7
First Service Menu screen: GENERAL
GENERAL
Programming
Items
Factory set
Default
Programming Range
(display)
Notes
Tank Temp.
205°F/96°C
200 °F
|______________
[]
___|
140 208
Correction for high
altitude below
Temp Units
•
Temperature °F
°F
|___
[]
____________|
°F °C
Vol Units
•
Volume
US G
U S Gallons
|____
[]
__________________|
US G UK G L
US gallons differ from
UK (Imperial) gallons
Priority
•
Temperature
•
Volume
Volume is default
Change
|___________________
[]
__|
Temperature Volume
Refill rate: Slower”
Refill rate:” Quick”
ECO Mode
NORMAL
ECO Mode
|__
[]
____________________|
DIS TO 140 TO OFF
See chart below
*Refill rate TEMPERATURE may be slower at large volume dispense, and will stay closed to set temperature
ECO Mode option, screen definitions
“ECO” mode, or digital power economy control feature may be
activated to save energy in standby state.
If selected, after four hours of non-use—controls automatically
lower the tank temperature to 140°F/60°C, or can be selected to
turn heaters “OFF”
To restore set temperature:
Touch the screen to come out of ECO mode
All FETCO commercial hot beverage equipment have well
insulated hot water tanks to limit energy consumption.
Effective insulation increases equipment life and lowers
building HVAC costs. FETCO has the best energy savings of
all major suppliers.
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
0 0 205
212.0
96
100.0
500 152 205
211.0 96
99.5
1000 305 200
210.1 93
98.9
2000 610 200
208.1 93
97.8
2500 762 200
207.2 93
97.3
3000 914 200
206.2 93
96.8
3500 1067 197 205.3 92 96.3
4000 1219 195 204.3 91 95.7
4500 1372 194 203.4 90 95.2
5000 1524 194 202.4 90 94.7
5500 1676 193 201.5 89 94.2
6000 1829 192 200.6 89 93.6
6500 1981 191 199.6 88 93.1
7000 2134 190 198.7 87 92.6
7500 2286 188 197.8 86 92.1
8000 2438 187 196.9 86 91.6
8500 2591 185 196.0 85 91.1
HWB-2100
© 2015 All Rights
Reserved
ECO
Heating
Filling
Tank Set Temp. °F
140
ECO mode icon displayed
Unit is in ECO mode after being
idle for more than four hours
Set Tank Temp.
205 °F
|
_____________[]_
|
140 208
140
EXIT
OFF
TO activate ECO Mode:
FROM Operator access screen:
Press “140”
Содержание HWB-2105 XTS
Страница 3: ...3 Dimensions Utility Connections HWB 2105 DRG 1201 00015 00 HWB 2110 DRG 1201 00016 00...
Страница 14: ...14 Parts and Service drawings Drawing 1101 00201 229 217 00 HWB 2105 Complete Parts...
Страница 16: ...16 HWB 2110 Complete Parts Drawing 1101 00202 00...
Страница 18: ...18 HWB 2105 Hot Water Tank Drawing 1104 00072 78...
Страница 20: ...20...
Страница 24: ......
Страница 25: ......