ASSEMBLY/DISASSEMBLY

4

MAINTENANCE

Disconnect power to dispenser before removing cover.  Drain

liquid from system before loosening any fittings to prevent

excessive spillage.

Dispenser Cabinet

 

(see assembly drawing)

Disassembly

1. Remove front plate (item 1) by removing two screws (item

16).

2. Remove faceplate (item 51) by removing two screws (item

53).

3. Pull off reset knob (item 50).

4. Remove six screws (item 10) from cabinet top (item 11).

5. Turn switch handle (item 18) to vertical position.

6. Remove top and set aside to expose junction box and meter.

Assembly

1. Replace cabinet top, making sure it slips over the meter and

the outside edges of the cabinet base (item 2).

2. Replace screws in cabinet top.  Install the two screws in back

of cabinet before replacing side screws.  Position top

squarely before tightening screws.

3. Attach reset knob.

4. Replace faceplate and front plate.  Align each before tight-

ening.

Meter

 

(see 900 meter drawing)

Meter can be completely disassembled without disturbing

piping, or meter can be partially disassembled as required.

Meter Counter Assembly

 

(item 10)

1. To expose counter assembly, remove front plate and face-

plate per cabinet disassembly.

2. Reassemble by reversing procedure.

NOTE: 

 

Due to complicated assembly methods, individual

counter assembly  parts are not available.  The complete

assembly must be replaced if problems occur.

Meter Chamber Assembly

 

(item 3)

1. To expose meter chamber assembly, gear train and seal,

remove four bolts (item 34) from back of meter.

2. Meter chamber assembly can be removed by removing four

screws (item 5).

3. Reassemble by reversing procedure.

Meter chamber assembly consists of upper and lower

chambers and nutating disc.  If replacement of any

components of the meter chamber assembly is required, the

complete assembly must be replaced due to the precise

method of its construction.  This assures a proper fit and a

correctly operating chamber.

Meter Gear Train and Seal

1. To access gear train or seal, remove two screws (item 5) and

gear frame (item 6).

2. Remove cluster gear (item 20), shaft (item 19) and washer

(item 21).

 3. Remove drive gear (item 26) and washers (item 25) by

rotating and pulling drive gear.

4. Remove O-ring seal (item 27).  When reassembling seal,

lubricate O-ring with oil or petroleum jelly and replace in

cover.

5. To reassemble, place washer on drive gear shaft.  Rotate and

push shaft through O-ring and cover carefully to prevent

damage to O-ring.  Shaft must then be guided into pinion

bevel (item 29) if counter has not been removed.

6. Replace remaining parts by reversing procedure.

Meter should operate maintenance free.  However, certain

liquids can dry out while in meter housing, causing meter to

stop.  If this happens, meter should be thoroughly cleaned (see

cleaning instructions below).

Cleaning Instructions:

1. Meter can be removed from dispenser by removing eight

screws (items 22 and 27 on dispenser drawing).

2. Run a flushing fluid through meter.  For a more thorough

cleaning, disassemble meter according to the

“ASSEMBLY/DISASSEMBLY” section, “Meter Chamber

Assembly” subsection of this manual.  Rinse all  meter

components.  Recalibrate meter following calibration

instructions.

Содержание 305RU

Страница 1: ...305 REMOTE DISPENSER Owner s Operation Safety Manual OUTSTANDING FEATURES From 6 to 40 GPM 23 to151 LPM Meter accuracy of 2 Model 305RU ...

Страница 2: ...ositive displacement nutating disc type Can be calibrated for 2 accuracy within a fluid range of 6 to 40 GPM 23 to 151 LPM Register Three resettable unit wheels with large 11 16 figures and tenths wheel Totalizer reads to 999 999 9 gallons Cabinet measures 13 W x 11 1 2 D x 10 1 2 H Liter measure Four resettable unit wheels Totalizer reads to 99 999 999 liters Front or rear discharge Red or white ...

Страница 3: ...r source to remaining opening in base 4 Withpowerturnedoff connectpumpwiresandpowerwires to line switch leads per wiring diagram Connect ground wires to ground screws in junction boxes and to ground source 1 Afterhose nozzle filter etc havebeeninstalled holdnozzle open into tank opening or container and turn on switch handle Allowpumptoprimeandevacuateairfromsystem 2 Reset meter to zero 3 To check...

Страница 4: ...k of meter 2 Meterchamberassemblycanberemovedbyremovingfour screws item 5 3 Reassemble by reversing procedure Meter chamber assembly consists of upper and lower chambers and nutating disc If replacement of any components of the meter chamber assembly is required the complete assembly must be replaced due to the precise method of its construction This assures a proper fit and a correctly operating ...

Страница 5: ... 5RG 1XW RWWHU 3LQ 6 6ZLWFK HYHU URRYH 3LQ 6ZLWFK DQGOH UDFNHW 2XWOHW LWWLQJ 6 6ZLWFK 5RG LWFK 3LQ OLS 6ZLWFK HYHU QFOXFHG Z WHP RFNQXW QFOXGHG Z WHP 6 6WDQGDUG 1R OH RRW 5HG 6WDQGDUG 1R OH RRW KLWH 2SW 1LSSOH RQGXLW OERZ RQGXLW 1LSSOH 8 1XW 0 RQGXLW OERZ DVKHU 2 6 H 3OXJ 6ZLWFK RXVLQJ UDFNHW 6ZLWFK RXVLQJ VVHPEO 0HWHU 8 6 DOORQ 0HWHU LWHU 2SW DWKH XW DVNHW QOHW DVWLQJ 5HVHW RXSOLQJ 6HW 6FUHZ 5HVH...

Страница 6: ...6 WHEN ORDERING REPAIR PARTS BE SURE TO GIVE RE PLACEMENT PART NUMBER DATE OF MANUFACTURE AND DISPENSER SERIES NUMBER THIS WILL ENSURE THAT THE CORRECT REPLACEMENT PART IS SUPPLIED ...

Страница 7: ...WIRING DIAGRAM TANK MOUNTING LAYOUT DISPENSER BASE LAYOUT 7 ...

Страница 8: ...19 800 16 F3820 Shaft Cluster Gear 1 20 800 159 F3841 Cluster Gear U S Gallon 1 800 161 F3843 Cluster Gear Liter Opt 21 800 18 F3830 Washer 1 22 900 11 F8063 Driver Pinion Shaft Included w item 7 1 23 900 13 F8065 Retaining Ring 1 24 900 12 F8064 Driver Pinion 1 25 800 55 F3980 Washer 2 900 SERIES METER PARTS LIST 900 SERIES METER PARTS LIST ITM PART PROC NO NO NO DESCRIPTION QTY 26 800 160A F3845...

Страница 9: ...ean O ring seal and seat area leakage Bad seal Replace seal TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION 9 ABOVEGROUND TANK INSTALLATION NOTE USE APPROVED PIPE COMPOUND ON ALL PIPE THREADS ELECTRICAL NOTE ELECTRICAL WIRING SHOULD BE DONE IN ACCORDANCE WITH APPROVED LOCAL ELECTRICAL CODES AND BY A LICENSED ELECTRICIAN THE PUMP SHOULD BE PROPERLY GROUNDED AND RIGID CONDUIT SHOULD BE USED WH...

Страница 10: ... Corporation Manufacturer warrants to each buyer of its products the Buyer for a period of 12 months from date of installation but in no event more than 18 months from date of manufacture that goods of its manufacture Goods will be free from defects of material and workmanship Specific to Series 10 12 20 and 22 Warranty is under stood not to exceed 6 months and is specific to all related items Man...