FIBER SENSYS FD322 Скачать руководство пользователя страница 4

 
 
 

 


 

Another possible application for the FD322 as a cable break detector is to protect solar panels at a 
solar farm. Deploying the break detection design involves weaving the fiber loop through the solar 
panels. The cable is looped through the panels in a manner that the cable cannot be removed without 
being cut. In this type of application, the APU can be tuned so that it will not alarm when the optical 
fiber is shaken but will alarm when the fiber is broken.  
 
Figure 2 

 

 
To configure the FD322 to detect breaks only, first verify that the maximum loss in the fiber is less than 
5dB.

1

  

 
The FD322 APU has a built-

in loss calculator that functions as part of the unit’s calibration process. 

Using the 

FD322’s

 

custom 

Tuning Software

 to check the loss 

using the APU, execute the “CALIB” 

command within the software’s “Terminal Mode” as follows:  
 

1. 

Enter Terminal mode and type “CALIB” in all caps, then [Enter] 

2. 

Type “ML” and [Enter]  

3.  Verify that you are prepared to calibrate the processor 
4.  Shake the fiber for ten seconds and press the test button located under the LEDs on the 

corresponding channel of the unit 

5.  View and record the measured loss value and ensure it is below 5dB 

 
A more detailed description of the calibration process can be found on the 

FD322 Field Calibration 

Video

.  Please visit 

http://www.fibersensys.com/products/product-videos

.  Note: Product and training 

videos are available to registered users. Register at 

http://fibersensys.com/login-or-register

. 

 
 
 

1.  Typically installations <5km have less than 5dB loss. 

 

 

Отзывы: