3.2 Mechanical Installation Details
The vibration switch must be fitted on the machine structure so that good transmission is ensured
from the likely source of excess vibration.
The vibration switch shall be firmly fixed in the vertical orientation shown in figure 1 to a vertical
surface of the vibrating machine using M5 fixings suitably resistant to vibration.
Figure 1: Mechanical installation to the surface of the vibrating machine
VERTICAL
124
51
Set Level Cap
Transport
Plug
M5 fixings
in the two
places
M5 fixings
in the two
places
M20 x 1.5
Cable
Entry Cap
Switch
Rating
Label