background image

 

 

 

Front

 

Indicators

 

1

2

3

 

Figure

 

1WDM16

 

Front

 

Face

 

 

Health

 

 

Multi

function

 

indicator

 

displaying

 

overall

 

health

 

of

 

the

 

unit.

 

Color

 

indications

 

can

 

be

 

interpreted

 

using

 

the

 

following

 

table:

 

LED

 

State

 

Condition

Off

 

No

 

power

 

to

 

unit

 

Red

 

One

 

or

 

more

 

of

 

the

 

following

 

have

 

occurred:

 

 

Chassis

 

temperature

 

is

 

dangerously

 

high

 

 

shut

 

down

 

the

 

unit

 

or

 

increase

 

cooling

 

immediately

 

to

 

prevent

 

damage

 

 

Both

 

cooling

 

fans

 

are

 

not

 

functioning

 

properly

 

 

Hardware

 

failure

 

/

 

Self

Check

 

failure

 

Yellow

 

One

 

or

 

more

 

of

 

the

 

following

 

have

 

occurred:

 

 

Chassis

 

temperature

 

is

 

at

 

the

 

high

 

end

 

of

 

the

 

functional

 

limit

 

 

check

 

that

 

the

 

airflow

 

temperature

 

is

 

within

 

limits

 

and

 

that

 

it

 

is

 

not

 

restricted

 

 

One

 

of

 

the

 

cooling

 

fans

 

is

 

not

 

functioning

 

properly

 

Green

 

Temperature

 

is

 

within

 

range,

 

fans

 

are

 

working

 

properly

 

and

 

they

 

system

 

is

 

functioning

 

normally

 

 

PS1

 

 

Shows

 

status

 

indication

 

of

 

the

 

power

 

supply

 

in

 

PS

 

Slot

 

1

 

(top

 

slot).

 

Color

 

indications

 

can

 

be

 

interpreted

 

using

 

the

 

following

 

table:

 

LED

 

State

 

Condition

Off

 

No

 

power

 

supply

 

installed

 

Red

 

One

 

or

 

more

 

of

 

the

 

following

 

have

 

occurred:

 

 

Power

 

supply

 

temperature

 

is

 

dangerously

 

high

 

 

shut

 

down

 

the

 

unit

 

or

 

increase

 

cooling

 

immediately

 

to

 

prevent

 

damage

 

 

Input

 

power

 

is

 

present

 

but

 

output

 

is

 

out

 

of

 

range

 

 

replace

 

the

 

power

 

supply

 

Yellow

 

One

 

or

 

more

 

of

 

the

 

following

 

have

 

occurred:

 

 

Power

 

supply

 

temperature

 

is

 

at

 

the

 

high

 

end

 

of

 

the

 

functional

 

limit

 

limit

 

 

check

 

that

 

the

 

airflow

 

temperature

 

is

 

within

 

limits

 

and

 

that

 

it

 

is

 

not

 

restricted

 

 

No

 

input

 

power

 

is

 

present

 

 

check

 

the

 

AC

 

supply

 

 

Communication

 

to

 

chassis

 

cannot

 

be

 

established

 

 

replace

 

the

 

supply

 

Green

 

Temperature

 

is

 

within

 

range

 

and

 

the

 

power

 

supply

 

is

 

functioning

 

normally

 

 

PS2

 

 

Shows

 

status

 

indication

 

of

 

the

 

power

 

supply

 

in

 

PS

 

Slot

 

2

 

(bottom

 

slot).

 

Color

 

indications

 

can

 

be

 

interpreted

 

using

 

the

 

table

 

above.

 

Содержание WDM16

Страница 1: ...USER MANUAL Active Wave Division Multiplexer WDM16 WDM8A WDM8B...

Страница 2: ......

Страница 3: ...us the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall not be exposed to dripping or splashing No objects filled with liquids such as v...

Страница 4: ...I equipment must be earthed separately Grounding the unit is one of the measures for protection against electrical shock hazard dangerous body currents Hazardous voltage may not only be caused by defe...

Страница 5: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Страница 6: ...Active Wave Division Multiplexer Combines 16 or 8 optical channels into a single fiber pair Each channel independently supports data rates from 155 MB up to 3 GB SMPTE compatible internal fiber optics...

Страница 7: ...the number of Active Wave Division channels and the associated internal wavelengths that are supported The chassis dimensions and power supplies remain identical The WDM16 supports all of the 16 stand...

Страница 8: ...if there is mechanical damage or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier s inspection Chassis Mounting Mount the chassis using fastener...

Страница 9: ...ystem is functioning normally PS1 Shows status indication of the power supply in PS Slot 1 top slot Color indications can be interpreted using the following table LED State Condition Off No power supp...

Страница 10: ...INF 8074i more information later in this manual They are fixed bi directional ports and cannot support dual TX or dual RX SFPs Any standard MSA complaint SFP can be used in these slots including but n...

Страница 11: ...Power Supply Module AC Inlet Power is provided through a Neutrik powerCON TRUE1 connector Connect to 100 240 VAC power source using the supplied AC power cord Fuse Compartment Contains the fuse for th...

Страница 12: ...lete redundancy The second supply can be inserted at any time in the unused power supply slot Insert the supply first then apply external AC power The PSMAC and the WDM16 8 support hot swapping of the...

Страница 13: ...REMOVE CAP REPLACE FUSE SCREWDRIVER SLOT Figure 6 Replacing the Fuse in the PSMAC...

Страница 14: ...e SFP Module has a Bail Clasp close the Bail Clasp before inserting the SFP Module 4 With the gold finger connector on the bottom and the label on the top line up the SFP Module with the empty cage an...

Страница 15: ...Tab Pull the tab gently in a straight outward motion until it disengages from the port Make sure the tab is not twisted when pulling as it may become disconnected from the SFP Module Slide Tab With y...

Страница 16: ...nnecting the cable requires grasping the cable connector with your full hand and pulling back the release ring with your thumb and fore finger while pulling the connector straight out See Neutrik docu...

Страница 17: ...the WDM16 The pinouts of the connectors are as follows Connector Pin Function 1 Rx to the WDM 2 RX to the WDM 3 TX from the WDM 4 TX from the WDM A standard crossover RJ11 cable can be used to daisych...

Страница 18: ...gical conditions allowing the longer sequences of ones or zeros to pass without error The Fiberplex Technologies WDM16 and WDM8 Active Coarse Wave Division Multiplexer has Video Enhanced optics pre in...

Страница 19: ......

Страница 20: ...WDM16 Specifications 19 00 482 6 3 00 76 2 3 47 88 1 18 33 465 5 25 6 4 17 25 438 2 13 12 333 2 13 62 346 0 Figure 10 WDM16 8 Overall Dimensions...

Страница 21: ...ax Data Rate MB 155 3000 Recommended Jitter psec 40 Operating Voltage VDC 3 3 Maximum Current mA 350 Internal CDWM Optical Interfaces Min Typ Max Aggregate Optical Launch Level dB 1 0 1 Aggregate Rece...

Страница 22: ...n 286 mm 2 625 in 67 mm 1 25 in 32 mm 1 1 lb 0 5 kg SPECIFICATIONS AC POWER SUPPLY Min Typ Max Power Supply Input Voltage VAC 100 110 240 Input Frequency Hz 40 400 Power Factor 92 Output 1Voltage VDC...

Страница 23: ......

Страница 24: ...WDMUM 1401 18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100...

Отзывы: