18
SPECIFICATIOnS
#16: Specifications
NOTE
Charger type: unit shall
be supplied by a source
certified as Limited
Power Source (LPS) as
defined in clause 2.5
of IEC60950-1 2nd edi-
tion + Amd. 1 + Amd. 2.
i
CAUTION
SELV power supply
(uSB supply) is used
only for battery charg-
ing. The device does
not operate the valve
during the charging.
!
Power supply:
Charging port:
Charger voltage (not included):
Minimum charger current
(not included):
Operating temperature:
Storage temperature
(standby mode)
Maximum water temperature:
Temperature measuring accuracy:
Regulator class:
Device Firmware Class:
Motor protection:
Actuator action:
Actuator stroke:
Purpose of control:
Construction of control:
Degree of protection by enclosure:
Classification of control according
to protection against electric shock:
Action type:
Control pollution degree:
Rated impulse voltage:
Dimensions
(Diameter x Length):
Eu Directive compliance:
3.7V Li-Poly battery pack
(non-replaceable)
micro-uSB
5V DC (±5%)
0.5A
0–40°C
-10–25°C
90°C
0.5°C (within 0–40°C range)
Type 1 class
A-grade
Impedance Protected
Linear variable position actuator
5mm
Operating control
Integrated control
IP20
Class III
type 1
pollution degree 2
330V (when connected to the uSB
power supply)
56 x 74 mm (without the adapter)
56 x 87 mm (with the adapter)
RoHS 2011/65/Eu
RED 2014/53/Eu