Fig. 2 - 

DS18B20 temperature sensor icon 

in the Home Center controller

The Door / Window Sensor offers a wide range of advanced 

settings. The parameters listed below are available in the 

Fibaro configuration interface.

In order to configure the Fibaro Door / Window Sensor (using the 

Home Center 2 controller) go to the device options by clicking on 

the icon: 

Next, select the device options tab.

Device parameters:

V Configuration

Parameter no. 1

Input IN alarm cancellation delay.

Additional delay after an alarm from input IN has ceased. The 

parameter allows user to specify additional time, after which the 

input IN alarm is cancelled once its violation has ceased.

Default value: 0

Available parameter settings: 0 – 65535 s

Parameter value: 2 [byte]

The Fibaro Door/Window Sensor may be operated using:

• Any System compatible controller (e.g. Home Center 2)

• Cellular phone (e.g. iPhone or phones from other manufacturers, 

  with the proper control application)

• PC, with the use of an Internet browser,

• Tablets (e.g. iPad)

• Using the TMP button, located inside the housing.

VII Door / Window Sensor operation

Alarm Frame Support.

The Fibaro System allows you to set the device’s reaction to alarms 

(reaction to SENSOR_ALARM_REPORT frame). The Fibaro 

Door/Window Sensor sends alarm frames of different types, 

depending on parameter's no. 5 settings. The user should declare 

type of alarm frame for each connected sensor. For example, for a 

smoke detector connected to IN input the user should declare the 

type 1–ALARM SMOKE frame (value of 1 should be entered), to 

ensure the remaining Z-Wave network devices recognize the 

information on smoke detector alarm correctly.

VI Additional Functionality

The Device does not react to a programmed transmitter:

• Make sure the maximum range has not been exceeded and there 

  are no obstacles along the signal path containing metal surfaces, 

  e.g. metal cabinets, Ferro concrete ceiling, load bearing walls, etc.

• Make sure the device is not in the learning mode.

• Alternately repeat the programming process.

VIII Procedure to be followed in case of interference

Association allows the Fibaro Door/Window Sensor to directly 

control another device in the Z-wave network, e.g. Dimmer, Switch 

(On-Off), Roller Shutter or trigger scenes (scene control is only 

possible via the Home Center 2 controller).

The Fibaro Door/Window Sensor supports three association 

groups.

Group I 

is assigned to input IN1 (and the magnetic sensor). 

Sending BASIC SET or ALARM command frames.

Group II 

is assigned to TMP button. Once the button is released, 

ALARM GENERIC frame is sent to associated devices.

Group III 

reports on the condition of the device, only one device 

may be assigned to the group (main controller, by default).
The Fibaro Door/Window Sensor allows for control over 5 regular 

devices and 5 multichannel devices per group, out of which 1 field 

is reserved for the network controller.

In order to add an association (with the use of the Home Center 2  

controller) go to device options by clicking this icon:

IV Association

NOTE!

Association allows for direct transmission of control 

commands between devices and takes place without 

the participation of the main controller. Owing to this 

mechanism the Door/Window Sensor may 

communicate with devices even if the main controller 

is completely destroyed, e.g. in the event of a fire.

i

Parameter no. 5

Type of control frame transmitted for association group 1, activated 

via IN input. The parameter allows you to specify the type of an 

alarm frame or to force control frames transmission (BASIC_SET)

Default value: 255 – BASIC SET

Available parameter settings:

– ALARM GENERIC frame

1

 – ALARM SMOKE frame

2

 – ALARM CO frame

3

 – ALARM CO2 frame

4

 – ALARM HEAT frame

5

 – ALARM WATER frame

255 

– Control frame BASIC_SET

Parameter value: 1 [byte].

Sensor used without a DS18B20 sensor, or used with a switch 

connected to IN input, will be represented by single icon. After the 

DS18B20 temperature sensor has been connected, temperature 

sensor icon will be displayed.

NOTE! 

If a temperature sensor icon is not displayed 

despite the fact the sensor itself has been 

connected, or if the temperature readings are 

incorrect, inspect the connections on the 1-wire 

bus, in particular the connection between sensor 

outputs and the line, and the total length of the bus 

wire which should not exceed 30m.

i

NOTE!

Any new association order given while any 

association commands are already being sent to 

devices, cancels previous one.

i

Parameter no. 3

Type of IN input.

Default value: 0 – INPUT_NC (Normal Close)

Available parameter settings:

0

 – INPUT_NC (Normal Close)

– INPUT_NO (Normal Open)

2

 – INPUT_MONOSTABLE

3

 – INPUT_BISTABLE

Parameter value: 1 [byte].

Parameter no. 7

Value of the parameter specifying the forced level of dimming/ope-

ning roller blinds when “switch on”/”open” commands are sent to 

devices from association group no.1.

In case of alarm frames an alarm priority is specified.

Default value: 255

Possible parameter settings: (1 – 99) and 255

Value of 255 makes it possible to activate a device. In case of the 

Dimmer module it means activating the device and setting it to the 

previously stored condition, e.g. when Dimmer is set to 30%, 

deactivated and then reactivated using 255 commend, it will be 

automatically set to the previous condition i.e. 30%.

Parameter value: 1 [byte].

Parameter no. 9

Deactivating transmission of the alarm cancelling frame or the 

control frame deactivating the device (Basic). It allows for disabling 

the function of deactivating the device and cancelling alarms for 

devices associated with IN input.

Default value: 0

Available parameter settings:

0

 – for association group no. 1 information is sent

1

 – for association group no. 1 information is not sent.

Parameter value: 1 [byte].

NOTE!

The parameter cancels alarms only. Information on 

alarm violation or activation commands for devices 

from association groups are always sent.

i

Parameter no. 13

Sending an alarm or control frame (for IN input, depending on 

parameter no.5 value), and TMP button alarm frame. The frame is 

sent in “broadcast” mode,  i.e. to all devices within range - 

information sent in this mode is not repeated by the mesh network.

Default value: 0

Available parameter settings:

0

 – IN and TMP Broadcast mode inactive,

1

 – IN broadcast mode active, TMP broadcast mode inactive

2

 – IN broadcast mode inactive, TMP broadcast mode active

– IN and TMP broadcast mode active

Parameter value: 1 [byte].

NOTE!

If the “broadcast” mode of information transmission 

is activated for a given channel, then transmission of 

information in “singlecast” mode, i.e. to devices 

assigned to the association group, for this channel is 

deactivated.

i

Parameter no. 14

Scene activation functionality.

Default value: 0

Available parameter settings:

0

 - functionality deactivated

1

 - functionality activated

The device offers the possibility of sending commands compatible 

with Command class scene activation. Information is sent to 

devices assigned to association group no. 3

Controllers such as the Home Center 2 are able to interpret such 

commands and based on these commands activate scenes, to 

which specific scene IDs have been assigned. The user may 

expand the functionality of a button connected to IN input by 

distinguishing the sequence of it being pushed. For example: 

double click would trigger the “goodnight” scene and triple click 

would trigger the “morning” scene. To fully use the possibilities 

offered by the parameter no.14 it is recommended to use a 

momentary or a toggle switch (parameter no.3).

Scene ID is determined in the following manner:

IN input:

Switch from “off” to “on” ID10

Switch from “on” to “off” ID11

Remaining IDs are recognized correctly if the value of parameter 

no.3 was set to 2

Holding down ID12

Releasing ID13

Double click ID14

Triple click ID15

Parameter value: 1 [byte].

NOTE!

Scene activation functionality may shorten the 

battery life, even by 25%.

i

Parameter no. 12

Sensitivity to temperature changes. The maximum acceptable 

difference between the last reported temperature and the current 

temperature read from the sensor. If the temperatures differ by the 

set value or more, a report with the current temperature value is 

sent to the device assigned to association group no. 3.

Default value: 8 [0,5oC]

Available parameter settings: 0 – 255 [0oC to 16oC] [32oF – 

60,8oF]

To set an appropriate parameter value use the following formula:

x = delta T x 16 - for Celsius

x = delta T x 80 / 9 - for Fahrenheit

x = parameter value

delta T – maximum acceptable temperature gradient in Celsius or 

Fahrenheit

If the value is set to 0:

- if the wake-up interval is set to 255 seconds, temperature report 

will be sent according to the interval,

- if the wake-up interval is set to over 255, temperature report will be 

sent each ca. 4 minutes.

Parameter value: 1 [byte].

Select the device options tab. Next specify which devices will be 

associated, and to which association groups. Sending of 

configuration commands to associated devices might take up to a 

few hours, depending on previous devices settings and the number 

of devices within the network.

IX Guarantee

This Device may be used with all devices 

certified with Z-Wave certificate and should be 

compatible with such devices produced by 

other manufacturers. 

Any device compatible with Z-Wave may be added 

to Fibaro system. 

i

FIBARGROUP 

FIBARO

In case of any technical questions contact customer service centre 

in your country.

www.fibargroup.com

1. The Guarantee is provided by FIBAR GROUP Sp. z o.o. 

(hereinafter "Manufacturer"), based in Poznan, ul. Lotnicza 1; 

60-421 Poznan, entered in the register of the National  Court 

Register  kept  by  the  District  Court  in  Poznań,  VIII  Economic 

Department of the National Court Register, no. 370151, NIP 

7811858097, REGON: 301595664.

2. The Manufacturer is responsible for equipment malfunction 

resulting from physical defects (manufacturing or material) of the 

Device for 12 months from the date of its purchasing.

3.  During the Guarantee period, the Manufacturer shall remove any 

defects, free of charge, by repairing or replacing (at the sole 

discretion of the Manufacturer) any defective components of the 

Device with new or regenerated components, that are free of 

defects. When the repair impossible, the Manufacturer reserves the 

right to replace the device with a new or regenerated one, which 

shall be free of any defects and its condition shall not be worse than 

the original device owned by the Customer.

4.  In special cases, when the device cannot be replaced with the 

device of the same type (e.g. the device is no longer available in the 

commercial offer), the Manufacturer may replace it with a different 

device having technical parameters similar to the faulty one. Such 

activity shall be considered as fulfilling the obligations of the 

Manufacturer. The Manufacturer shall not refund money paid for the 

device.

5.  The holder of a valid guarantee shall submit a guarantee claim 

through the guarantee service. Remember: before you submit a 

guarantee claim, contact our technical support using telephone or 

e-mail. More than 50% of operational problems is resolved 

remotely, saving time and money spent to initiating guarantee 

procedure. If remote support is insufficient, the Customer shall fill 

the guarantee claim form (using our website - www.fibargroup.com) 

in order to obtain claim authorization.

When the guarantee claim form is submitted correctly, the 

Customer shall receive the claim confirmation with an unique 

number (Return Merchandise Authorization -RMA).

6.  The claim may be also submitted by telephone. In this case, the 

call is recorded and the Customer shall be informed about it by a 

consultant before submitting the claim. Immediately after submitting 

the claim, the consultant shall provide the Customer with the claim 

number (RMA-number).

7. When the guarantee claim form is submitted correctly, a 

representative of the Authorised Guarantee Service (hereinafter as 

"AGS") shall contact the Customer. 

8.  Defects revealed within the guarantee period shall be removed 

not later than 30 days from the date of delivering the Device to AGS. 

The guarantee period shall be extended by the time in which the 

Device was kept by AGS.

9. The faulty device shall be provided by the Customer with 

complete standard equipment and documents proving its purchase.

10. Parts replaced under the guarantee are the property of the 

Manufacturer. The guarantee for all parts replaced in the guarantee 

process shall be equal to the guarantee period of the original 

device. The guarantee period of the replaced part shall not be 

extended.

Parameter no. 2

Status change signalled by LED

Default setting: 1

Available parameter settings:

0

 - LED turned Off,

1

 - LED turned On.

Parameter value: 1 [byte].

11. Costs of delivering the faulty device shall be borne by the 

Customer. For unjustified service calls, the Service may charge the 

Customer with travel expenses and handling costs related to the 

case. 

12.  AGS shall not accept a complaint claim only when: 

• the Device was misused or the manual was not observed,

•  the  Device  was  provided  by  the  Customer  incomplete,  without 

accessories or nameplate, 

• it was determined that the fault was caused by other reasons than 

a material or manufacturing defect of the Device  

• the guarantee document is not valid there is no proof of purchase, 

13. The Manufacturer shall not be liable for damages to property 

caused by defective device. The Manufacturer shall not be liable for 

indirect, incidental, special, consequential or punitive damages, or 

for any damages, including, inter alia, loss of profits, savings, data, 

loss of benefits, claims by third parties and any property damage or 

personal injuries arising from or related to the use of the Device.

14. The guarantee shall not cover:

• mechanical damages (cracks, fractures, cuts, abrasions, physical 

deformations caused by impact, falling or dropping the device or 

other object, improper use or not observing the operating manual);

• damages resulting from external causes, e.g.: flood, storm, fire, 

lightning, natural disasters, earthquakes, war, civil disturbance, 

force majeure, unforeseen accidents, theft, water damage, liquid 

leakage, battery spill, weather conditions, sunlight, sand, moisture, 

high or low temperature, air pollution;

•  damages  caused  by  malfunctioning  software,  attack  of  a 

computer virus, or by failure to update the software as recommen-

ded by the Manufacturer;

• damages resulting from: surges in the power and/or telecommuni-

cation network, improper connection to the grid in a manner 

inconsistent with the operating manual, or from connecting other 

devices not recommended by the Manufacturer.

• damages caused by operating or storing the device in extremely 

adverse conditions, i.e. high humidity, dust, too low (freezing) or too 

high ambient temperature. Detailed permissible conditions for 

operating the Device are defined in the operating manual;

• damages caused by using accessories not recommended by the 

Manufacturer

• damages caused by faulty electrical installation of the Customer, 

including the use of incorrect fuses;

• damages caused by Customer's failure to provide maintenance 

and servicing activities defined in the operating manual;

•  damages  resulting  from  the  use  of  spurious  spare  parts  or 

accessories improper for given model, repairing and introducing 

alterations by unauthorized persons;

• defects caused by operating faulty Device or accessories.

15. The scope of the guarantee repairs shall not include periodic 

maintenance and inspections, in particular cleaning, adjustments, 

operational checks, correction of errors or parameter programming 

and other activities that should be performed by the user (Buyer). 

The guarantee shall not cover natural wear and tear of the Device 

and its components listed in the operating manual and in technical 

documentation as such elements have a defined operational life.

16. If a defect is not covered by the guarantee, the Manufacturer 

reserves the right to remove such defect at its sole discretion, 

repairing the damaged or destroyed parts or providing components 

necessary for repair or replacement. 

17. This guarantee shall not exclude, limit or suspend the Customer 

rights when the provided product is inconsistent with the purchase 

agreement.