Safety Information

Only qualified personnel trained in service 

and installation of electric heaters, boilers, and 

furnaces shall use this combustion analyzer 

This device measures and analyzes key 

parameters of combustion equipment including 

oxygen, carbon monoxide, temperature, carbon 

dioxide, efficiency, and draft pressure  

Read and understand this operator’s manual 

in its entirety before using to prevent injury 

or damage to you or the equipment  As with 

any job, appropriate use of personal protective 

equipment (PPE) is required 

 

!

 WARNING

• 

Do not use the analyzer as a safety device. 

• 

Always be aware of and test for ambient CO levels.

• 

Do not use unless in a well-ventilated location.

• 

Do not use in areas classified as hazardous locations; not 

intrinsically safe.

• 

Do not use unless a visual inspection ensures it’s safe to do so. 

• 

Ensure any connections to fuel sources are leak-free.

• 

Do not touch or store probe until it cools to ambient 

temperature. 

• 

Condensate may be acidic.

• 

Combustion gases may be toxic even in low concentrations.

• 

Seal any equipment holes used during testing in order to 

prevent dangerous flue gas entering the space. 

 

!

 CAUTION

• 

Do not use or store near solvents. 

• 

Do not clean with solvents. 

• 

Do not use on a continuous basis.

• 

Refer to 3rd party smoke test documentation to verify if smoke 

in equipment is at a safe level (1 or less). Not verifying this prior 

to conducting other tests, such as combustion, can result in 

damage of the analyzer and produce incorrect measurements.

• 

This device should only be opened and/or serviced by 

authorized personnel. Gas sensors may be replaced by user. 

• 

Do not disconnect combustion probe cable when powered on. 

• 

Use only within operating environment specification.

• 

Do not use in the rain or wet environments. 

Содержание CAT85

Страница 1: ...Fieldpiece Combustion Analyzer HC OPERATOR S MANUAL Model CAT85 ...

Страница 2: ...le Pump Battery Charging Powering ON Powering OFF Storage Job Menu 14 Combustion Ambient CO Drafts Primary Air Smoke Fuel Pressures Manometer 20 Customer Note Report Save and Exit Job Archive Settings 24 Maintenance 26 General Dust Filter Replacement Sensor Replacement Calibration Specifications 30 Sensors Test Parameters Limited Warranty 34 Sensor Warranty Obtaining Service ...

Страница 3: ...nless a visual inspection ensures it s safe to do so Ensure any connections to fuel sources are leak free Do not touch or store probe until it cools to ambient temperature Condensate may be acidic Combustion gases may be toxic even in low concentrations Seal any equipment holes used during testing in order to prevent dangerous flue gas entering the space CAUTION Do not use or store near solvents D...

Страница 4: ...onvenience The combustion probe uses a patent pending HydroCycle pump to return condensate back into the flue no more water trap hassles Features 4 Year Gas Sensor Warranty Large Intuitive Touchscreen Powerful Trending SensorVault Technology HydroCycle Pump Real time Live Draft Pressure Dual Manometer Ports Rechargeable Battery In use USB C Charging Field Replaceable Smart Sensors Job Link System ...

Страница 5: ... Sensor Cover 2 2 5mm Hex Sockets Probe Cable Connector Pull Push at Arrows 4 Magnetic Mounts Click Power Button SensorVault Technology Threaded Probe Cone Lock HydroCycle Pump CondenserVentilation Filter Cap 1 4 turn HydroCycle Pump Condensate Outlet Sensing Point Flue Gas Inlet Temperature Sensor Probe Pressure Filter O ring ...

Страница 6: ...r design and therefore their ideal sampling points However there are commonalities that make for useful guidelines when analyzing performance Heed equipment manufacturer instructions above anything mentioned in this manual Before inserting the probe in the flue it s good practice to test for excessive soot which may lead to carbon buildup within the analyzer or overexpose sensors Use the probe con...

Страница 7: ... accurate sensor zeroing Thisstepshouldbeexecutedoutsideofthetestroomandaway fromanyvehicleexhaustwheretracesofCOcouldbelingering DonotrelyontheanalyzeralonetocheckforunsafeCOlevels 3 Fully press the power button down until you feel and hear the click of the SensorVault technology UNSEAL the sensors Pressdeeperifitdisplays SEALED 4 Wait for start countdown to complete 5 Start testing See JobMenu s...

Страница 8: ...nts Forbestresults testforatleast5minutesnearthecenterofthe flue whereyoufindthehighestlevelofCO 7 SAVE ALL measurements displayed 8 Remove the probe and cone from the flue when finished Becarefulnottoletthemetaltouchanythinguntilitcools Reference Ranges When selecting equipment the reference range icon shows when available Temperature O2 CO and CO air free all have reference ranges These ranges s...

