![FIBARO Walli Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/fibaro/walli/walli_operating-manual_2286556030.webp)
30
confIguratIon
64.
Power reports for second channel – periodic
Only in Double Switch Mode
Description
This parameter defines reporting interval for
measured power. Periodic reports are indepen-
dent from changes in value (parameter 63).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
65.
Energy reports for first channel – on change
Description
This parameter defines minimal change (from
the last reported) in measured energy that re-
sults in sending new report.
Parameter size
2B
Default value
10 (0.1kWh)
Available
values
0 – reporting on change disabled
1-500 (0.01-5kWh, 0.01kWh step) – minimal
change
66.
Energy reports for first channel – periodic
Description
This parameter defines reporting interval for
measured energy. Periodic reports are indepen-
dent from changes in value (parameter 65).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 – periodic reports disabled
30-32400 (30s-9h, 1s step) – time interval
67.
Energy reports for second channel – on change
Only in Double Switch Mode
Description
This parameter defines minimal change (from
the last reported) in measured energy that re-
sults in sending new report.
Parameter size
2B
Default value
10 (0.1kWh)
Available
values
0 – reporting on change disabled
1-500 (0.01-5kWh, 0.01kWh step) – minimal
change
Содержание Walli
Страница 1: ...FIBARO WALLI DOUBLE SWITCH FGWDSEU 221 OPERATING MANUAL EN v1 0...
Страница 2: ......