Maintenance
Clean the exterior with a dry cloth.
Do not use liquid.
Battery Replacement
When "LO BATT" LED is flashing,
the battery should be replaced. Turn
your ACM4 off and replace the 9V
battery.
Check Your Sensor:
Coffee Cup CO Test
To demonstrate that your CO
sensor works, turn a ceramic coffee
cup upside down and slide it over
the edge of a counter (or desk) to
expose about a third of the mouth of
the cup. Burn a cigarette lighter inside
the exposed mouth of the cup. Don't
burn the counter.
When the flame starts to flicker,
you've burned up most of the oxygen
in the cup creating carbon dioxide
and now you're starting to produce
carbon monoxide. Bring the flame in
5. If the sensor is incorrectly installed,
"ON" LED and "LOW BATT" LED will
blink alternately and after 5sec, the
ACM4 will auto power off.
Sensor Disposal
The RCM4 Replacement carbon
monoxide smart sensor contains
sulfuric as well as precious metals. The
sensor should be recycled properly
through a local electronic waste
center.
Limited Warranty
This meter is warranted against
defects in material or workmanship
for one year from date of purchase.
Fieldpiece will replace or repair the
defective unit, at its option, subject
to verification of the defect.
This warranty does not apply to
defects resulting from abuse, neglect,
accident, unauthorized repair,
alteration, or unreasonable use of the
instrument.
Any implied warranties arising
from the sale of a Fieldpiece product,
including but not limited to implied
warranties of merchantability and
fitness for a particular purpose, are
limited to the above. Fieldpiece shall
not be liable for loss of use of the
instrument or other incidental or
consequential damages, expenses, or
economic loss, or for any claim of such
damage, expenses, or economic loss.
State laws var y. The above
limitations or exclusions may not
apply to you.
For Service
I n t h e U S A , c a l l Fi e l d p i e ce
Instruments for one-price-fix-all out
of warranty service pricing. Send
check or money order for the amount
quoted. Send the meter freight
prepaid to Fieldpiece Instruments.
Send proof of date and location of
purchase for in-warranty service. The
meter will be repaired or replaced,
at the option of Fieldpiece, and
returned via least cost transportation.
Outside of the USA, please visit www.
fieldpiece.com for service contact
information.
www.fieldpiece.com
©Fieldpiece Instruments, Inc 2013; v08
More Instruments
from Fieldpiece
and out of the mouth of the coffee
cup to just keep the flame alive. The
longer you keep the flame flickering,
the more CO you produce.
After 10 seconds of flickering,
extinguish the flame and put the CO
head in the mouth of the cup. You
should see readings in the 100s. Take
it out if it approaches 1000PPM.
CO Sensor Replacement
The ACM4 uses a carbon monoxide
smart sensor. If you are seeing erratic
CO readings or no readings in a
known CO environment, you likely
need to replace the sensor.
1. Obtain replacement sensor model
RCM4 from your local distributor.
2. Remove sensor cap by removing the
4 screws.
3. Directly pull out old sensor.
4. Hold the new sensor by the sides.
While holding the sensor on the
sides; press down to secure the new
sensor. Do not press the new sensor
from the top.
Air Velocity
& Temperature
Head
English
READ
LO BATT
ON
LCD X
100
Average
(16 sec)
Metric
Real
time
AAV3
AUTO-
OFF
English
Metric
Ft/min
M/s
KM/hr
MPH
ºF
ºC
OFF
APO
MAXMIN HOLD SET
CO2
EA
MAX
°F
%
%
°C
ENTER
AUTO-OFF
°F
°C
TEMP CAL
PRESS FOR
1 SECOND
SOX3
Combustion
Check
Excess Air,
%CO
2
and %O
2
Natural
Gas
Oil
#2
Propane Custom
EXHAUST
CLEAR
SET CUSTOM
ON/OFF
FUEL
MAX/MIN
MEASURE/HOLD
ADMN2
Dual-Port
Manometer
Accessory
Head
P1
P2
P1-P2
ON
0.1
ENGLISH
METRIC
0.01
(LCD/10)
Lo Batt
Resolution
ZERO
AUTO
OFF
P1
P2
80
AAT3
In-Duct
Psychrometer
& Air Velocity
Head
ON
LO BATT
AVG
ENGLISH
ENGLISH METRIC
RH%
Ft/min
°F
RH%
M/s
°C
METRIC
DRY BULB
WET BULB
DEW POINT
AVG
NORMAL
AUTO OFF
MICRONS OF MERCURY
SVG3
VACUUM
GAUGE
MIN
ALARM
ENTER
CAT.III
300V
400A
CLAMP
ACH4
AC Current
Clamp
1AAC / 1mVAC
400AAC MAX
!
ET2W
LO BATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
FUSED
200mA
MAX
FUSED
30V
MAX
WIRELESS
ENABLED
MAX/MIN
SYNC
HOLD
CAT.III
MAX
600V
15 SEC FOR 500mV
RANGE
AUTO-OFF
500
600
600
50
5000m
500m
500µ
50m
200m
200m
500m
5000m
50m
50500
500µ
500
750
500
1400
200
2
K
200
20
M
2
K
200
K
20
RECV
Digital Refrigerant Manifolds
Accessory Heads
Combustion Check with AutoPump
Wireless Measurements
Vacuum Gauge
Carbon
Mono
xide
Accesso
ry
Head
ON
AVERAG
E
LOW BA
TT
ON
Carbon
Mono
xide
Accesso
ry
Head
Carbon
Mono
xide
Accesso
ry
Head
ON
AVERAG
E
LOW BA
TT
ON
Inc
orr
ect