in contact with container being filled Safety Certification Pump Installation IMPORTANT All pipe threads must have a sealant to pro...

Страница 2: ...iter Meter Kit 100ACC111 Gallon Counter Kit 100ACC111L Liter Counter Kit F1810PM0 Particulate Filter Kit F1810HM0 Hydrosorb Filter Kit 1200KTG9075 Filter Head Repair and Accessory Kits 2 100G9132 REV...

Страница 3: ...ci n de la bomba IMPORTANTE Todas las roscas de tuber a deben tener un sellador para proteger contra las fugas Use cinta selladora que se proporciona con la bomba o bien use un sellador de tuber as re...

Страница 4: ...nes 100ACC111L Juego de contador de litros F1810PM0 Juego de filtro de particulado F1810HM0 Juego de filtro Hydrosorb 1200KTG9075 Cabezal de filtro Juegos de reparaci n y accesorios 2 100G9132 MOD 2 2...

Страница 5: ...issage Certification de s curit Installation de la pompe IMPORTANT Tous les filetages de tuyau doivent comporter un produit d tanch it pour viter les fuites Utiliser le ruban d tanch it fourni avec la...

Страница 6: ...100ACC111 N cessaire compteur gallons 100ACC111L N cessaire compteur litres F1810PM0 N cessaire filtre particules F1810HM0 N cessaire filtre Hydrosorb 1200KTG9075 T te de filtre Trousses de r paratio...

Страница 7: ...pfventil in Kontakt mit dem Beh lter sein der gef llt wird Sicherheitszulassung Montage der Pumpe WICHTIG Alle Rohrgewinde m ssen zum Schutz vor Lecks mit Dichtmittel versehen werden Das mit der Pumpe...

Страница 8: ...Gallonen 807CLMK Dosierersatz Liter 100ACC111 Z hlersatz US Gallonen 100ACC111L Z hlersatz Liter F1810PM0 Partikelfiltersatz F1810HM0 Hydrosorb Filtersatz 1200KTG9075 Filterkopf Ersatzteil und Zubeh r...