background image

data: 13/01/16

file: P1X_ing.doc

pag 9 di 11

START

END POSITIONING

FORWARD/BACKWARD

SLOW/FAST

DISPLAY2

START OUTPUT

NONE

AUX OUTPUT

KEY TO BE PUSHED

NONE

1

2

3

4

5

By pressing the  

E

  key  it is possible to go back to the inputs test; in order to leave the test function, press  

P

.

8. 

SETTING OF THE NUMBER OF CYCLES TO BE CARRIED OUT  (CYCL)

By number of cycles we mean the number of repetitions of the positioning programme. The automatic
functioning mode involves the possibility to repeat the selected programme.  By setting a number of cycles
greater than 1, once the last dimension of the positioning programme has been carried out, at the next
command by the work counter input the positioner restarts from the first dimension of the selected programme.

Содержание P1X

Страница 1: ...mes giving the possibility to manage for every dimension the number of parts that are to be processed in sequence as well as the number of cycle repetitions In order to optimize positioning accuracy there are some parameters that can counterbalance system inertia clearances and wear and tear of mechanical couplings Find below the other features characterising the instrument automatic semiautomatic...

Страница 2: ...e work number etc For the relevant connections see wiring diagram on page 10 Description of the front panel The display1 always displays the axis dimension whereas the other displays show different parameters as a function of the positioner status The function indicators show the currently selected function PROGRAMMING The keys used for programming are the following P Function choice programming E...

Страница 3: ...th encoder zero notch or zero micro to zero set or preset the dimension Manual zero setting or presetting By pressing the E key or by enabling the PRESET input in the terminal box it is possible to zero set or to carry out a presetting of the dimension as a function of what was set in the constant on page 7 Automatic zero setting or presetting zero research By enabling the START input in the termi...

Страница 4: ...er of memorised dimensions which must not exceed 99 for instance it is possible to create as ultimate limits either 99 programmes made by a single dimension or one single programme made by 99 dimensions The modification of the dimensions is protected by a password the password is requested through the display of letter P on display3 and of three zeroes the first one of them is blinking on display2...

Страница 5: ...nt is used for the applications that need cutting with material removal 2 PreStop The positioner stops the axis movement when it reaches the dimension amounting to the difference between the set dimension and the PreStop value This parameter enables to counterbalance the positioning inertia in systems with constant inertia It is advisable to enter the PreStop parameter after setting all the other ...

Страница 6: ...ing between 0 and 9999 milliseconds for all the motion reversing manoeuvres 11 Deviation dimension By setting this constant to a value differing from zero at the end of the positioning the instrument waits for the switchover from open to closed of the WORK COUNTER input to carry out an onward shifting of a dimension equal to the Deviation Dimension after that when a time equal to the Deviation Ret...

Страница 7: ...he zero research automatic cycle see on page 3 the zero setting presetting or zero research function Zero automatic research mode1 In the automatic zero setting function when the START key is pressed the slow backward motion of the axis is started searching for the zero input When the zero point is reached the axis motion continues for 2 seconds more and then stops and carries out the dimension pr...

Страница 8: ...n inch From tenth of mm to hundredths of an inch From mm to hundredths of an inch From mm to tenths of an inch From cm to hundredths of an inch From dm to inches Sexagesimal degrees with display in degrees and prime numbers Sexagesimal degrees with display in degrees 7 INPUTS OUTPUTS TEST TEST In order to have access to the test function it is necessary to enter the password 273 In the inputs test...

Страница 9: ... P 8 SETTING OF THE NUMBER OF CYCLES TO BE CARRIED OUT CYCL By number of cycles we mean the number of repetitions of the positioning programme The automatic functioning mode involves the possibility to repeat the selected programme By setting a number of cycles greater than 1 once the last dimension of the positioning programme has been carried out at the next command by the work counter input the...

Страница 10: ...cer wiring diagram AUX OUTPUT relay START FORWARD BACKWARD relais GND A A B B 12V 24 Vac 24VDC 230 Vac 115 Vac P1X2 P1X3 P1X1 P1X0 0 0 0 0 START input SLOW FAST relay NC SLOW Transducer wiring diagram 18 20 17 19 21 22 GND A B 12V A B GND A B Vcc Connection bidirectional encoder open collector NPN or push pull output NPN A B 12V A B GND GND A B Vcc PNP 19 22 20 18 17 21 Connection bidirectional en...

Страница 11: ...Line driver differential 12V Maximum counting frequency 100 KHz Operating procedure mode Semiautomatic Automatic Absolute line Manual Single positioning Test Possibility to create working programmes 99 steps of program memory with the possibility of specifying the number of pieces and the number of cycle repeats Data storage with the machine switched off by EEPROM memory Extractable terminal junct...