WIRING
(See Diagrams A-C State Industries Water Heaters)
Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's recommendations
and/or applicable local codes. UNITS MUST BE GROUNDED. Check ground circuit to make certain that the unit has
been properly grounded. The wiring should be protected by an over current circuit device rated at 15 amperes. CAUTION
must be taken to ensure that the wiring does not come into contact with any heat source. All line voltage and safety
control circuits, between the venter and the appliance, MUST be wired in accordance with the National Electrical Code for
Class I wiring or equivalent methods.
NOTE:
Route low voltage wiring through the supplied plastic grommet.
M
INIMUM
L
INE
V
OLTAGE
W
IRE
N
O
. 14 A
WG
1. You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric
utility requirements when you intall this wiring.
2. This water heater must be electrically ‘grounded” by the installer. Using a screw on the water heater junction box, a
wire must be run to connect the water heater to an uninterrupted metallic ground.
3. This appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the
latest edition of the National Electrical Code ANSI/NFPA No. 70.
NOTE:
If any of the original wire as supplied with the water heater must be replaced, it must be replaced with 105°C
thermoplastic AWM wire or its equivalent.
Models: F75-120, F75-140, F30-150, F80-180, F30-199, F80-199, F100-199ES, F100-199ET, F30-225, F75-250, F100-
260ES, F100-260ET, F75-300, F70-360
N
ATURAL
A
ND
P
ROPANE
(L.P.) M
ODELS
CAUTION:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.