background image

Display for magnetic band

F7

Data: 13/01/16

F7_ing.doc

pag 3/12

• The configurations provided in the manual are the only ones permitted.
• Do not try to use it anyway contrary to the indications provided.
• The instructions in this manual do not substitute but accomplish the obligations of the current
legislation regarding the safety laws.

Installation

Before installing the instrument, read the following warnings:
a) Connect the instrument strictly following the instructions of the manual.
b) It is the responsibility of the user to check, before using, the correct settings of the parameters of

the instrument to avoid damage to persons or things.

c) The instrument CANNOT function in a dangerous environment (inflammable or explosive).
d) The unit has sensible parts to electrostatic charge, therefore the handling of the inner electronic

cards has to be carried out with appropriate care to avoid permanent damages.

Description

The F7 is a display unit with integrated position sensor, in combination with the P50 magnetic
band, is a complete system to measure linear movements.
The display has five digits plus sign (range from -99999 up to +99999). The digits are 7.5mm high
to allow excellent readability also at a distance.
It is possible to select the counting direction, the number of decimal places, and the units (mm or
inches).  The displayed value can be corrected with a multiplication factor, with values between
0.001 and 99999.
The instrument can count in absolute mode or relative mode by pressing the corresponding
button. Also, it is possible to set a preset value which can be activated by pressing the
corresponding button.
The electronics are protected by a plastic housing which is robust, shock-resistant, and self-
extinguishing.
Two versions of the F7 are available:

  F7-E with external sensor

  F7-I with integrated sensor

The display can be fixed quickly and easily using the two threaded holes on the back of the
housing or alternatively with the SM bracket support or the SF flanged support which can be
supplied optionally.
The unit is powered by a ½AA 3.6V battery which lasts approximately 4 years and when the
battery is almost exhausted, an icon will appear to advise the operator to substitute it. This does
not effect the configuration parameters and also the correct measurement is maintained if the
magnetic band is not moved during this operation.

Programming

To step into the parameter programming press key     and on the display appears  

, now

press 2 times key 

RESET

 and appear 4 zeroes, the first on the right is blinking, with keys   (digit

increase) and  

 (digit selection), set out password 

0273 

and confirm with 

RESET

. In case of

wrong set-out of password  it goes out of the programming. The parameters that have to be set
can be run with key   and in order of appearance they are:

0

0

0

0

value to be displayed for 10mm of sensor displacement,

+%

+%

+%

+%

number of decimal digits,

//

//

//

//

keys opening mode

%.

%.

%.

%.

count direction,

To enter into the modification of the selected parameter press two times 

RESET

 (one time displays

only the value) and with keys    and  

 set the wanted value to be confirmed with 

RESET

.

 To go out of the programming press 

  .

0

0

0

0

Value to be displayed for 10 mm of sensor displacement

Содержание F7-

Страница 1: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 1 12 USER S MANUAL AND MAINTENANCE DISPLAY FOR MAGNETIC BAND WITH BATTERY POWER SUPPLY TYPE F7 ...

Страница 2: ...ow are some references to be followed for the storage of the instrument Avoid environments with excessive humidity and those exposed to bad weather avoid open areas Avoid putting the instrument directly on the ground Store the instrument in its original packing Conformity declaration and EC marking The instrument answers to the following Communitarian Directives 2014 30 EU Electromagnetic compatib...

Страница 3: ...ing the corresponding button Also it is possible to set a preset value which can be activated by pressing the corresponding button The electronics are protected by a plastic housing which is robust shock resistant and self extinguishing Two versions of the F7 are available F7 E with external sensor F7 I with integrated sensor The display can be fixed quickly and easily using the two threaded holes...

Страница 4: ...following VALUE ENTER RESET 0 Not active Not active Not active 1 mm inch conversion abs rel measurement Reset 2 Not active Not active Preset 3 Not active Not active Fast Preset 4 Not active Not active Change of origin 0 1 2 5 Not active Not active Offset 6 Not active Not active Fast Offset 7 Not active Not active Delayed reset after 3s 8 Not active Not active Delayed preset after 3s Delayed means ...

Страница 5: ...pressing ENTER RESET 2 6W 2 6W 2 6W 2 6W appears and by pressing two times ENTER RESET it is possible to set directly the value to be displayed use buttons and confirm with ENTER RESET This function is useful if it is necessary to correct often the displayed value Count direction Set out the count direction of the display range allowed 0 or 1 Adjustment of displayed value After the installation of...

Страница 6: ...ip mounting The magnetic strip P50 consists of a magnetized plastic ferrite strip with alternate magnetic poles of 5 mm pitch carried by a ferromagnetic steel strip Mechanical protection of the plastic ferrite strip is supplied by a non magnetic steel strip with thickness 0 2mm The magnetic strip is assembled by sticking it with a bi adhesive tape The surface has to be smooth clean and dry is advi...

Страница 7: ...or mounting The sensor has be mounted according to the following draw and keeping the indicated tolerances For the optimal system functioning its is necessary that the distance between the sensor and the magnetic band is not over 1mm of the useful stroke 3 3 3 M A X 1 ...

Страница 8: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 8 12 F7 E AM20 ...

Страница 9: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 9 12 F7 I AM20 ...

Страница 10: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 10 12 ...

Страница 11: ...Display for magnetic band F7 Data 13 01 16 F7_ing doc pag 11 12 ...

Страница 12: ...y IP67 sensor for F7 E only Sensor cable for F7 E only length 0 5 1 3 5 meters Material PUR Ø5 5mm suitable for movable wiring cable Sensor house for F7 E only alluminium black Gap sensor magnetic strip 1mm max Working temperature 0 50 C Relative humidity 35 85 Electromagnetic compatibility 2014 30 EU RoHS 2011 65 EU Manufacturer All communications to the manufacturer should be addressed to FIAMA ...