Страница 9: ...ive draft pressure with the COMBUSTION test but a saved FLUE DRAFT measurement overrides this value Draft pressure measurement is important for safety and performance The probe pressure sensor is used for all three drafts Read SafetyInformation section 1 Ensure startup is complete See PoweringOn section 2 Select DRAFTS from the JOB MENU 3 Mount the CAT85 onto a secure cool magnetic surface near th...

Страница 10: ...rom the JOB MENU 3 Use your smoke tester to find the smoke level 4 Select the corresponding level on screen 5 SAVE the smoke level DELETE deletestheentry Fuel Pressures CAT85 has P1 and P2 pressure ports for connecting hoses not included to gaseous fuel sources regulators Do not test liquid fuels This is very similar to the Manometer test but uses fuel centric labels that aid in reporting Read Saf...

Страница 11: ...sureprobesforbettercontrol 7 View live measurements SAVE any measurement displayed Formeasurementslessthan2inWC savereadingwithin1minute afterzeroingforbestaccuracy DELETE temporarilydeletesasinglevaluesoyoucanretest DELETETEST deletesthetest Customer Each job has a customer entry JOB ARCHIVE uses this entry for searching You can use this field for whatever you want For example it can be a serial ...

Страница 12: ...Link System Reporting Turn Job Link System ON to view CAT85 in the Job Link system mobile app see Settings section The Fieldpiece Job Link system app is extremely powerful and ever evolving View live combustion and all saved tests of the current job directly in the app Then email a report quick and easy directly from your mobile device Save and Exit SAVE AND EXIT to save your job and start a new j...

Страница 13: ...g Company Information EDITtoadjustCompanyInformationshown onreports Startup Screen COMBUSTION default JOB MENU FUELTYPE Setwhichscreenyouwanttoseeafterstartcountdowniscomplete Auto Hold Display PUMP STOP default NEVER SelectNEVERtocontinueviewinglivemeasurementswhilethepump isstopped Combustion Setup EDITtoselectparametersandtheirslotsonthe COMBUSTIONscreen Tohideaslotcompletely assignaparameterto...

Страница 14: ...younotice slow response times or when it s visually darker Dust Filters model RFC10 1 Ensure the probe has cooled before opening to avoid contact with hot gas and liquid that may be within the probe 2 Rotate the Filter Cap 1 4 turn counter clockwise to release 3 Pull out the old Probe Filter and replace if needed 4 Pull out the O ring and replace if needed 5 Replace the Filter Cap ...

Страница 15: ... Leaveanewsensorinitspackaginguntilyou rereadytoinstallit 2 Power off CAT85 3 Use a 2 5mm hex key to remove the two socket head screws on the sensor cover labeled SENSOR ACCESS 4 Lift up the bottom of the sensor cover to reveal the gas sensors 5 Pull the old sensor straight out 6 Check and remove the new sensor from its packaging 7 Align and push the new sensor straight in Thesensorcoverwon tclose...

Страница 16: ...Custom x3 Warranty 1 year 4 years sensors only Job Link System Minimum BLE 4 0 devices running iOS 7 1 or Android Kitkat 4 4 Latest compatibility at www fieldpiece com Printer FieldpieceWirelessThermal Printer model CATPR Certifications FCC ID 2ALHRCATX5 IC Industry Canada IC 22518 CATX5 Waste Electrical and Electronic Equipment Sensors Temperature SensorType Type K rod thermocouple fixed Response...

Страница 17: ...resolution 1 ppm CO2 Calculated Range 0 to CO2max vol Best resolution 0 1 vol Excess Air Calculated Range 0 to 999 Best resolution 0 1 Efficiency Calculated Range 0 to 100 Best resolution 0 1 qA Calculated Range 0 to 25 Best resolution 0 1 Dew Point Calculated Range 32 to 212 F 0 to 100 C Best resolution 0 1 F 0 1 C Primary AirTemp Range 32 to 212 F 0 to 100 C Best resolution 0 1 F 0 1 C Accuracy ...

Страница 18: ...or unreasonable use of the analyzer Any implied warranties arising from the sale of a Fieldpiece product including but not limited to impliedwarrantiesofmerchantabilityandfitness for a particular purpose are limited to the above Fieldpiece shall not be liable for loss of use of the analyzer or other incidental or consequential damages expenses or economic loss or for any claim of such damage expen...

Страница 19: ...CAT85 Fieldpiece Instruments Inc 2022 v01 ...

Отзывы: