Fetco E1251IN-1B140-PM110 Скачать руководство пользователя страница 5

Go to fetco.com for the latest versions of all information         

Page 5

      

User Guide & Operator instructions

   

P213

e0

 NOVEMBER 2021

 

Enter Programming 

Screens shown are for twin brewer.  Single brewer will not have menu A4-A6.   

There are seven menu groups-A-G .  See the following pages for the batch parameter definitions and all settings for the brewer

 

 

TO ENTER PROGRAMMING 

1-Turn brewer “OFF” from power switch 

2-Turn power switch to “ON” 

 

…Screen will initialize  and then 

 display digital process notifications 

 

3-After Initialization-Red “STOP” Lamp turns on 

4-Quickly press “STOP” button. 

 

        When brewer is In PROGRAMMING MODE 

      -the screen will display:

 

       

                         

|BATCH PRG| 

|A   

(or B-H)

   | 

-

Illuminated LED indicates active keypad positions 

 

See the following pages for batch parameter 

definitions and all settings for the brewer

 

 

 

 

 

Turn power OFF 

Turn power ON 

Wait for red LED 

And quickly press STOP 

button on front touch pane 

 

First screen will display 

for PROGRAMMING-A 

Scroll through main menu 

topics by pressing “STOP” 

button. 

Note: Only the left side buttons of a two sided brewer are used for programming

 

 

Programing Menu Layout 

 

 

 

 

A10 to A70 

 

B10-B40 

 

C10-C50 

 

D10-D90 

 

E10-E70 

 

F10-F120 

 

G1-G15 

 

H10-H11 

 

 

Batch Parameters 

 

General Settings 

 

Service Inputs 

 

Service Outputs 

 

Calibration 

 

Service Menu 

 

Counters 

 

Exit and Save 

 

 

 

 

 

 

 

 

 

 

A11 

Brew Volume 

B1 

Tank Temperature 

C1 

LLC Probe 

D1 

Heater SSR 

E1 

Ready Temp. Offset 

F1 

Firmware Ver. 

G1 

Filter Used 

H1 

Save Changes 

 

 

 

 

 

 

 

 

 

 

A12 

Brew Time 

B2 

Brew at Temp 

C2 

Basket Sensor 

D2 

Fill Valve 

E2 

LLC Sensitivity 

F2 

Bootloader Ver. 

G2 

Filter Life 

H2 

EXIT? 

 

 

 

 

 

 

 

 

 

 

 

A13 

Prewet Percent 

B4 

Show Tank Temp 

C4 

Tank Temperature 

D3 

Lt Brew Valve 

E3 

Slow Flow Compensate 

F3 

Select Model 

G3 

Filter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A14 

Prewet Delay 

B5 

Units of Temp 

C5 

USB Drive 

D4 

Rt Brew Valve 

E4 

Lt Brew Flow 

F4 

Option Bypass 

G4 

Counter Reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

A15 

Bypass Percent 

B6 

Units of Volume 

C6 

Keyboard Test 

D5 

Lt Bypass Valve 

E5 

Rt Brew Flow 

F5 

Option BB Lock 

G5 

Choose Counter 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A16 

Drip Delay 

B7 

Customer Name 

 

 

D6 

Rt Bypass Valve 

E6 

Lt Bypass Flow 

F8 

Backup to USB 

G10 

Brewer Volume 

[T]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A20 

Batch (2) Enabled 

B8 

Customers Name 

 

 

D7 

Lt Basket Lock 

E7 

Rt Bypass Flow 

F9 

Restore from USB 

G11 

Brewer Volume 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A21 

Brew Volume 

B9 

Demo Mode 

 

 

D8 

Rt BasketLock 

 

 

F10 

Restore Defaults 

G12 

LT Brews[T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A22 

Brew Time 

B10 

Eco Mode 

 

 

D12 

LCD Brightness % 

 

 

F11 

Error Log 

G13 

LT Brews 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A23 

Prewet Percent 

B11 

Eco Idle Time 

 

 

D13 

LED Brightness % 

 

 

F12 

Erase Error Log 

G14 

Rt Brews [T] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A24 

Prewet Delay 

B12 

Eco Idle Temp 

 

 

 

 

 

 

F13 

Service Phone# 

G15 

Rt Brews 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A25 

Bypass Percent 

B13 

Water Filter 

 

 

 

 

 

 

F14 

Override Lt BBS 

 

See page 12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A26 

Drip Delay 

 

 

 

 

 

 

 

 

F15 

Override Rt BBS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A30 

Batch (3) Enabled 

 

 

 

 

 

 

 

 

F16 

Override Lt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A90 

Copy Batch 

 

 

 

 

 

 

 

 

F17 

Override Rt BBL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A91 

Copy Batch: From 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A92 

PASTE: To 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top and middle batches are permanent  SEE BOX on the following page for all “A” menus

 

 

 

 

 

 

STOP BUTTON 

On/OFF switch 

located lower 

right on back of 

brewer 

 

  Batch Program 

  A 

STOP 

STOP 

 

CBS-1252 

ver     2.0.210317 

STOP 

STOP 

Содержание E1251IN-1B140-PM110

Страница 1: ...ide and Operator Instructions CBS 1251 CBS 1252 and CBS 1253 Extractor Plus Brewing System FETCO PLUS Commercial Beverage Equipment CBS 1251 CBS 1252 1 gallon brewer with FETCO 1 Gallon L4D dispensers...

Страница 2: ...5 30 minutes 4 minute brew time 1 30 minute drip delay 0 Bypass CBS 2153 2 gallon Factory default setting First batch 2 gal 6 30 minutes 5 minute brew time 1 30 minute drip delay 15 Bypass Second batc...

Страница 3: ...22 2 25 5 15 9 gal 60 4 liters 3 X 3 0 kW 208 240 3 3 G 6 8 9 0 19 3 22 2 23 9 gal 90 6 liters E1252US UB250 PM110 Selectable 1 or 3 phase Sold as 3 phase 2 X 5 0 kW 208 240 1 2 G 7 6 10 0 36 6 42 2...

Страница 4: ...tput Specifications All brewers have terminal block electrical utility connection 50Hz or 60Hz Configuration Codes Heater Configuration Voltage Phase Wires KW Amp Draw Brew Volume Hour E1253IN 3B330 P...

Страница 5: ...r SSR E1 Ready Temp Offset F1 Firmware Ver G1 Filter Used H1 Save Changes A12 Brew Time B2 Brew at Temp C2 Basket Sensor D2 Fill Valve E2 LLC Sensitivity F2 Bootloader Ver G2 Filter Life H2 EXIT A13 P...

Страница 6: ...BATCH A1 permanent BATCH A4 permanent BATCH A2 enabled by factory BATCH A5 enabled by factory BATCH A3 disabled by factory BATCH A6 disabled by factory The A menu is the most accessed menu It is for p...

Страница 7: ...during brew A2 00 BATCH ENABLED YES Active Middle and Bottom batches A2 3 5 6 Batch on or off Batches may be individually enabled rewritten or deactivated A2 10 Batch Volume 1 5 gal 6 8 liters 0 51 to...

Страница 8: ...emperature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 205 212 0 96 100 0 500 152 205 211 0 96 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762...

Страница 9: ...is 10 sec Toggle OFF or ON Press To Test D3 LT left Brew Valve Test Press to test Activates valve Default is 10 sec Toggle OFF or ON Runs valve to verify flow NOTE Have container under brew basket D4...

Страница 10: ...ACTUAL VOLUME X CURRENT SETTING NEW SETTING Left Brew Valve FR 0 95 0 80G to 1 09G PROGRAMMED VOLUME Right Brew Valve FR 0 95 0 80G to 1 09G Use this formula to determine the correct setting Set FR l...

Страница 11: ...id not refill within expected time Water flow too slow from main Water supply flow rate is too low External to brewer Watch for short potting during brew cycle Investigate cause of low flow rate Clogg...

Страница 12: ...olume through right valve CBS 1251 CBS 1252 G31 A Rt Brew Volume R G32 A Lt Bypass Cycles LT Left bypass valve operation on off Count Totalized cycles of valve operation CBS 1252 only G33 A Lt Bypass...

Страница 13: ...From SAVE screen Press button 2 to toggle to the SAVE YES screen To SAVE and EXIT Press button 1 to SAVE your changes and EXIT NOTE User Settings will be erased and overwritten to factory default set...

Страница 14: ...ner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petroleum based polis...

Страница 15: ...as possible 4 All beverage equipment must use a water filter A finishing carbon filter is preferred 5 Install the filter unit after a water shutoff valve and in a position to facilitate filter replac...

Страница 16: ...he unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or...

Страница 17: ...NDLE 1023 00180 00 BLUE PLUG BB HANDLE Stainless Steel Brew Basket Ref Part Number Description B001280B1 Complete Stainless Steel Brew basket no clips Standard B002280B1 Complete Stainless Steel Brew...

Страница 18: ...r the latest versions of all information Page 18 User Guide Operator instructions P213e0 NOVEMBER 2021 Parts Diagram CBS 1251 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Drawing 1101 00572...

Страница 19: ...9 00 WELDMENT FRONT COVER CBS 2250 27 1 1001 00402 00 COVER TOP CBS 2251 28 1 1001 00403 00 COVER UPPER BASE CBS 2251 29 12 1082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 30 1 1046 00035 00 L...

Страница 20: ...n Page 20 User Guide Operator instructions P213e0 NOVEMBER 2021 Parts Diagrams CBS 1252 and CBS 1253 6 Part Number1102 00471 00 ELECTRICAL COMPONENT LATTICE Parts lists for CBS 1252 1 1 2 gallon Drawi...

Страница 21: ...082 00017 00 SCREW TRUSS HD PHIL MACHINE 6 32 X 1 2 LG 30 1 1046 00035 00 LABEL WARNING TO REDUCE RISK OF ELECTRIC SHOCK OR FIRE 31 1 1402 00097 10 WIRE HARNESS CBS 1240 50 LOW AMP UNIVERSAL 32 1 1402...

Страница 22: ...IN VARISTOR 9 2 1081 00042 00 STANDOFF 1 4 HEX 10 1 1107 00010 00 HEATER ASSEMBLY IMMERSION 4kW 240VAC 10 1 1107 00032 00 HEATER ASSEMBLY IMMERSION 5kW 240VAC 11 2 1024 00053 00 LEVEL AND TEMP PROBE...

Страница 23: ...81 00042 00 STANDOFF 1 4 HEX 10 2 1107 00037 00 HEATER ASSEMBLY IMMERSION 2300W 240VAC 10 2 1107 00005 00 HEATER ASSEMBLY IMMERSION 3000W 240VAC 11 2 1024 00053 00 LEVEL AND TEMP PROBE GROMMET 12 1 10...

Страница 24: ...VARISTOR 9 4 1081 00042 00 STANDOFF 1 4 HEX 10 2 1107 00005 00 ASSEMBLY IMMERSION HEATER 3000W 240VAC 10 2 1107 00032 00 ASSEMBLY IMMERSION HEATER 5000W 240VAC 11 2 1024 00053 00 LEVEL AND TEMP PROBE...

Страница 25: ...GHT GROMMET 625 10 1 1023 00166 00 FITTING COLD WATER INLET GROMMET DESIGN 11 1 1107 00005 00 ASSEMBLY IMMERSION HEATER 3000W 240VAC 11 1 1107 00010 00 ASSEMBLY IMMERSION HEATER 4000W 240VAC 11 1 1107...

Страница 26: ...SCADE SPRAY DOME CBS 2050 60 S 5 2 1057 00076 00 VALVE ASSEMBLY COMPLETE NG DELTROL interchangeable with 1057 00078 00 5 2 1057 00078 00 VALVE ASSEMBLY COMPLETE NG RPE interchangeable with 1057 00076...

Страница 27: ...ions of all information Page 27 User Guide Operator instructions P213e0 NOVEMBER 2021 Wiring Diagrams SSR CBS 1251 PLUS Wiring diagram 1401 00196 10 SKU E1251US 1B230 PM110 heaters 2 X 3 0 kW SKU E125...

Страница 28: ...est versions of all information Page 28 User Guide Operator instructions P213e0 NOVEMBER 2021 SSR CBS 1251 Plus Wiring Diagram 1401 00197 10 SKU E1251IN 1B140 PM110 heaters 1 X 4 0 kW SKU E1251IN 1B15...

Страница 29: ...SR SSR L1 1 31 POWER L1 L2 L3 POWER L1 L3 THREE PHASE SINGLE PHASE L2 2 32 L3 3 33 L2 NOT CONNECTED L1 1 31 L2 2 33 L3 3 32 CBS 1252 V PlusWiring Diagram 1401 00197 10 SKU E1253US UB230 PM110 Heaters...

Страница 30: ...t versions of all information Page 30 User Guide Operator instructions P213e0 NOVEMBER 2021 SSR SSR CBS 1252 Plus Wiring Diagram 1401 00199 10 SKU E1252IN 1B230 PM110 heaters 2 X 3 0 kW SKU E1252IN 1B...

Страница 31: ...Guide Operator instructions P213e0 NOVEMBER 2021 SSR SSR SSR CBS 1252 PLUS CE Models SKU E1252IN 3B330 PM110 heaters3 X 3 0 kW 220 380 or 240 415 SKU E1252IN 3B340 PM110 heaters 3 X 4 0 kW 220 380 or...

Страница 32: ...End of section notes N...

Отзывы: