background image

1

About this document

This document only contains information on the assembly and installation of the enclosed individual
components. Application examples, information on implementing safety functions, commissioning and
operation are provided in separate documents.

1.1

Applicable documents

All available documents for the product 

è

 www.festo.com/pk.

Documents

Product, type

Contents

Catalogue inform-
ation

ISO cylinder, 
DSBG-...

Technical data

Instruction manu-
al

ISO cylinder with displacement
encoder 
DNCI-32-...

Operation

Instruction manu-
al

Control element, 
VAOH-P15-H13

Operation

Instruction manu-
al

Valve unit, 
VPCB-...-T22

Operation, installation

Instruction manu-
al

Connector-SET 
VABS-P15-S-B6

Assembly

Description

Controller, 
CECC-D- 

 

Operation

Brief description

Controller, 
CECC-D- 

 

Installation

Circuit diagram

Balancer kit, 
YHBP

Electrical and pneumatic interconnec-
tion

Installation
instructions

Plug, 
NECC-S1G9-C2-M

Assembly

Instruction manu-
al

Proximity sensor, 
SMT-8M-A-PS-24V-E-2,5-OE

Operation

Instruction manu-
al

Connecting cable, 
NEBC-M12G5-KS-LE5-CO

Operation

Catalogue inform-
ation

Connecting cable, 
KME-1-24DC-5-LED

Technical data

Tab. 1 Further applicable documents on the balancer kit

About this document

Festo — YHBP-1 — 2018-11

4

Содержание YHBP-1

Страница 1: ...8088702 YHBP 1 Balancer kit 8088702 2018 11 8088704 Instructions Assembly Installation...

Страница 2: ...Translation of the original instructions 2 Festo YHBP 1 2018 11...

Страница 3: ...4 Service 6 5 Product overview YHBP 7 5 1 Scope of delivery 7 5 2 Function 8 6 Transport 8 7 Assembly 9 8 Installation 10 8 1 Interfaces of valve unit VPCB T22 10 8 2 Pneumatic installation 11 8 3 In...

Страница 4: ...Instruction manu al Control element VAOH P15 H13 Operation Instruction manu al Valve unit VPCB T22 Operation installation Instruction manu al Connector SET VABS P15 S B6 Assembly Description Controlle...

Страница 5: ...ey Data Matrix Code of the product 2 Download documents from the Festo Support Portal by entering the order ID product key Data Matrix Code www festo com sp 3 Print out documents and keep together wit...

Страница 6: ...d and the manufacturer is not liable for damages 2 3 Foreseeable misuse Never use the product as follows With unauthorised modifications or alterations to the product With load limits exceeded In an i...

Страница 7: ...rol element VAOH 11 Tubing not in scope of delivery Fig 1 Product overview YHBP 5 1 Scope of delivery The kit only contains individual components that can be used for building a servo pneumatic balanc...

Страница 8: ...escription of the operating modes can be found in the application notes 1 1 Applicable documents 6 Transport Sequence of transport and unpackaging NOTICE Damage to the product due to incorrect transpo...

Страница 9: ...Applicable documents Attach the proximity sensor near the lower end position of the DNCI Tightening torque 0 6 Nm 3 Assemble the displacement encoder DNCI backlash free and parallel to the cylinder DS...

Страница 10: ...r direct pressure measurement on cylinder DSBG 6 Status LED 7 Power Error LED 8 Earth connection Fig 2 VPCB interfaces 2 Connection 2 G3 8 for working air balancer cylin der 9 Connection G1 8 for pneu...

Страница 11: ...ter 12 mm 2 Connect pressure gauge input connection 9 Bedienelement of valve unit VPCB with handle VAOH Tubing diameter 6 mm Tube length 0 5 m 10 m 3 Assemble the silencer not in scope of delivery as...

Страница 12: ...O interfaces X2 X3 X4 X5 6 CAN interface X6 7 Power supply for the I O interfaces X5 Fig 4 Interfaces CECC D BA The status LEDs show the operating status of the CECC D BA Status LED Meaning Run Applic...

Страница 13: ...mode X2 6 Reserved X2 7 Reserved X3 0 6 digital inputs System enable X3 1 X3 5 Can be configured by the user X4 0 8 digital outputs Operation enabled X4 1 Can be configured by the user X4 2 Shut off v...

Страница 14: ...ava Script and support of HTML5 Canvas e g Firefox Chrome Internet Explorer Version 9 Screen resolution 1280 x 768 pixels 8 4 Electrical installation WARNING Risk of injury due to electric shock For t...

Страница 15: ...4 WH CAN_H 1C 7 5 BU CAN_L 1C Manifold block BUS IN 2 24 V logic 2V 9 GND logic GND 3 2C Cable 2 wire 2C Manifold block BUS OUT 1 Colour code in accordance with IEC 60575 1983 01 Tab 5 Pin allocation...

Страница 16: ...that serves as a reference sensor as follows SMT 8M A PS 24V OE CECC D BA Wire colour1 Function Connection BN 24 V DC supply 24 V load BK Switching output Digital input X2 3 BU GND 24 V GND 1 Colour c...

Страница 17: ...sis must be carried out and all appropriate measures implemen ted Commissioning is dependent on the customer specific application During commissioning observe the associated documentation for the indi...

Страница 18: ...unctions The display and elimination of malfunctions are dependent on the customer specific application During operation observe the associated documentation for the individual components installed 1...

Страница 19: ...80 200 Travel speed m s 1 Operating voltage DC V 21 6 26 4 Duty cycle 100 Residual ripple 5 Operating pressure bar 4 8 Operating medium Compressed air to ISO 8573 1 2010 6 4 4 Lubricated operation no...

Страница 20: ...ization is prohibited Offenders will be liable for damages All rights reserved in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG 73734 Esslingen Ruiter S...

Отзывы: