background image

 

About this manual 

About the contents of this manual 

The information in this document may be changed at any time without notice. 

 

 

 

 

Table of Contents 

 

About the contents of this manual 

i

 

Table of Contents 

i

 

Version and revision history. 

1

 

Revision history for product: 

1

 

Revision history for this document. 

1

 

Document properties. 

1

 

Author. 

1

 

Functional 

2

 

IEEE C37.94 

2

 

G.703 Codirectional interface - Codir 

2

 

Features 

3

 

Fiberoptic and data transfer protocol 

3

 

Power Supply 

3

 

Physical size 

3

 

Environmental conditions 

3

 

Unpacking. 

4

 

Product 21-216 consists of: 

4

 

Installation. 

6

 

Serial number. 

6

 

Connections on Rear side panel. 

6

 

G.703 64kbit/s Codir Port. 

7

 

Functional earth/ground. 

7

 

Configuration 

8

 

Start and usage. 

8

 

Power on. 

8

 

LED-status. 

8

 

PSU1 

8

 

CHANNEL 

8

 

RA 

9

 

LA 

9

 

ERR 

9

 

LF 

9

 

LT 

9

 

RxF 

9

 

RxT 

9

 

PSU2 (Optional second power supply)  9

 

Alarm 

9

 

Technical support 

10

 

CE - mark 

10

 

Содержание 21-216

Страница 1: ...FS18132 Technical manual 21 216 Secure Series R1 v3 Fiber Optical Converter 21 216 Secure Series G 703 Codir IEEE C37 94 Technicalmanual...

Страница 2: ...or 1 Functional 2 IEEE C37 94 2 G 703 Codirectional interface Codir 2 Features 3 Fiberoptic and data transfer protocol 3 Power Supply 3 Physical size 3 Environmental conditions 3 Unpacking 4 Product 2...

Страница 3: ...n history for this document Revision AK0 2018 01 30 LaJo document created Revision R1 2018 02 02 OsLi Product released for serial production Document properties Last saved 01 03 2018 13 58 00 Document...

Страница 4: ...IEEE C37 94 2002 IEEE Standard for N times 64 Kilobit per Second Optical Fiber Interfaces between Teleprotection and Multiplexer Equipment describes a fiberoptic intra substation communication links b...

Страница 5: ...cond removable power supply available Dimensions and Weight Height 44 mm Width 222 mm without rack mount brackets Depth 228 mm from front to back connectors excluded Weight 1 4 kg The unit is intended...

Страница 6: ...4 Fiberoptic G 703 Codir IEEE C37 94 converter DC 60 00 7265 Fiberoptic G 703 Codir IEEE C37 94 converter AC 2 1 60 00 7268 Single Mounting Bracket 3 2 60 00 7270 Angle Bracket Kit Incl 8 screws 50 65...

Страница 7: ...5 Power cord AC connector IEC320 3 pin locking Single Mounting Bracket Screws for mounting brackets Angle Bracket Kit Optional extra removable Slim Power Module AC or DC...

Страница 8: ...ibersystem to identifythe product If the serial number is not noted on your delivery notes please add the serial number to your own product documentation This will be useful at future contact with Fib...

Страница 9: ...form one twisted pair Tx and Tx another twisted pair A Cat5 S FTP cable Shielded Foil Twisted Pair used for example in Ethernet communication is a good cable The outer shield is a braided mesh around...

Страница 10: ...osen by DIP switch at rear panel The channel is calculated by adding the lit LED s For example if LED 1 and LED 2 are lit 1 2 3 Channel 3 is chosen This means that data to from G 703 codir port is sen...

Страница 11: ...LED indicating that 21 216 receives G 703 codir 64kbit s protocol RxF Receives data on fiber A green LED indicating that 21 216 receives data in IEEE C37 94 format RxT Receives data on Twisted pair G...

Страница 12: ...ng serial number about your installation before contacting help desk Our technical support can be reached at Fibersystem AB G rdsfogdev gen 18A S 168 67 Bromma Sweden Telephone 46 8 564 828 80 Web htt...

Отзывы: