7
Please read the operating instructions and observe the safety precautions!
The specified illustrations can be found at the beginning of the operating instructions.
1
Technical data CT 11 E
Power consumption
350 - 1,200 W
Connected load to appliance plug socket max.:
EC
2,400 W
CH
1,100 W
GB
1,800 W
AUS
1,200 W
Volume flow (air) max., turbine
228 m
3
/h
Vacuum max., turbine
23,000 Pa
Volume flow (air), typical value in operation
160 m
3
/h
Vacuum, typical value in operation
18,000 Pa
Filter surface
14,000 cm²
Suction hose
ø 27mm x 35 m
Sound pressure level in compliance with DIN 45 635
72 dB(A)
Container capacity
15 l
Dimensions L x W x H
671 x 390 x 350 mm
Weight
11.5 kg
Power cable length
7.5 m
Protection type
IP X4
GB
2
Specified use
The vacuum cleaners are designed for use as
specified for the aspiration and evacuation of non-
noxious dusts, dirt, sand, shavings etc..
The vacuum cleaners are designed as specified
for vacuuming water.
The vacuum cleaners are designed in accordance
with EN 60335-1 and EN 60335-2-69 for a higher
loading in industrial use.
2.1 Safety instructions
- Use only accessories approved by Festool (see
the Festool Catalogue).
- Do not suck in any sparks or hot chippings.
- With the exception of wood dust, do not suck in
any flammable or explosive dusts such as
magnesium, aluminium etc.
Risk of explosion!
- Do not use to extract flammable or explosive
liquids (e.g. petrol, thinners).
Risk of explosion!
- Do not use to extract aggressive liquids (e.g.
acids, alkalis, solvents)
- Remove plug from mains socket when not in use
and before maintenance work.
- Do not pull plug out of mains socket by its cable.
- Protect the cable against heat, oil and sharp
edges.
- Do not leave devices out in the rain.
- Check the plugs and cables regularly and have
them replaced by an expert if damaged.
- Do not lift or carry the devices by their handles
using a crane hook or lifting gear.
- For safety reasons, only operate the machine
using a totally earthed socket.
3
Appliance preparation and initial
operation
3.1 Electrical connection
Caution!
The operating voltage shown on the rating
plate must correspond to the voltage of the mains
power supply. Make sure that the vacuum cleaner
is switched off when you plug the power cable in.
3.2 On/off switch (1.3)
In position 0 the vacuum cleaner is switched off and
the appliance plug socket (1.9) is dead.
Two modes of operation are possible:
a)
Switch position MAN:
The cleaner motor starts immediately.
The appliance plug socket is dead.
Switch position and suction hose diameter must
match.
b) Switch position Auto:
The appliance plug socket is live. The cleaner motor
starts only when the tool connected to the appliance
plug socket is switched on.
Caution!
Before turning the switch to the Auto
position, ensure that the tool connected to the
appliance plug socket is switched off.
Seen at Ideal Tools.