background image

Go to fetco.com for the latest versions of all information         

Page 11

     

Part A-User Guide & Operator instructions

 

P130 Part A Rev. 002 March 2016

 

 

OTHER

 

Programming Items  Factory set  Default

Programming Range (display)

 

Notes

 

Error Codes  

 Display Errors  

(Codes) 

1: 
2: 
3:

 

See Error Code Chart 

for references 

 

 Reset Errors  

(Reset) 

Reset

 

|_______________

[]

____| 

YES                NO

 

Factory and Service 

use only. Do Not Reset

NOTE 

)

Clear error codes by cycleing the brewer “OFF” then “ON”.   Do not reset the error codes.  Resetting 

error codes should be after completing the service and factory diagnostics and correcting any brewer faults 

Copy Program  

 From SD to B. 

SD

Æ

 Brewer 

SD

Æ

 Brewer

 

|________________

[]

____ 

YES                NO

 

Setup upload

 

---------------------------------------------------------------------------

Please insert SD card with 

the setup data!

 

 

 From B to SD 

Brewer

Æ

 SD 

Brewer

Æ

 SD

 

|________________

[]

____| 

YES                NO

 

Setup download 

Please insert an empty 

SD card with sufficient 

space (

2GB).  

SD card 

must be clear of files

 

Upload Logo  

 

Upload Logo  

UPLOAD LOGO 

Are you sure 

|________________

[]

____| 

YES                NO

 

Please insert SD card 

with logo file! 

Res to Factory 
& Select 
Brewer Type  

See next line: 

Select Brewer 

Configuration

  

Reset to default 

Reset to Default 

Are you sure 

|________________

[]

____| 

YES                NO

 

Completely overwrites 

all user setup, incl. 

user logo. 

Select Brewer 
Configuration 

CBS_2131 3L; CBS_2131 1G 

CBS_2132 3L; CBS_2132 1G 

CBS_2141; CBS_2142 

CBS_2151; CBS_2152 &2152-2G 

CBS_2161; CBS_2162 

Screen appears 
after pressing “Res 
to Factory”

 

..

[Above]

 

Select Model 

CBS [2131-2152]Series 

|________________

[]

____| 

Scroll to your 

brewer and tap 

ENTER tab 

Total Counters 

Counters 

 Display Counters 

    -OR- 

 Display 

Resettable 
Counters 

Counters 

Display Total 

Counters 

Left Brews 
Left Brew activated 
Left Brew [litr] 
Left Bypass activated 
Left Bypass [litr] 
Right Brews 
Right Brew activated 
Right Brew [litr] 
Right Bypass activated 
Right Bypass [litr] 
Fill valve Activated 
Fill Valve [litr] 
Heater Activated 
Heater “ON” time 

Touch To Return 














0:00 

 

Identical screen for  

Resettable Counters 

Will display when 
selected.  See next 
line to reset to zero 
 

NOTE: 

Total Counters

” is 

not user resettable 
 
See table, next 
page, for counter 
screen, definitions 

Reset Counters 

 

 Resets 

Counters  

Reset All 

Counters 

Reset All Counters 

Are you sure 

|________________

[]

____| 

YES                NO

 

Resetting will restart 

counter from zero 

Firmware  

 

Firmware 

Version 
-Software type

 

Display Firmware 
Version 

CBS_2132 [or model type] 

SW ver 3.0.12 

BL ver 1.1.3 

QP ver. 4.5.01 

Flash=512kb

 

Displays firmware 

version 

 

 Update 

Firmware  

UPDATE  

UPDATE

 

|________________

[]

____| 

YES                NO

 

Firmware upload

 

---------------------------------------------------------------------------

Please insert SD card with 

the firmware file!

 

DEMO Mode 

DEMO ON/OFF 

 

OFF

 

|________________

[]

____| 

ON                OFF

 

Demonstrates the controls for 

training. Disables all 

components in demo mode. 

 
 
 
 
 

 

ENTER

Содержание CBS-2142XTS

Страница 1: ...ctions FETCO Extractor Touch Screen Models CBS 2100XTS Two Part User Guide FETCO Extractor Touch Screen Models CBS 2100XTS Extractor Touch Screen Commercial Hot Beverage Equipment Table of Contents Pa...

Страница 2: ...cked Return to home screen First Brew I In ns st tr ru uc ct ti io on ns s f fo or r b br re ew w o op pe er ra at ti io on n f fa as st t b br re ew w Setup is simple 1 Connect unit to water and elec...

Страница 3: ...2 Ready Heating Filling Touch screen to unlock INFO STOP 04 44 INFO STOP 05 30 Regular 1 3 00 6 00 Regular 2 3 00 6 00 Decaf 1 3 00 6 00 Decaf 2 3 00 6 00 INFO STOP 05 30 1 Home screen activated twin...

Страница 4: ...to save changes and exit 7 The chart on the next page give the general service menu topics the pages following list the details of the topics When navigating up to EXIT leaves the Service Menu Screen...

Страница 5: ...OTHER Batch 1 Right Or Batch 1 Left Tank Temp Display Inputs Show Summary Error Codes Batch 2 Right Or Batch 2 Left Brew at Temp Calibrate Touch Screen Left Valve Copy Program Batch 3 Right Or Batch...

Страница 6: ...2 4 Batch 1 cannot be turned off Batch Name Regular 1 16 Choose from list Regular1 Regular 1 16 OR Write any name Models CBS 2130 CBS 2140 CBS 2150 CBS 2160XTS Batch Volume 0 80 to 3 00 gal 3L 1gal 3...

Страница 7: ...00 2591 185 196 0 85 91 1 X XT TS S E EX XT TR RA AC CT TO OR R T TO OU UC CH HS SC CR RE EE EN N CBS 2100XTS Ready Heating Filling Tank Temp 200 F Regular 1 1 00 5 30 Regular 2 1 00 5 30 Decaf 1 1 00...

Страница 8: ...ized Tank Temp 93 C Cal Touch Scr Calibrate Calibrate ________________ ____ YES NO If Yes Follow directions on the touch screen INPUT SUMMARY SCREEN Display Inputs See INPUTS Service Screen Brew Baske...

Страница 9: ...00 2800 1950 3800 Factory or service use for flow rate R Bypass Valve Test OR Calibrate If bypass option availble Right Bypass Valve Test Press to test TEST Press To Test Runs valve to verify flow Hav...

Страница 10: ...ces fl oz multiply by 29 57 to convert to milliliters After entering the measured volume exit PROGRAMMING and return to the normal screens 3 MANUAL METHOD Operator input CALIBRATE THE FLOW RATE Use th...

Страница 11: ...ion CBS_2131 3L CBS_2131 1G CBS_2132 3L CBS_2132 1G CBS_2141 CBS_2142 CBS_2151 CBS_2152 2152 2G CBS_2161 CBS_2162 Screen appears after pressing Res to Factory Above Select Model CBS 2131 2152 Series _...

Страница 12: ...me was more than 11 minutes after power up Water supply flow rate is too low Watch for short potting during brew cycle Investigate cause of low flow rate Clogged water filter 101 Error on refill Tank...

Страница 13: ...dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Carefully Follow the instructions supplied with the cleaning product 3 Never use spray cleaners solvent solvent based cleaner or petrol...

Страница 14: ...End of Section Notes...

Страница 15: ...etco com Installation and Service Guide For Qualified Service Technicians Only Models CBS 2140XTS Extractor Touch Screen Commercial Hot Beverage Equipment FETCO Touch Screen Models CBS 2140XTS One gal...

Страница 16: ...r installation notes CBS_2141XTS Single Field configurable Dual Voltage Three wire plus ground electrical Configuration Codes Heater Configuration Voltage Phase Wires Electrical Connection KW Amp Draw...

Страница 17: ...m 29lb 13 2kg 55 lb 25 kg 66 2lb 34 6 kg 3 3 gal 12 4 l 41 lb 18 6 kg 16 x 23 x 29 406 x584x737mm CBS 2142XTS Dual 1 gallon 34 873mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal 2...

Страница 18: ...Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all beverage equipment 4 Install the filter unit after a water shutoff valve and in a position to facilitate fi...

Страница 19: ...unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings 7 If the power cord requires repair or replacement it must be performed by the manufacturer or au...

Страница 20: ...to fetco com for the latest version of all information Part B page 6 P130 partB REV 002 Technical Supplement March 2016 Parts diagrams CBS 2141XTS Parts Drawing CBS 2141 XTS Drawing number 1101 00198...

Страница 21: ...TERNAL TOOTH LOCKWASHER 27 2 1082 00010 00 SCREW M4x10 ZINC PLATED PAN PHILLIPS MACHINE 28 1 1102 00243 00 ADAPTER ASSY 3 4 BSP x 1 4 NPT x 3 8 TUBE 29 1 1023 00147 00 PLUG TANK SERVICE DRAIN FOR 18GA...

Страница 22: ...GLE SHOT 240V 40A 8 4 1083 00009 00 WASHER 6 SCREW INTL TOOTH LOCKWASHER 9 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 10 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 11 2 1052 00033 00 RELAY SOLI...

Страница 23: ...083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC 7 3 1084 00006 00 NUT 8 32 18 8 HEX MACHINE SCREW 8 1 1044 00003...

Страница 24: ...Go to fetco com for the latest version of all information Part B page 10 P130 partB REV 002 Technical Supplement March 2016 CBS 2142XTS CBS 2142 XTS Drawing number 1101 00193 00...

Страница 25: ...00043 00 SOLENOID VALVE SINGLE 180 DEG 240VDC 26 2 1083 00005 00 WASHER M4 18 8 INTERNAL TOOTH LOCKWASHER 27 2 1082 00010 00 SCREW M4x10 ZINC PLATED PAN PHILLIPS MACHINE 28 1 1102 00243 00 ADAPTER ASS...

Страница 26: ...009 00 WASHER 6 SCREW INTL TOOTH LOCKWASHER 9 4 1084 00010 00 NUT HEX 6 32 UNDERSIZED ZINC PLATED 10 2 1003 00140 00 ALUMINUM BRACKET FOR SSR 11 2 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN...

Страница 27: ...IP 3 1 1083 00011 00 WASHER 8 SCREW SIZE INTERNAL TOOTH LOCK 4 2 1083 00016 00 WASHER 8 SCREW SIZE FLAT 5 1 1086 00008 00 CONNECTOR CABLE CLAMP 3 4 6 1 1058 00020 00 SWITCH PWR ROCKER RED ILLUM 250VAC...

Страница 28: ...15 16 x 3 32 5 Valve rebuild kit 1000 00098 00 Kit contains SPRING DIAPHRAGM PLUNGER Brew Basket Parts Complete Plastic Brew Basket STANDARD Part Number B014218BN2 CBS 2140XTS Part Number Plug Insert...

Страница 29: ...Go to fetco com for the latest version of all information Part B page 15 P130 partB REV 002 Technical Supplement March 2016 CBS 2141XTS WATER HANDELING LAYOUT...

Страница 30: ...Go to fetco com for the latest version of all information Part B page 16 P130 partB REV 002 Technical Supplement March 2016 CBS 2142XTS WATER HANDELING LAYOUT...

Страница 31: ......

Страница 32: ......

Страница 33: ...End of Section Notes...

Страница 34: ...End of Section Notes...

Отзывы: