I
NSTALLATION
24
Checking the customer site
Before you install the E-8100, check site conditions and inform the customer of any
installation requirements.
Copier readiness
Is the copier configured for use with the E-8100? See
“Preparing the copier to connect to the
Is space available near the copier for the E-8100?
Make sure that adequate space is available for the E-8100. Allow enough space at the back
panel for the cables to route easily and at the side panel so that the E-8100 does not interfere
with use of or service to the copier (such as clearing a paper jam). You may need to move the
copier away from the wall so that the interface connectors are accessible.
Does the copier require service or adjustments?
Print the copier Test Page before you install the E-8100.
If the image indicates that the copier needs adjustment, inform the customer. After getting
approval, complete the necessary copier service.
Power
Is there a dedicated, grounded electrical outlet for the E-8100 near the copier?
Locate the grounded electrical outlet that will supply power to the E-8100. Do not run the
E-8100 and the copier on the same circuit. Use a surge suppressor for the E-8100 if the
customer has provided one.
•
Do not
use a 3-prong adapter in a 2-hole ungrounded outlet.
•
Do not
use an extension cord.
•
Do not
plug the E-8100 into a circuit with heating or refrigeration equipment (including
water coolers).
•
Do not
plug the E-8100 into a switchable wall outlet. This can result in the E-8100 being
turned off accidentally.
•
Do not
pull on the cable when unplugging the E-8100. Pull the plug instead.
Back panel
Side panel
20cm+ (8 in.)
E-8100
20cm+ (8 in.)