Содержание FGWPB-111

Страница 1: ... Removing the device 6 5 Operating the device 7 6 Power and energy consumption 9 7 Association 10 8 Z Wave range test 11 9 Z Wave specification 12 10 Advanced parameters 14 11 Specifications 20 12 Regulations 21 FIBARO WALL PLUG Type B FGWPB 111 O P E R A T I N G M A N U A L EN v1 0 ...

Страница 2: ...k between transmitter and receiver as a result the construction of the building could affect network s range negatively Every Z Wave network has its unique identification number home ID Multiple independent networks can exist in the building without interfering Transmission security of FIBARO System is comparable to wired systems Z Wave technology is the leading solution in smart home automation T...

Страница 3: ...multi color LED frame FIBARO Wall Plug is a remotely controlled plug in switch with the ability to measure power and energy consumption It uses a LED frame to visualize the current load and operating mode with color changing illumination Our smart plug makes it possible to control electrical devices in a convenient and maintenance free way 1 Description and features FIBARO Wall Plug is a fully com...

Страница 4: ...cated on the casing 4 Wait for the device to be added to the system 5 Successful adding will be confirmed by the controller 6 Plug a device you want to control into the Wall Plug 7 Test the device by turning it on and off using the button NOTE When powered the device will indicate Z Wave status with color of LED frame Green the device is already added to the Z Wave network Red the device is not ad...

Страница 5: ...otherwise 3 Set the main controller in Security non Security Mode add mode see the controller s manual 4 Quickly triple click the button located on the casing 5 If you are adding in S2 authenticated mode type in the device pin code underlined part of the public key available on the device or in the manual 6 Wait for the adding process to end 7 Successful adding will be confirmed by the Z Wave cont...

Страница 6: ...rame will glow green signaling being added removing is not necessary otherwise 3 Set the main controller into remove mode see the controller s manual 4 Quickly triple click the button located on the casing 5 Wait for the removing process to end 6 Successful removing will be confirmed by the Z Wave controller s message NOTE Removing theWall Plug from the Z Wave net work restores all the default par...

Страница 7: ...nce plugged into a mains sock et the device signals it with blink green added red not added Range of the Z Wave network signaled with color depending on type of communication or the lack of it only in range tester mode Menu position signaled with color assigned to position Ongoing software update signaled with cyan blinking Hardware fault state error in communication with radio chip device secured...

Страница 8: ...al can be achieved by the procedure of remov ing described in Add ing the device on page 5 i Controlling the Wall Plug with FIBARO Home Center controller The Wall Plug after successful adding is represented in the Home Center interface with two icons Device allows to turn on and off the device and displays current active power and cumulative en ergy consumption Disabling visual indicator Visual in...

Страница 9: ...s changing into a work or a heat The unit of active power is Watt W Electric energy energy consumed by a device through a time period Consumers of electricity in households are billed by sup pliers on the basis of active power used in given unit of time Most commonly measured in kilowatt hour kWh One kilowatt hour is equal to one kilowatt of power consumed over period of one hour 1kWh 1000Wh Reset...

Страница 10: ...s to control up to 5 regular or multichannel devices per an association group LifeLine group is reserved solely for the controller and hence only 1 node can be assigned Association linking devices direct control of other devices within the Z Wave system network e g Dimmer Relay Switch Roller Shutter or scene may be controlled only through a Z Wave controller NOTE 2nd association group commands are...

Страница 11: ...ulsing yellow the Wall Plug tries to establish a routed communication with the main controller through other mod ules repeaters Visual indicator glowing yellow the Wall Plug communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will be signaled with visual indicator pulsing green Visu...

Страница 12: ...CURITY 0x98 V1 SECURITY_2 0x9F V1 SUPERVISION 0x6C V1 YES METER 0x32 V3 YES APPLICATION_STATUS 0x22 V1 CONFIGURATION 0x70 V1 YES CRC_16_ENCAP 0x56 V1 NOTIFICATION 0x71 V8 YES PROTECTION 0x75 V1 YES FIRMWARE_UPDATE_MD 0x7A V4 YES BASIC 0x20 V1 YES 9 Z Wave specification Generic Device Class GENERIC_TYPE_SWITCH_BINARY Specific Device Class SPECIFIC_TYPE_POWER_SWITCH_BINARY Description represents the...

Страница 13: ...ol of the device Type of protection State Description Local 0 Unprotected The device is not pro tected and may be operated normally via the user interface Local 2 No operation possible button can not change relay state any other func tionality is available menu RF remote 0 Unprotected The device accept and respond to all RF Commands RF remote 1 No RF control command class basic and switch binary a...

Страница 14: ... before the power failure Default setting 1 Parameter size 1 byte 3 Overload safety switch This function allows to turn off the controlled device in case of ex ceeding the defined power Controlled device can be turned back on via button or sending a con trol frame By default this function is inactive Available settings 0 function inactive 10 18000 1 0 1800 0W step 0 1W power threshold Default sett...

Страница 15: ...orded or if chang es are insignificant By default reports are sent every hour Available settings 0 periodic reports inactive 30 32400 in seconds Default setting 3600 1h Parameter size 2 bytes 14 Periodic energy reporting This parameter defines time period between independent reports sent when changes in power load have not been recorded or if chang es are insignificant By default reports are sent ...

Страница 16: ...h value set in parameter 26 only if power exceeded value of parameter 21 2 send frame with value set in parameter 27 only if power dropped below value of parame ter 22 3 send frame in both cases Default setting 3 Parameter size 1 byte 24 SWITCH ON value On Off Button association group 2 The value of BASIC SET command frame sent to the devices associat ed in 2nd group On Off Button when turning the...

Страница 17: ... settings 1 general alarm 2 smoke alarm 4 CO alarm 8 CO2 alarm 16 high temperature alarm 32 flood alarm Default setting 63 all Parameter size 1 byte 31 Response to alarm frames This parameter defines how the Wall Plug will respond to alarms de vice s status change In case of values 1 or 2 the Wall Plug is operating normally and LED frame signals an alarm through time defined in parameter 32 or unt...

Страница 18: ...When set to 1 or 2 LED frame color will change depending on active power and parameter 40 Other colors are set permanently and do not depend on power consumption Available settings 0 illumination turned off completely 1 color changes smoothly depending on ac tive power 2 color changes in steps depending on active power 3 white 4 red 5 green 6 blue 7 yellow 8 cyan 9 magenta Default setting 1 Parame...

Страница 19: ...umination color in case of Z Wave alarm Available settings 0 illumination turned off completely 1 no change in color LED frame color is deter mined by settings of parameters 41 or 42 2 LED frame flashes red blue white 3 white 4 red 5 green 6 blue 7 yellow 8 cyan 9 magenta Default setting 2 Parameter size 1 byte ...

Страница 20: ...Inductive general purpose cosφ 0 75 0 8 15A Pilot duty cosφ 0 35 360VA Motor 373W Electronic ballasts 3A 1 5kV 80A 20ms NEMA 5 15 max load 15A Class I Micro gap relay switch μ 2 home and office use indoor only Z Wave 500 series chip 908 4 908 42 or 916 0 MHz up to 50m outdoors up to 40m indoors depending on terrain and building structure 32 104 F 2 3 x 2 3 x 2 inch 11 Specifications NOTE Radio fre...

Страница 21: ...fferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes and modifications not expressly approved by the manufactu rer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules Industry Canada IC Compliance Notice This device complies with Industry Canada li...

Страница 22: ...tion safety nor interfere a legal communication if an interference is found the service will be suspended until improvement is made and the interference no longer exists 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波輻射性 電機設備之干擾 Safety classification rating home and offic...