13. Close the cover and tighten cover screw. (See Figure 21)
14. Plug the power cord into a standard electrical outlet.
NOTE:
Seal the joints and seams of the plenum near the mounting location to reduce any direct
viewing of light. (See Figure 1)
15. Press the power switch to the “ON” position. (Light on switch should be on indicating power.)
16. Look through view port in the box cover to be sure the lamp is working. You should see a blue
glow. (The view port is covered with a plastic lens that blocks the UVC rays.) If equipped, the
LED light will show a continuous “GREEN” color indicating proper unit operation.
17. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical
support at 1-252-522-3031 for further assistance.
IV.
INCORPORATING A THERMOSTAT
(Be sure to follow any applicable state or local codes)
The UV Aire units supplied with a circuit board allows for the automatic operation of the UV lamp when the there is a
call for heating or cooling by the thermostat. After the call for heat has been satisfied, the UV Aire unit will operate for
45 minutes then shut off.
1. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring.
2. Loosen the cover screw and open the unit cover.
3. Locate terminals 1-2 on the circuit board and remove the jumper wire.
4. Wire to terminals W, C and G into the fan center on the furnace. Refer to Diagram A for proper wiring.
5. Close the cover and secure with the cover screw. Then plug the UV Aire back into the power receptacle and
switch the power switch to the “ON” position
S
YSTEM CHECK OUT PROCEDURE
:
1. With the thermostat set to the heating mode, adjust the thermostat for a call for heat. The furnace and the UV Aire
should start operating. Turn down the thermostat to stop the call for heat. After 45 minutes, the UV Aire lamp will
turn off.
2. With the thermostat set to the cooling mode, adjust the thermostat for a call for cooling. The furnace and the UV
Aire should start operating. Turn up the thermostat to stop the call for cooling. After 45 minutes, the UV Aire
lamp will turn off.
WARNING:
Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness.
Never operate the UV-Aire™ Air Purifying System out of the plenum
. Avoid touching the glass portion of the lamp with your
hands.
Figure 21