Field Controls UV-Aire 46511500 Скачать руководство пользователя страница 2

page 2

WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness.

Never operate the UV-Aire Air Purifying System out of the plenum

. Avoid touching the glass portion of the lamp with your hands.

WARNING:

 Never expose eyes or skin to UVC light from any source.

Looking directly at the UVC light may cause permanent eye damage or blindness. 

• 

Never operate the UV-Aire Air Purifying System out of the plenum.

• 

Designed for a closed duct system. Do not mount near a supply or a return air opening.

• 

All duct openings in direct line of site of the UV light must be sealed with aluminum tape or  

• 

   equivalent sealing methods.

 

 
WARNING:

 UV light will break down plastic materials not rated for UV exposure:

(Examples: wire insulation, flex duct, drain pans and humidifiers)

The unit must be mounted at least 30" from the above stated type of materials.

• 

 If it is necessary to mount the unit in direct line of sight of these types of materials, they must  

• 

   be shielded with aluminum foil, aluminum foil tape, or sheet metal.

 
WARNING:

 DO NOT mount this unit outdoors.

This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.). 

• 

 

WARNING:

 Never touch broken lamp or internal contents of lamp. The lamp contains mercury.

After opening the carton, unpack and inspect the unit and lamp for damage. Do not install  

• 

   this unit if any damage is noticeable.  If lamp is damaged, cracked or broken, do not touch  

   lamp or other contents in carton. Close carton and return to seller immediately.

In case of accidental exposure to internal contents of lamp, wash hands and any other    

• 

   affected skin area with mild detergent. Remove affected clothing immediately.  If skin surface  

   is pierced, seek medical attention immediately.

NOTE:

 If you touch the glass of the lamp, you should wipe the glass clean with isopropyl alcohol  

and a lint free wipe. If the lamp is not cleaned, the film of hand oils causes a reduction in the  

light intensity.

 
WARNING:

 Before installing or servicing a humidifier, air filter, HVAC system, or this unit, etc., 

always turn all power OFF and have unit unplugged. Electrical shock can cause personal injury or 

death. Never expose eyes or skin to direct UVC light from any source.

 
WARNING:

 To prevent water damage or electric shock, do not mount unit under a humidifier.

WARNING:

 This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, 

etc.). For use on gas fired, oil fired, electric and split system heat pump forced air systems*. This 

product is NOT designed to be mounted outside on gas fired or heat pump packaged units**.

*Split system heat pumps are systems where the air handler and the air conditioning compressor are  
   separate units.
**Packaged units are systems where the air handler and the air conditioning compressor are built together 
     and are installed outside of the building.

SAFETY CONSIDERATIONS

Содержание UV-Aire 46511500

Страница 1: ...for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION Installation Date Installed By Phone UV AIRE AIR PURIFYING SYSTEM Model UV 16 120 The UV Aire unit is designed to emit powerful UVC band light rays which sterilize and redu...

Страница 2: ...and lamp for damage Do not install 0 this unit if any damage is noticeable If lamp is damaged cracked or broken do not touch 0 lamp or other contents in carton Close carton and return to seller immediately In case of accidental exposure to internal contents of lamp wash hands and any other 0 affected skin area with mild detergent Remove affected clothing immediately If skin surface 0 is pierced se...

Страница 3: ...ATION Locate a suitable location for the unit 1 downstream from the A coil in the supply plenum or in the return plenum preferably downstream from the air filter For optimum cleaning effect on the A coil mount the unit in the supply plenum as close as possible to the A coil See Figure 1 CAUTION Investigate and determine the location of the A coil prior to drilling holes in duct for mounting unit N...

Страница 4: ...ate See Figure 3 Using a 5 1 4 to 1 2 drill bit drill a viewport hole as indicated on the template See Figure 3 Optional Light Shield The light shield may be mounted at virtually any angle However when 6 deciding on a suitable location the mounting screw head can not be in the shaded area of template See Figure 4 Press shield onto duct wall then secure with screws See Figure 5 7 Attach the UV Aire...

Страница 5: ...lockwise 90º Do not wire the unit into the appliance fan circuit Premature 12 failure of the ballast and lamp will occur The warranty will be voided Plug the power supply cord into a standard 120VAC electric outlet Check lamp operation by looking through the viewport hole NOTE The viewport hole is made of glass and will not allow any UVC rays to pass through A blue glow should be seen in the duct ...

Страница 6: ...re hands Oils on the hands tend to reduce lamp intensity Wipe off the glass with the supplied alcohol wipe 5 Position the ballast assembly power cord 90 to the viewport hole on the 6 mounting base See Figure 9 Slide the lamp though the hole in the mounting base See Figure 7 7 Press the ballast against the mounting base Rotate the ballast assembly clockwise until it stops and is 8 locked in place S...

Страница 7: ...ment authority for local disposal or recycling requirements 4 According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste Wash hands and remove and wash clothes for added safety measures 5 For replacement parts contact Field Controls at Phone 1 252 522 3031 Fax 1 252 522 0214 Email sales fieldcontrols com LAMP Replacement Part Number 46511200 TROUBLESHO...

Страница 8: ...roof of purchase sales receipt identifying the Product purchased Product model or accurate date code information and the date the Product s was purchased 3 Product whose warranty quality stickers Product serial number plates or electronic serial numbers have been removed altered or rendered illegible shall not be covered under the limited warranty 4 Defective Product must be returned to Company po...