Field Controls UV-AIRE UV-1500C Скачать руководство пользователя страница 3

page 3

WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire

®

 Air Purifying System out of the plenum

. Avoid touching the glass portion of the lamp with your hands.

FOR AREA OR ROOM OPERATION

Place the UV-1500C in the desired area; plug the power cord into a 

1. 

standard 120-volt wall receptacle.
Turn the speed control knob clockwise to turn on the unit and to adjust the 

2. 

motor/fan speed to the desired airflow. (See Figure 1)
After the fan has started, the LED light will show a continuous “GREEN” 

3. 

color indicating proper unit operation.

Figure 1

Figure 5

Figure 4B

Figure 4A

Figure 3

Figure 2

WALL MOUNTING OPTION

 (The UV-1500C is supplied with four mounting brackets to allow the unit to be 

mounted onto a wall).

To install the mounting brackets, remove the eight mounting screws from the back of the UV-1500C.  

1. 

(See Figure 2)
Install the four mounting brackets onto the back of the housing securing them with the mounting screws 

2. 

you just removed. (See Figure 3)
Determine the desired location on the wall (a 120-volt wall receptacle should be within 5 feet of the unit) 

3. 

and mark the mounting screw locations based on the dimensions given in figure 4A.
Install four drywall anchors or other appropriate fasteners rated for at least a 15 lb. load capacity.  

4. 

(See Figure 4B)
Mount the unit to the wall. (See Figure 5)

5. 

Plug the power cord into a standard 120-volt wall receptacle. Turn the speed control knob clockwise to 

6. 

turn on the unit and adjust the motor/fan speed control to the desired airflow.
After the fan has started the LED light will show a continuous “GREEN” color indicating proper  

7. 

unit operation.

Содержание UV-AIRE UV-1500C

Страница 1: ...on Date Installed By Phone UV AIRE AIR PURIFYING SYSTEM Model UV 1500C ITEMS INCLUDED IN KIT 1 UV Aire UV 1500 unit 10 sheet metal mounting screws 2 drop ceiling cover plates 4 wall and drop ceiling mounting brackets 1 Ultra Violet lamp 1 instruction sheet 1 2x4 electrical conduit box and cover 4 intake air filters 1 carbon filter For best results operate the UV 1500 continuously 24 hours a day UV...

Страница 2: ...afety shut off switch that disconnects power to the fan and the lamp if the front 2 access door is opened The UV 1500C is equipped with a circuit board to monitor the operation of the UV lamp it indicates the 3 operation of the lamp through an LED indicator light mounted on the front access door The circuit board indicates good operation of the lamp by a continuous GREEN color on the LED light Aft...

Страница 3: ...our mounting brackets to allow the unit to be mounted onto a wall To install the mounting brackets remove the eight mounting screws from the back of the UV 1500C 1 See Figure 2 Install the four mounting brackets onto the back of the housing securing them with the mounting screws 2 you just removed See Figure 3 Determine the desired location on the wall a 120 volt wall receptacle should be within 5...

Страница 4: ...oot ceiling tile space 23 3 4 Align the edges of the extension cover to the front of the UV 1500C body and use the holes in the cover as a template to mark the mounting hole locations on the UV 1500C body See Figure 6 Drill a 3 1 8 hole into the body of the UV 1500C at the marked locations See Figure 7 Secure the extension covers the UV 1500C body with the supplied metal screws See Figure 8 9 4 Re...

Страница 5: ...auge wire or other 10 suspended ceiling support method between the installed ceiling anchors and the four mounting brackets on the back of the UV 1500C See Figure 14 Wire the UV 1500C in accordance with the National Electrical Code manufacturer s recommendations 11 and or applicable local codes UNIT MUST BE GROUNDED Check ground circuit to make certain that the unit has been properly grounded The ...

Страница 6: ...oor to open See Figure 18 3 Unplug ballast plug from end of lamp and loosen the wing nut on swivel bracket Swing swivel bracket 4 away from the lamp See Figure 19 Remove lamp carefully by sliding the lamp to the left through the hole on the left side of the chamber 5 After exposing the connection end of the lamp inside the chamber remove the lamp through the front of the unit NOTE When replacing t...

Страница 7: ...nd press and hold the timer reset button on the circuit board for 30 45 seconds See Figure 20 After releasing the timer reset button the LED on the front of the unit will flash twice indicating the timing circuit has been reset Release the door switch turn the knob on the speed control to the off position and close the front cover of 11 the unit Secure the cover with the door mounting screws Turn ...

Страница 8: ...uality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company postage prepaid 5 IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR SIMILAR DAMAGES INCLUDING BUT NOT LIMITED TO LOST PROFITS OR REVENUE INABIL...

Отзывы: