MANUFACTURE CONSTANTS
FUNCTION
Value
MAX TEMPERATURE PRIMARY
80°C
TIME OF PUMP FUNCTIONING IN ANTI-LOCK
10 sec
INTERVENTION TIME ANTI-LOCK PUMP
24H
TEMPERATURE ANTIFREEZE ON (only circulator)
7°C
TEMPERATURE ANTIFREEZE ON (heat exchanger ignition)
4°C
TEMPERATURE ANTIFREEZE OFF
20°C
SETPOINT AND PARAMETERS
FUNCTION
Default RANGE
HEATING SETPOINT
60°C
30 – 75 °C
FLOOR HEATING SETPOINT
30°C
10 – 40 °C
ROOM SETPOINT (with external probe present)
20°C
10 – 30
°C
PARAMETERS
FUNCTION
N°
Default
RANGE
EXTERNAL PROBE START UP
1
0
0 – 1
BUILDING COEFFICIENT OF DISPERSION
2
35
5 – 35 °C
HEATING POST CIRCULATION
HEATING
EXCHANGER CIRCULATION STARTING
4
5
30
0
1 – 180 sec
0 – 240 sec
TEMPERATURES
FUNCTION
N°
DELIVERY TEMPERATURE
t: “Ch”
EXTERNAL TEMPERATURE
t: “Ep”
OFFSET SETPOINT OF EXTERNAL PROBE
t: “Se”
SELECTION JUMPERS enable
Jumper
0 / 1
JP7
JP8
High temperature / Low temperature plant
Combi / Only Heating
MIN. IGNITION TEMPERATURE CIRCULATOR
6
30
0 – 50 °C
SPEED PUMP PWM OPERATION 10 4
1=400 l/h - 2=800 l/h - 3=1000 l/h - 4=1200 l/h