background image

MAT2_

Data: 15/01/18

file: MAT2_ing.doc

Rev:2

pag 5/7

Magnetic band

The band consists of a magnetized plastic ferrite strip with alternate magnetic poles, carried by a
ferromagnetic steel strip.  Mechanical protection of the plastic ferrite strip is supplied by a non magnetic steel
strip with tickness 0,2mm.
The magnetic band is assembled by sticking it with a biadhesive tape.  The surface has to be smooth, clean
and dry: is advisable to clean it with a degreasing product (isopropyl alcohol, ethyl alcohol, solvents, etc).  The
magnetic band has to be sticked holding the plastic ferrite side in the direction of the sensor, which means
the steel side leaned on the stand surface.  Fixed the magnetic band, to keep off damages due to abrasions
or grazes of the plasic ferrite strip, is advisable the appliance (always biadhesive) of the non magnetic
protection streep.
The optimal ambient temperature for stick the biadhesive tape is over 10°C.  The maximum adherence of the
tape works out after 48 hours (about) of the application and is kept between –10 and 80°C.

Electrical wiring

Brown

+24Vdc

Positive power supply

Green

GND

Negative power supply

Yellow

CK+

Clock+ SSI

Orange

CK-

Clock – SSI

White

D+

Data+ SSI

Purple

D-

Data - SSI

Grey

ZR

Zero input (PNP)

Black

DIR

Direction input (PNP)

Содержание MAT2

Страница 1: ...MAT2_ Data 15 01 18 file MAT2_ing doc Rev 2 pag 1 7 USER S MANUAL AND MAINTENANCE ABSOLUTE TRANSDUCER MAT2_ ABSOLUTE MAGNETIC BAND PA50 10 ...

Страница 2: ...essive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 UE Elettromagnetic Compatibility 2011 65 Rohs Maintenance The instrument does not needs a particular maintenance except cleani...

Страница 3: ...ice a sensor sensible to magnetic fields an electronic signals conversion circuit and an output stage The most importan feature is that this sensor always keeps the quota it means that is possible to move the sensor also without power supply and without loosing the quota There are available two inputs to define the zero setting and the direction The data exchanging is made through protocol SSI wit...

Страница 4: ...netic sensor is necessary to observe the quotas mounting on the following draws pay attention that the distance between the sensor and the magnetic band doesn t exceed 0 8 mm Alignement tolerance magnetic band transducer A color led indicator shows the following state 1 green transducer power on ok 2 red error condition ...

Страница 5: ...band has to be sticked holding the plastic ferrite side in the direction of the sensor which means the steel side leaned on the stand surface Fixed the magnetic band to keep off damages due to abrasions or grazes of the plasic ferrite strip is advisable the appliance always biadhesive of the non magnetic protection streep The optimal ambient temperature for stick the biadhesive tape is over 10 C T...

Страница 6: ...ings are the same If in one of the two cycles the value is corrupted by noise the two values will be different and the reading must be repeated The data is a 24 or 25 bit right aligned Binary or Gray coded Zero point setting After the transducer has been positioned on the magnetic band it is necessary to set the value to zero otherwise the minimum value can be any value within the admissible range...

Страница 7: ...ion Cable Ø6 6 PUR standard lenght 2 5 10m Output SSI RS422 Data output 24 bit Gray binary code optional parity 25 bit Gray binary code optional parity Clock SSI 32KHz 1 5MHz Protection degree IP66 Case Alluminium Working temperature 0 50 C Electromagnetic compatibility 2014 30 UE PA50 10 MAGNETIC BAND Length max 40 955 m Width 10 mm Thickness 1 7 mm Bending radius 75mm Linear thermal expansion co...

Отзывы: