WARNING:

 

Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage 

or blindness.Never operate the UV-Aire

 Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

 

e.    Insert the Duo unit into the duct opening and attach it to the duct (or Ductboard Adapter 

 

 

  Plate) with the four included sheet metal screws.  The wider end of the V-shape of the Duo 

 

 

  unit should face into the oncoming airstream.  Note:  The white plastic base has a round sight  

 

 

  glass hole for observing the lamp inside the duct (the sight glass may be seen above the center 

 

 

  hole in the mounting base in Figure 2).  In Figure 2, the unit is installed properly for a 

 

 

  downward air fl ow direction (note that the round sight glass hole will be upstream of the 

 

 

  ballast when properly installed).

 

f.     Insert the UVC lamp pins into the ballast socket (see Figure 3).  Note:  the lamp has one 

 

    long pin that must be aligned with the recessed terminal in the ballast socket.  D o NOT directly 

 

    touch the bulb lamp glass section with bare hands.  Wear oil-free, cotton type gloves when han

 

    dling germicidal glass bulb.

Figure 2

Figure 3

 

g.    Carefully insert the lamp through the center of the white plastic mounting base, align the 

 

 

  ballast with the power cord pointing 90 degrees to the right of the round sight glass, and  

 

 

 

 

  engage the ballast onto the base by rotating the ballast ¼ turn to the right (see fi gures 4 

 

 

  and 5).  Note:  the safety switch actuating fi nger that projects from the mounting base 

 

 

  must engage into the slot in the inside of the ballast.  The slot is visible above the ballast 

 

 

  socket in Figure 3.

Figure 4

Figure 5

Содержание DUO-11/24V

Страница 1: ... 11 24V DUO 14 24V PCUV 16UA The Duo 24V models produce germicidal UVC Band light rays which sterilize and reduce airborne microorganisms and reduce Volatile Organic Compounds VOC s by a photocatalytic chemical reaction as air passes through a heating or air conditioning system It is installed in the main supply or return duct and operates continuously to automatically purify the air in the home 2...

Страница 2: ...do not touch lamp or other contents in carton Close carton and return to seller immediately In case of accidental exposure to internal contents of lamp wash hands and any other affected skin area with mild detergent Remove affected clothing immediately If skin surface is pierced seek medical attention immediately NOTE If you touch the glass of the lamp you should wipe the glass clean with isopropy...

Страница 3: ...ctboard when installed using the included Ductboard Adapter Plate see Figure 1 2 Install the Duo 24V unit a Hold or temporarily tape the included Ductboard Adapter Plate in the location chosen for installation and using the plate as a template mark the mounting surface using the outermost slots in the plate see Figure 1 Alternatively a 5 3 8 square may be marked on the mounting surface b Cut out t...

Страница 4: ...a downward air flow direction note that the round sight glass hole will be upstream of the ballast when properly installed f Insert the UVC lamp pins into the ballast socket see Figure 3 Note the lamp has one long pin that must be aligned with the recessed terminal in the ballast socket D o NOT directly touch the bulb lamp glass section with bare hands Wear oil free cotton type gloves when han dli...

Страница 5: ... annually The lamp should operate continuously for maximum lamp life and light effectiveness 3 Ensure that power has been disconnected to the circuit that will provide power to the 24V transformer and install the transformer as directed in the installation instructions included with the transformer WARNING MAKE SURE POWER IS DISCONNECTED TO THE CIRCUIT TO BE USED TO PROVIDE POWER TO THE DUO 24V UN...

Страница 6: ... ballast against the mounting base Rotate the ballast assembly clockwise until it stops and is locked in place See Figure 8 9 After assembly is firmly in place reconnect power to transformer Check lamp operation by looking through the viewport hole A blue glow should be seen in the duct 10 After replacing the lamp make sure to install the Lamp Replacement Label Print the date on the label and appl...

Страница 7: ...ngaged 4 If lamp does not light up remove the ballast from the base and re install it onto the base ensuring that the finger projecting from the base engages into the safety switch slot in the ballast Repeat step 3 5 If lamp does not light up after performing Steps 3 and 4 replace lamp REPLACEMENT PARTS LIST For replacement parts contact Field Controls at Phone 252 522 3031 Fax 252 522 0214 Email ...

Страница 8: ...46648100 06 15 The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL Warranty For warranty information about this or any Field Controls product visit www fieldcontrols com warranty ...