![Fiberstars WaterLevV IGW 6000 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/fiberstars/waterlevv-igw-6000/waterlevv-igw-6000_operation-and-maintenance-manual_2286791002.webp)
Thank you for purchasing the Industries newest and most technologically
advanced Pool / Spa water level monitoring devices on the market.
Your new Pool / Spa Water Level System is fully automatic. The system
incorporates several user alarms which indicate both Water Level or flow issues
and System monitoring such as Low battery monitoring and loss of water flow.
Please Read before Operation
The Sensor is mounted in the adjustable Bracket and allows for minor level
modifications.
The Sensor is located approximately 1 / 4 ” above desired Water level.
Low Water Level monitoring:
The WaterLevV System will automatically verify the Pool or Spa’s water level
every hour.
The system will automatically add water
in 5 minute intervals
whenever a low
level is detected.
High Water Level monitoring:
If an extended High Water Level
( more than 12 hours )
is detected the system
will alert you, a Back Wash or drain may be required to lower the water level.
If the High Level is minor, standard water dissipation over the following days will
automatically reset High Level alarm and the system will returns to normal status.
Low Battery Level detection:
The system automatically verifies the remaining Battery Power, and will alert
you when a Battery needs replacing.
( see Battery replacement procedure )
Water Flow monitoring:
The system automatically monitors Water Flow, If an extended loss of water
flow is detected a Flow Alarm will be triggered.
This alarm also may detect a leak in the Pool; an excessive number of Low Level
demands may indicate a leak.
Sensor LED definition as follows:
YELLOW
indicates a LOW LEVEL Detect
RED
indicates a HIGH LEVEL Detect
GREEN
indicates Send Data
Control Unit LED definition as follows:
LED No. 1
Indicates Power On Status
LED No. 2
Indicates Data Received
LED No. 3
Indicates Valve activation
LED No. 4
Indicates Low Battery Alarm ( 2 Beeps every 5 minutes )
LED No. 5
Indicates High Level Alarm ( 4 Beeps every 6 minutes )
LED No. 6
Indicates Water Flow Error ( Warble Tone every 7 minutes )
Control Valve Reset Switch definition:
Press Reset Button for 1 second to silence Alarms.
Press and Hold Reset Button for 3 second to Reset Alarms.
Battery replacement procedure:
Remove the battery cover located on the back of the sensor by removing the 4
Phillips screws.
Replace the Battery with a 9 V Alkaline Battery.
Replace Battery cover and insure gasket is seated correctly, make sure to install
all 4 screws.
( In the case of the loss of a screw spare screws are supplied in the Battery
compartment )
System Seasonal Power down procedure:
Remove the Sensor from the Bracket and store in a cool dry place until next
season.
While Sensor is removed from Bracket the Sensor is powered off to conserve
Battery life.
If you live in an area where Freezing is possible Disconnect and or shut off the
water source.
Maintenance:
If the system no longer maintains the water level, please check the following:
1. Water Inlet screen may be blocked with dirt or debris.
Solution:
Shut off the water source and remove Inlet connection, and then remove the
¾”
– ¾”
adapter. The Dirt screen is located in the Inlet port, remove, clean and
replace. Reconnect the water connection and turn on the water source.
* If Dirt Screen is not replaced damage to the valve may occur.
2. Lose of Power
Solution:
•
Verify that the Battery in Sensor is good ( 8.5 – 9 volt )
•
Verify that the Power Adapter is plugged and functioning
•
Power LED of the Valve Unit should be On
Rev. 7 08042009