Fieldpiece CAT45 Скачать руководство пользователя страница 9

17

16

Ambient CO

CO is a very dangerous gas and it’s critical that living spaces are 

clear of carbon monoxide.  

Read “Safety Information” section.

1.  Ensure startup is complete. 

See “Powering On” section.

2.  Select AMBIENT CO from the JOB MENU.

3.  View CO measurement while walking through the living space.

4.  SAVE the measurement displayed.  

“DELETE” temporarily deletes a single value so you can retest. 

“DELETE TEST” deletes the test.

Ambient CO Warning

Vacate the area immediatly if you see the Ambient CO warning. It 

appears if the CO sensor detects a harmful level of CO. The CO warning 

level can be adjusted from the warning screen. 

 

Drafts

CAT45 does not measure draft pressure with the COMBUSTION test, 

but a saved FLUE DRAFT measurement shows during COMBUSTION.  

Draft pressure measurement is important for safety and performance. 

Read “Safety Information” section.

1.  Ensure startup is complete. 

See “Powering On” section.

2.  Select DRAFTS from the JOB MENU.

3.  Mount the CAT45 onto a secure, cool, magnetic surface near the 

sampling point.

4.  ZERO PROBE to zero the probe’s pressure sensor.  

Always remove the probe from the flue before using ZERO PROBE.

5.  Move probe to desired sampling point- DILUTED, FLUE, or 

OVERFIRE. 

6.  View live measurement.

7.  SAVE the measurement displayed.  

“DELETE” temporarily deletes a single value so you can retest. 

“DELETE TEST” deletes the test.

8.  Remove the probe from the sampling point when finished.  

Be careful not to let the metal touch anything until it cools.

Содержание CAT45

Страница 1: ...Fieldpiece Combustion Analyzer OPERATOR S MANUAL Model CAT45 ...

Страница 2: ...gy Inline Water Trap Battery Charging Powering ON Powering OFF Storage Job Menu 14 Combustion Ambient CO Drafts Primary Air Smoke Customer 19 Note Report Save and Exit Job Archive Settings 22 Maintenance 24 General Dust Filter Replacement Sensor Replacement Calibration Specifications 28 Sensors Test Parameters Limited Warranty 32 Sensor Warranty Obtaining Service ...

Страница 3: ...nless a visual inspection ensures it s safe to do so Ensure any connections to fuel sources are leak free Do not touch or store probe until it cools to ambient temperature Condensate may be acidic Combustion gases may be toxic even in low concentrations Seal any equipment holes used during testing in order to prevent dangerous flue gas entering the space CAUTION Do not use or store near solvents D...

Страница 4: ...orVault technologysealstoprolongsensor life Features 4 Year Gas Sensor Warranty Large Intuitive Touchscreen Powerful Trending SensorVault Technology Inline Water Trap Rechargeable Battery In use USB C Charging Field Replaceable Smart Sensors Job Link System App Compatible Wireless Printer CATPR Compatible Durable Hard Lined Case What s Included Combustion Analyzer Probe Hard Lined Carrying Case Ex...

Страница 5: ...robe Connection Touchscreen LCD Inline Water Trap Gas Sensor Cover 2 2 5mm Hex Sockets 4 Magnetic Mounts Click Power Button SensorVault Technology Threaded Probe Cone Lock Filter Cap 1 4 turn Sensing Point Flue Gas Inlet Temperature Sensor Probe Pressure Filter O ring ...

Страница 6: ...r design and therefore their ideal sampling points However there are commonalities that make for useful guidelines when analyzing performance Heed equipment manufacturer instructions above anything mentioned in this manual Before inserting the probe in the flue it s good practice to test for excessive soot which may lead to carbon buildup within the analyzer or overexpose sensors Use the probe con...

Страница 7: ...testroomandaway fromanyvehicleexhaustwheretracesofCOcouldbelingering DonotrelyontheanalyzeralonetocheckforunsafeCOlevels 3 Fully press the power button down until you feel and hear the click of the SensorVault technology UNSEAL the sensors Pressdeeperifitdisplays SEALED 4 Wait for start countdown to complete 5 Start testing See JobMenu section Powering OFF Read SafetyInformation section 1 Complete...

Страница 8: ...nts Forbestresults testforatleast5minutesnearthecenterofthe flue whereyoufindthehighestlevelofCO 7 SAVE ALL measurements displayed 8 Remove the probe and cone from the flue when finished Becarefulnottoletthemetaltouchanythinguntilitcools Reference Ranges When selecting equipment the reference range icon shows when available Temperature O2 CO and CO air free all have reference ranges These ranges s...

Страница 9: ...en Drafts CAT45 does not measure draft pressure with the COMBUSTION test but a saved FLUE DRAFT measurement shows during COMBUSTION Draft pressure measurement is important for safety and performance Read SafetyInformation section 1 Ensure startup is complete See PoweringOn section 2 Select DRAFTS from the JOB MENU 3 Mount the CAT45 onto a secure cool magnetic surface near the sampling point 4 ZERO...

Страница 10: ...flue This is good practice when dirty combustion is expected in order to extend the life of CAT45 and equipment A third party smoke tester is needed Read SafetyInformation section 1 Ensure startup is complete See PoweringOn section 2 Select SMOKE from the JOB MENU 3 Use your smoke tester to find the smoke level 4 Select the corresponding level on screen 5 SAVE the smoke level DELETE deletestheentr...

Страница 11: ...Link System Reporting Turn Job Link System ON to view CAT45 in the Job Link system mobile app see Settings section The Fieldpiece Job Link system app is extremely powerful and ever evolving View live combustion and all saved tests of the current job directly in the app Then email a report quick and easy directly from your mobile device Save and Exit SAVE AND EXIT to save your job and start a new j...

Страница 12: ...g Company Information EDITtoadjustCompanyInformationshown onreports Startup Screen COMBUSTION default JOB MENU FUELTYPE Setwhichscreenyouwanttoseeafterstartcountdowniscomplete Auto Hold Display PUMP STOP default NEVER SelectNEVERtocontinueviewinglivemeasurementswhilethepump isstopped Combustion Setup EDITtoselectparametersandtheirslotsonthe COMBUSTIONscreen Tohideaslotcompletely assignaparameterto...

Страница 13: ...younotice slow response times or when it s visually darker Dust Filters model RFC10 1 Ensure the probe has cooled before opening to avoid contact with hot gas and liquid that may be within the probe 2 Rotate the Filter Cap 1 4 turn counter clockwise to release 3 Pull out the old Probe Filter and replace if needed 4 Pull out the O ring and replace if needed 5 Replace the Filter Cap ...

Страница 14: ... Leaveanewsensorinitspackaginguntilyou rereadytoinstallit 2 Power off CAT45 3 Use a 2 5mm hex key to remove the two socket head screws on the sensor cover labeled SENSOR ACCESS 4 Lift up the bottom of the sensor cover to reveal the gas sensors 5 Pull the old sensor straight out 6 Check and remove the new sensor from its packaging 7 Align and push the new sensor straight in Thesensorcoverwon tclose...

Страница 15: ...5 meters FuelTypes Natural Gas Propane LPG Oil 2 Light Oil 6 Heavy Biofuel Coal CoalTown Gas Coking Oven Gas KOKS Custom x3 Warranty 1 year 4 years sensors only Job Link System Minimum BLE 4 0 devices running iOS 7 1 or Android Kitkat 4 4 Latest compatibility at www fieldpiece com Printer FieldpieceWirelessThermal Printer model CATPR Certifications FCC ID 2ALHRCATX5 IC Industry Canada IC 22518 CAT...

Страница 16: ...0 to 0 8 inWC Best resolution 0 01 inWC Accuracy 0 02 inWC CO Air Free Calculated Range 0 to 4000 ppm Best resolution 1 ppm CO2 Calculated Range 0 to CO2max vol Best resolution 0 1 vol Excess Air Calculated Range 0 to 999 Best resolution 0 1 Efficiency Calculated Range 0 to 100 Best resolution 0 1 qA Calculated Range 0 to 25 Best resolution 0 1 Dew Point Calculated Range 32 to 212 F 0 to 100 C Bes...

Страница 17: ...or unreasonable use of the analyzer Any implied warranties arising from the sale of a Fieldpiece product including but not limited to impliedwarrantiesofmerchantabilityandfitness for a particular purpose are limited to the above Fieldpiece shall not be liable for loss of use of the analyzer or other incidental or consequential damages expenses or economic loss or for any claim of such damage expen...

Страница 18: ...35 34 Intentionally Blank Intentionally Blank ...

Страница 19: ...CAT45 Fieldpiece Instruments Inc 2022 v01 ...