16
Festo — VPPI-...-S1BT — 2021-11
Commissioning
Parameter
Contents
Description
‘Firmware version’
e.g. V4.4.0
The firmware version of the connected valve
‘Electrical interface’ ‘Voltage’/‘Current’
Indicates whether the analogue interfaces of the
valve communicate via voltage (0 … 10 V DC) or
current (0 … 20 mA). This parameter can be set
for offline configuration. This parameter cannot be
changed when a valve is connected.
‘Pressure type’
e.g. 0 … 10 bar
The pressure range of the connected valve. This
parameter can be set for offline configuration. This
parameter cannot be changed when a valve is con-
nected.
‘Normal position’
‘Normally open’/‘Nor-
mally closed’
Normal position of the connected valve.
This setting is hardware-specific and cannot be
changed.
‘Nominal width’
e.g. 5
Nominal width of the connected valve.
This setting is hardware-specific and cannot be
changed.
‘PIN’
e.g. 327891
6-digit PIN with which the valve can be protected.
This PIN is requested when connecting to the valve.
The plug-in cannot connect to the valve without
the correct PIN. There is no PIN query with setting
000000. The PIN can be reset using a "clip grip".
This requires pressing the two outer control buttons
for control response simultaneously for 1 s
‘Valve name’
e.g. VPPI-...-S1BT
Bluetooth name of the valve. The valve uses the
name "VPPI_ [set name]" to establish the Bluetooth
connection.
‘Enable connect
sound’
–
Setting for whether a sound should be generated
when establishing or disconnecting the Bluetooth
connection.
‘Identification
sound’
–
The connected valve will beep and the LEDs will
flash.
Tab. 8: ‘Configuration’