WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire

®

 Air Purifying System out of the plenum

. Avoid touching the glass portion of the lamp with your hands.

Remove base unit and cover from box.

3. 

Apply supplied “Duct Seal Kit” according to instructions included in kit. 

4. 

(See Figure 12)
Determine whether to use flat or angled bracket. (Refer to UV-Aire 

5. 

Configurations in Section III for aid in this decision)

Flat Bracket Installation

a. 

    i. Remove the two hex nuts and flat bracket from included  
       bagged hardware.
     ii. Install the flat bracket and secure to the unit base with the hex nuts 
        provided. (See Figure 13) 

Angled Bracket Installation

b. 

NOTE:

 For angled bracket mounting, refer to specifications outlined by 

Diagrams A & B for mounting distances in the “Angled Lamp Mounting Bracket 
Specifications” in section III.
  

  i. Remove the two hex nuts and angled bracket from included 

 

     bagged hardware.

  

  ii. Install the angled bracket and secure to the unit base with the hex 

 

     nuts provided. (See Figure 14)

NOTE:

 Be sure to note location of lamp hole in bracket relative to unit base.

Mount the unit base to the duct using the four mounting screws provided. (See 

6. 

Figure 15)
Remove tag and alcohol from lamp. Wipe off lamp being sure not to 

7. 

touch lamp with bare hands. The oils in your hands may cause the lamp to 
prematurely expire.
Insert lamp through hole until lamp cannot be inserted any further.  

8. 

(See Figure 16)
Swing swivel bracket over end of lamp. Hand-tighten the wing nut on stud. 

9. 

(See Figure 17) Be careful not to over tighten the wing nut. The porcelain at 
the lamp base may crack when over tightened.
Plug ballast plug into end of lamp. (See Figure 18)

10. 

Figure 16

Figure 18

Figure 17

Figure 15

Figure 14

Figure 12

Figure 13

Содержание UV-Aire UV-18X

Страница 1: ...et 2 Wing nuts Caution Labels Gasket SAFETY CONSIDERATIONS WARNING Never expose eyes or skin to UV C light from any source Looking directly at the UV C light may cause permanent eye damage or blindnes...

Страница 2: ...mounting bracket o Figure 1 INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment...

Страница 3: ...X DUCT For installations on duct systems with a metallic main duct and flex duct branches follow the instructions in figure 2A below IF YOU HAVE METAL DUCT Apply supplied wet and stick mounting templa...

Страница 4: ...nting plate onto the duct with duct tape in either vertical or horizontal a position See Figure 3 Bend tabs outward See Figure 4 b Using a knife or blade cut out a rectangular opening in the duct usin...

Страница 5: ...utlined by Diagrams A B for mounting distances in the Angled Lamp Mounting Bracket Specifications in section III i Remove the two hex nuts and angled bracket from included bagged hardware ii Install t...

Страница 6: ...e configurations chart below when making your selection Replace cover on unit Tighten side screws See Figure 19 20 11 Plug the power cord into a standard electrical outlet 12 NOTE Seal the joints and...

Страница 7: ...y for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste After replacing lamp make sure a new Lamp Replac...

Страница 8: ...sed 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty...

Отзывы: