General safety instructions

1. GENERAL SAFETY REGULATIONS

Important safety notice

  Carefully unpack the product and take care not to throw away any part of the packaging until all the product 

parts have been identifi ed.

  Read all warnings and instructions. Not following warnings or instructions may lead to injury from an electric 

shock, fi re and/or serious injuries.

 

ATTENTION!

 Protect yourself against electric shocks!

Packaging

The device is contained in a package intended to prevent any damage during transport. This package is 
a resource and so it can be handed over for recycling.

User manual

Before fi rst using the pump, please read the following safety instructions and the User manual. Learn about all 
the parts and the correct use of the device. Keep the User manual in a safe place where it can be easily found for 
future use. If giving the device to somebody else, do so together with the User manual. Following the instructions 
in the included User manual is a prerequisite for safe use of the garden appliance. The User manual also contains 
operating, maintenance, and repair instructions.

 

NOTE:

 If you hand over the appliance to somebody else, do so together with this user’s manual.

Make sure you use the appliance properly by following the instructions in the included User manual. The User 
manual also contains operating, maintenance, and repair instructions.

Electrical safety

The pump can be connected to any power plug installed according to the given norms.
The plug must be powered at 230 V ~ 50 Hz.

 

ATTENTION!

 Important for the protection of your personal safety. Before fi rst starting your new submersible 

pump, have a professional check the following items:
• Grounding
• Neutral conductor

 

The current circuit breaker must conform to energy safety norms and must fully function correctly.

 

The electrical connection must be protected against moisture.

 

If there is a risk of the electrical connection being fl ooded, it must be moved higher.

 

• In all situations, prevent the circulation of aggressive liquids and coarse materials.

 

• The pump must be protected against frost.

 

The pump must be protected against running when empty.

 

Prevent children from accessing parts of the pump by taking the appropriate measures.

The manufacturer will not accept any responsibility for accidents or damage resulting 
from not following the instructions in this manual.

Содержание FVC 8510 EC

Страница 1: ...FVC 8510 EC FVC 8550 EC...

Страница 2: ...ERAL SAFETY INSTRUCTIONS 4 Important safety notice 4 Packaging 4 User manual 4 Electrical safety 4 2 DESCRIPTION OF THE POWER TOOL 5 3 OPERATING INSTRUCTIONS 6 Purpose of use 6 4 INSTALLATION 7 Pressu...

Страница 3: ...maintenance and repair instructions NOTE If you hand over the appliance to somebody else do so together with this user s manual Make sure you use the appliance properly by following the instructions...

Страница 4: ...HE POWER TOOL Fig 1 1 Outlet hole 1 female screw joint 2 Supply de aeration hole s plug 3 De aeration hole 4 Inlet hole 1 female screw joint 5 Drain hole plug 6 Drain hole 7 Main power switch 8 Ventil...

Страница 5: ...ned out of the reservoir i e when the water taps are open etc the pressure inside the rubber reservoir as well as inside the pressure tank 11 drops If the pressure drops by 1 4 bar the automatic switc...

Страница 6: ...meter should not be smaller than the inlet hole 4 The inlet hole is equipped with 1 female thread Screw the suction hose with 1 male thread onto the ori ce A check valve should be always mounted on th...

Страница 7: ...he aggregate with a 1 female screw joint not included in the package which must be screwed onto the output threaded hole 1 F3 It is recommended to install a check valve F2 b not included in the packag...

Страница 8: ...be repeated whenever the equipment has been left unused for a prolonged period of time or whenever air gets inside the system NOTE Make sure that the pump is fully ooded along the entire length of th...

Страница 9: ...ep all nuts bolts and screws tightened This will ensure conditions for the safe operation of the equipment For safety reasons replace worn out or damaged parts Always use only original spare parts Par...

Страница 10: ...r the lters are blocked A Fill the pump with water and pay attention to any leaks of air by unscrewing the de aerating closure B Flood the suction hose Make sure that no section of the suction hose is...

Страница 11: ...2 4 kg 9 DISPOSAL INSTRUCTIONS AND INFORMATION ON DISPOSING OF USED PACKAGING MATERIALS Dispose of used packaging material at a site designated for waste in your municipality The appliance and its acc...

Страница 12: ...220 240 V 50 Hz 800 W IPX4 The product is inline with directives and regulations listed below Directive for low voltage electrical equipment LVD 2014 35 EU Directive for Electromagnetic Compatibility...

Страница 13: ...W IPX4 The product is inline with directives and regulations listed below Directive for low voltage electrical equipment LVD 2014 35 EU Directive for Electromagnetic Compatibility EMC 2014 30 EU and n...

Страница 14: ......

Страница 15: ......

Страница 16: ...10 A FAST Hungary Kft 2310 Szigetszentmikl s K ntor u 10 mint a term k magyarorsz gi im port rea j t ll si jegyen felt ntetett t pus s gy r t si sz m k sz l kre j t ll st biztos t a fogyaszt k sz m r...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Отзывы: