 Optical Cutoff Switch Installation

3

Applic

ation N

ot

e

A tri-color LED next to each optical port indicates the status of data flowing through the 

port:

Table 1 - 

Status LED States

The Optical Cutoff Switch comes with a front panel designed to facilitate mounting 

in our 4 U, 19-inch instrument rack, RK-210.  The front panel measures 1.78 inches 

across and 6.82 inches tall.  Two captive screws in the upper and lower left-hand cor-

ners allow the user to mount the Optical Cutoff Switch in the instrument rack.

A 5-pin terminal block mounted on the rear panel of the Optical Cutoff Switch has con-

nection points for external power as well as input from the SecurLAN system.

Table  - 

Optical Cutoff Switch Rear Panel Pinout

Input power to the Optical Cutoff Switch is limited to 6-15 VDC, 10 mA.  If input voltage 

drops below 6 VDC, the normally-closed Optical Cutoff Switch opens, disrupting the 

optical data flow.  Input voltage over the 15 volt limit damages the switch.

Note:

 If the 15 volt maximum limit is exceeded, the status LEDs blink rapidly to warn 

the user.

o

peratIng

 p

rIncIples

The Optical Cutoff Switch is designed to pass optical data from the input connector to 

the output connector on its front panel.  Inside the Optical Cutoff Switch, the optical path 

from the input to the output connector is interrupted only by an internal optical switch.  

When +6-15 VDC power is applied to the Optical Cutoff Switch, the internal switch is in 

the “closed circuit” position and data is allowed to pass through uninhibited.  

Status LEDs

rear panel pinout

Input voltage limit

LED Color

Indication

Green

Data is transmitting through the 

primary port OK

Red

No data is transmitting

Amber

Data is transmitting through the 

alternate port OK

Pin

Description

1

+6 - 15 VDC input power

2

Ground

3

Input 1 (not used)

4

Input 2 (1 x 3 configuration only)

5

Input 3

Содержание SecurLAN

Страница 1: ...pting the flow of data through the compromised cable but certain configurations of the switch are also capable of re routing data to a secured cable Introduction The SecurLAN Optical Cutoff Switch is...

Страница 2: ...ed Figure 2 The Optical Cutoff Switch The Optical Cutoff Switch has 3 general configurations A 1x1 switch with one pair of direct input to output ports A 2x2 switch with a dual pair of direct input to...

Страница 3: ...low 6 VDC the normally closed Optical Cutoff Switch opens disrupting the optical data flow Input voltage over the 15 volt limit damages the switch Note If the 15 volt maximum limit is exceeded the sta...

Страница 4: ...the Input pin on the rear panel of the Optical Cutoff Switch Placing a ground on this pin shunts power away from the internal optical switch causing the internal switch to open and halt the flow of d...

Страница 5: ...er supply to Pin 1 of the Optical Cutoff Switch 2 Connect the negative lead of the power supply to Pin 2 of the Optical Cutoff Switch 3 Select a relay on the ORM to use for activating the Optical Cuto...

Страница 6: ...4 Optical Cutoff Switch Input Truth Table The maximum wiring distance between the power supply and the Optical Cutoff Switch is 15 meters 50 feet assuming 22 AWG 8 conductor shielded cable is used On...

Страница 7: ...SecurLAN Optical Cutoff Switch Installation Application Note Figure 4 Optical Cutoff Switch Wiring Diagram...

Страница 8: ...sing the Optical Cutoff Switch option with the SecurLAN system please contact Fiber SenSys sales or technical support team directly at 1 503 692 4430 or by email at info fibersensys com 2925 NW Alocle...

Отзывы: