background image

Solenoid valve 
VZWP-L-M22C

Festo AG & Co. KG

Postfach
73726 Esslingen
Deutschland
+49 711 347-0
www.festo.com

Operating instructions

8065870
1611a
[8065872]

Original: de

Solenoid valve VZWP-L-M22C

English

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Design

3

7

aJ

1

aA

6

2

5

4

8

9

1

Port 1: Input

2

Valve body

3

Electrical plug connector with seal
and mounting screw

4

Knurled nut

5

O-ring

6

Solenoid coil

7

O-ring

8

Armature guiding tube

9

Port 2: Output

aJ

Arrow for flow direction

aA

Thread for mounting bracket

Fig. 1

2

Function

The solenoid valve VZWP–L–M22C is a servo controlled
2/2-way valve with solenoid coil.
The solenoid valve VZWP–L–M22C is closed when de-ener­
gised (Normally Closed - NC). When power is supplied, the
differential pressure is relieved from the secondary side of
the piston via the servo hole. The effective differential pres­
sure lifts the piston away from the valve seat.

Fig. 2

The pilot function of the valve actuator can be used to control high pressures with
large nominal diameters by means of small solenoid coils.
The minimum differential pressure must always be present to ensure smooth func­
tioning of the servo control (

è

 Technical data).

3

Application

Solenoid valves of the series VZWP–L–M22C are intended to control the flow of
gaseous and fluid media in rigid piping systems.
 The product may only be used in its original state without unauthorised modific­

ations. Only the mounting and commissioning activities described in these oper­
ating instructions are permissible. Do not open the valve body or dismantle the
armature guiding tube.

 Do not use the product in closed circuits.
 Do not use the VZWP solenoid valve as a safety component.
 Use the product only in perfect technical condition.
 Only use media in accordance with specification. Before using other media,

please contact our customer support.

 Operation with chemically unstable gases, abrasive media and solids is imper­

missible.

 Use the solenoid valve only in the marked flow direction.

Return to Festo

Hazardous substances can endanger the health and safety of personnel and cause
damage to the environment. To prevent hazards, the product should only be re­
turned upon explicit request by Festo.
– Consult your regional Festo contact.
– Complete the declaration of contamination and attach it to the outside of the

packaging.

– Comply with all of the legal requirements for the handling of hazardous sub­

stances and the transport of dangerous goods.

4

Product variants

Features

Type code

Description

Type

VZWP

Solenoid  valve, servo  controlled

Valve type

L

In-line valve

Valve function

M22C

2/2-way valve, normally closed (NC)

Connection to valves and fittings

G14 to G1

Pipe thread per DIN ISO 228

N14 to N1

NPT pipe thread per ANSI B 1.20.1

Nominal size (DN)

130
250

13 mm
25 mm

Sealing material


V

NBR
FPM

Nominal voltage

1
2A
3A

24 V DC
110 V AC (50-60 Hz)
230 V AC (50-60 Hz)

Electrical connection

P4

Plug socket, 3-pin

Operating pressure

40

Max. 40 bar

Fig. 3

5

Transport and storage

 When shipping used products: Comply with all legal requirements for handling

hazardous substances and transporting dangerous goods. 
For return to Festo 

è

 Kapitel 3.

 Store the product in a cool, dry, UV- and corrosion-protected environment.

6

Installation

Note

 Installation only by qualified personnel.
 Avoid contamination. In this way you will prevent small holes from becoming

blocked (e.g. servo hole) and restriction or blockage of the function.

 Avoid mechanical stresses especially on the solenoid coil and the armature

guiding tube.

 Ensure sufficient thermal circulation at the installation location.

1. Before installation, check the system requirements:

– The tubing system is unpressurised and does not hold any medium.
– The pipelines are clean.
– The ends of the pipelines are mounted.
– The power supply is switched off.

2. Put the solenoid valve in its mounting position. Please note the flow direction.

The permissible flow direction is marked by an arrow on the valve body.

3. Screw the ends of the pipelines to the valve ports. Observe the permissible

tightening torques.

4. Establish the electrical connection. Use only the specified plug type (

è

 Tech­

nical data).
– Connect the electrical cable to the plug connector.
– Attach the seal to the electrical contacts.
– Plug in the plug connector and secure it in place with the mounting screw

(torque 0.3...0.5 Nm).

5. Connect the power supply.

Отзывы: