FLSC
GB
Betriebsanleitung
•
73734 Esslingen - Fiessler Elektronik - Kastellstr.9
•
Doku Nr. 625 R.H.
183
Properties
Data
min.
type
max.
Switching voltage
HIGH active (Ueff)
13.4 V
at Uv = 16.8 V
Voltage LOW
0 V
2.5 V
Switching current
(referred to EXT_GND)
4 mA
250 mA
Time behaviour of output
without restart inhibit
Depends on scan rate
Activation on protective field (SF) clear
190 ms
Time behaviour of output
with restart inhibit
Depends on scan rate
Activation on protective field (SF) clear
580 ms
Time behaviour of output
after n seconds
Depends on scan rate
Activation on protective field (SF) clear
3 s
Short-circuit protected
by monitoring of outputs
Fault: Leak current
2.1 mA
Fault: Interruption of GND cable.
The downstream control element
must recognise this status as Low.
Pure load capacity
100 nF
Switching
frequency
3
Hz
Pure load inductivity
2H
At low switching frequencies the max.
permissible load inductivity is higher.