FieldServer FS-X25 Series Скачать руководство пользователя страница 12

FieldServer FS-X25 Start-Up Guide  

 

 

 

 

 

 

Page 12 of 12 

FieldServer Technologies

 1991 Tarob Court Milpitas, California 95035 USA   

Web

: www.fieldserver.com 

Tel

: (408) 262 2299   

Fax

: (408) 262 2269   

Toll Free

: (888) 509 1970   

email

: [email protected] 

Appendix B.

 

Limited Warranty 

FieldServer Technologies warrants its products to be free from defects in workmanship or material under normal 
use  and  service  for  two  years  after  date  of  shipment.    FieldServer  Technologies  will  repair  or  replace  without 
charge any equipment found to be defective during the warranty period.  Final determination of the nature and 
responsibility for defective or damaged equipment will be made by FieldServer Technologies personnel. 

All warranties hereunder are contingent upon proper use in the application for which the product was intended 
and  do  not  cover  products  which  have  been  modified  or  repaired  without  FieldServer  Technologies  approval  or 
which  have  been  subjected  to  accident,  improper  maintenance,  installation  or  application,  or  on  which  original  
identification marks have been removed or altered.  This Limited Warranty also will not apply to interconnecting 
cables or wires, consumables or to any damage resulting from battery leakage. 

In all cases FieldServer Technology’s responsibility and liability under this warranty shall be limited to the cost of 
the  equipment.    The  purchaser  must  obtain  shipping  instructions  for  the  prepaid  return  of  any  item  under  this 
warranty provision and compliance with such instruction shall be a condition of this warranty. 

Except for the express warranty stated above, FieldServer Technologies disclaims all warranties with regard to the 
products sold hereunder including all implied warranties of merchantability and fitness and the express warranties 
stated  herein  are  in  lieu  of  all  obligations  or  liabilities  on  the  part  of  FieldServer  Technologies  for  damages 
including, but not limited to, consequential damages arising out of/or in connection with the use or performance 
of the product. 

Содержание FS-X25 Series

Страница 1: ...Sierra Monitor Company APPLICABILITY EFFECTIVITY Effective for all systems manufactured after March 2009 FieldServer X 25 Start Up Guide Kernel Version 5 12 Document Revision 2 ...

Страница 2: ...3 1 2 DB 9 Pinouts for RS 485 Connection 7 3 2 Ethernet Connection 7 4 Operation 8 4 1 Record Identification Data 8 4 2 Power up the device 8 4 3 Install and Run the Utility Software 8 4 4 Connect the PC to the FieldServer over the Ethernet port 8 4 5 Identification of the FieldServer on the Network 8 4 6 Connection to the FieldServer Using RUI Ruinet 9 4 7 Upload the Default Configuration 9 4 8 C...

Страница 3: ... Supply 1 2 Mounting The FS X25 Series FieldServer is supplied with an accessory bag which allows selection of adhesive feet for standing on a shelf or mounting plates for wall or panel mount A DIN Rail Mounting Kit P N FS 8915 28 may be ordered separately 1 3 Wiring 5 30VDC must be connected to the terminal block 1 3 1 Compliance with UL Regulations For UL compliance the following instructions mu...

Страница 4: ... power supply Physical Dimensions LxWxD 4 55 x 4 50 x 1 35 in 11 56 x 11 68 x 3 43 cm Weight 0 4 lb 0 18 Kg Field Connections Ethernet Port 10BaseT 100BaseTX RJ45 auto sensing Serial Port RS 232 RS 422 RS 485 switchable Up to 115K baud DB9 connector Drivers Drivers available for a wide range of Ethernet and serial protocols check driver information sheet Environment Operating Temperature 40 85 C 4...

Страница 5: ...interface auto sensing Easy configuration via text editor or spreadsheet and the available utilities OPC server available Configuration utility Diagnostic utility System integration services available 2 2 LED Indicators Ethernet connection Tx Rx communication activity Green LED 10 100 indicator LED on 100 megabit connection LED off 10 megabit connection Orange LED Link activity indicator LED on Li...

Страница 6: ...gured as either P1 for RS 232 connection or R1 for RS 485 connection Likewise the Serial 2 port can be configured as P2 or R2 Note that if a P1 and a R1 connection is declared the one declared second will cause a configuration error on the error screen Figure 1 Serial Connection Ports 3 1 1 DB 9 Pinouts for RS 232 Connection Used to connect to DTE type devices Typical null modem connection Used wh...

Страница 7: ... be connected as per diagram when unused to prevent loss of performance on the FieldServer For users who do not wish to construct their own connector we recommend using a DB 9 to screw block connector which can be purchased from L Com Inc Item DGB9FT Ph 1 800 341 5266 http www l com com item aspx id 8141 3 2 Ethernet Connection The FS X25 Ethernet port automatically senses an uplink connection and...

Страница 8: ... PC laptop Open Index html to get the menu of options run the Install option and follow the installation instructions Once installed the FieldServer Utilities can be located in the Windows Start menu and as a desktop icon 4 4 Connect the PC to the FieldServer over the Ethernet port Use the supplied Cat5 UTP Ethernet cable to connect between the N1 port of the FieldServer and the hub Refer to Secti...

Страница 9: ...figuration is not purchased a template config csv is shipped on the FieldServer Refer to the Configuration Manual and the Driver Manual s provided with the FieldServer for further information on configuration files In the main menu of the Remote User Interface screen type U to upload the configuration Then type U again The Remote User Interface Utility will fetch the default configuration and put ...

Страница 10: ... will indicate when download is complete DO NOT reset the FieldServer before this message displays as this could corrupt the FieldServer Once download is complete hit Esc to get back to the main menu and use the option or simply cycle power to the FieldServer to put the new file into operation Note that it is possible to do multiple downloads to the FieldServer before resetting it Firmware created...

Страница 11: ...all is disabled Ensure that all other Ethernet cards active on the PC especially wireless adapters are disabled Refer to the FieldServer Troubleshooting Guide which can be found in the FieldServer Utilities directory under Documentation Appendix A 2 Technical support Before contacting Technical support to report an issue go to Start Programs FieldServer utilities Tools and run the FST_Diag program...

Страница 12: ... approval or which have been subjected to accident improper maintenance installation or application or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery leakage In all cases FieldServer Technology s responsibility and liability under this warranty shall...

Отзывы: