Temperature Settings 

Parameter Name Range Default 

Comment 

7 Water 

Temp. 176

°

-

204

°

201

°

Inside tank. Will be slightly 
lower at spray head. To 
display in Celsius, see # 
58 in Advanced Settings. 

8 Hot 

Water 

Service 

Auto 
Off 
On 

ON 

Auto= Faucet will 

dispense only 
when not brewing. 

On=Faucet always 

enabled. 

Off=Faucet always 

disabled. 

9 Brew 

Temperature 
Protection 

On / Off 

On 

ON= Will brew only at set 

temperature. 

OFF= Will brew at any  

  temperature. 

Note: Changes will not 

take effect until the 
next brew cycle is 
complete. 

Содержание CBS-2021 e Series

Страница 1: ...800 338 2699 847 719 3000 techsupport fetco com www fetco com 2009 Food Equipment Technologies Company Part P109 REV 000 CBS 2021e Series Programming Guide...

Страница 2: ...Controls...

Страница 3: ...STOP button when the software version is displayed Example VER 32 A The STOP button is used to advance from one setting to the next It is illuminated green when in Programming mode The BREW buttons a...

Страница 4: ...OP button to go to the next parameter brew time Display 1 2 04 00 Repeat the last step until all parameters are programmed for batch 1 See the chart below for an explanation of each parameter Next bat...

Страница 5: ...change from ounces to liters see Advanced Setting 59 X 2 Brew Time Min Sec 01 30 05 00 04 00 X 3 Bypass Percent Off 30 Off Percentage of total brew volume X 4 Prewet Percent Off 25 Off Percentage of t...

Страница 6: ...elsius see 58 in Advanced Settings 8 Hot Water Service Auto Off On ON Auto Faucet will dispense only when not brewing On Faucet always enabled Off Faucet always disabled 9 Brew Temperature Protection...

Страница 7: ...Settings Diagnostics Loop back to start of batch programming ON Enter Advanced Settings Diagnostics Press STOP to continue Important After programming you must press and hold the HOT WATER button to...

Страница 8: ...rical resistance of the water in kilohms as measured between the water level probe and the tank If greater than 200 or if the tank is not full the display will read 51 Water Level Sensitivity LO HI LO...

Страница 9: ...ings to default factory settings 0 Do not reload defaults 1 Reload all defaults If 1 is selected you must advance to the next address for this change to take effect 58 Temperature Scale F or C F F Fah...

Страница 10: ...If 59 is oz 0 50 1 50 If 59 is LTR 44 1 30 Use this to compensate for minor discrepancies in actual volume versus programmed volume Set lower to increase volume higher to decrease volume FETCO EXTRACT...

Отзывы: