Notification Command Class:
The device uses notification Command Class to report different events
to the controller (“Lifeline” group).
notification
Type
Event
Event Parameters
Power
Management
[0x08]
Over-load detected [0x08]
Over-current detected [0x06]
System
[0x09]
System hardware Failure
[0x03]
Device overheat
[0x01]
Protection CC:
Protection Command Class allows to prevent local or remote control of
the device.
Type of protection State
Description
Local
0
Unprotected
- The device is not pro-
tected, and may be operated normally
via the user interface.
Local
2
No operation possible
– button can
not change relay state, any other func-
tionality is available (menu)
RF (remote)
0
Unprotected
- The device accept and
respond to all RF Commands.
RF (remote)
1
No RF control
– command class basic
and switch binary are rejected, every
other command class will be handled
Meter Command Class:
Meter Type
Scale
Rate Type
Precision
Size
Electric
[0x01]
Electric_kWh
[0x00]
Import
[0x01]
2
4
Electric
[0x01]
Electric_W
[0x02]
Import
[0x01]
1
2